Description
The biocompatibility of the diamond films were investigated with whole human blood samples. Blood used in this study was drawn from 10 healthy human patients of different age, sex, and blood group. A 2 ml samples were collected into standard tubes with EDTA anticoagulation agent. Blood was used within 6 hours from the collection time. A reference blood smear was conducted as a control sample before further experiments. Peripheral blood smears were performed on diamond thin films. The smears were analyzed within 15 minutes, with the use of a bright field microscope (Nikon Eclipse 80) with a 1000x magnification using an immersion objective.
The investigated samples:
0k - nanocrystalline diamond layers
2.5 k - boron-doped nanocrystalline diamond layer (level 2.5 k during PVD)
5k - boron-doped nanocrystalline diamond layer (level 5 k during PVD)
7.5k - boron-doped nanocrystalline diamond layer (level 7.5 k during PVD)
10k - boron-doped nanocrystalline diamond layer (level 10 k during PVD)
Dataset file
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
where a single part of the file is 512 MB in size.Example script for calculation:
https://github.com/antespi/s3md5
File details
- License:
-
open in new tabCC BY-NCNon-commercial
- Raw data:
- Data contained in dataset was not processed.
Details
- Year of publication:
- 2020
- Verification date:
- 2021-12-14
- Creation date:
- 2015
- Dataset language:
- English
- Fields of science:
-
- Automation, electronic and electrical engineering (Engineering and Technology)
- biomedical engineering (Engineering and Technology)
- DOI:
- DOI ID 10.34808/cwws-ct69 open in new tab
- Ethical papers:
- This study was approved by the Bioethics Committee of the Medical University of Lublin according to the Guidelines for Good Clinical Practice on 20th December 2012 (protocol no. KE-0254/293/2012).
- Verified by:
- Gdańsk University of Technology
Keywords
References
- publication Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
- publication Haemocompatibility of Modified Nanodiamonds
- publication Measurement of complex refractive index of human blood by low-coherence interferometry
- publication Optical Investigation of Hematocrit Level in Human Blood
- publication Optimization of a Fabry-Perot Sensing Interferometer design for an optical fiber sensor of hematocrit level
- publication Blood equivalent phantom vs whole human blood, a comparative study
- publication Nitrogen-Doped Diamond Film for Optical Investigation of Hemoglobin Concentration
Cite as
Authors
Version this document has several versions
-
version 1.4release date 2021-12-14
-
Current versionversion 1.3release date 2021-12-14
-
version 1.2release date 2021-12-14
-
version 1.1release date 2021-09-10
-
version 1.0release date 2020-12-17
seen 114 times