The dataset contains the magnetic field measurement results that are part of a comprehensive study on the assessment of the magnetic field emissions onboard of the research-training vessel. The measurements were carried out, nearby the bow thruster motor fed from the inverter, during maneuvering and the sea voyage.
The bow thruster is assembled in the forepart of the ships’ hull and has constant pitch propeller. Using the control levers at the wings of the bridge, it is possible to change the speed and direction of the revolutions of the propeller, and in this way to move the bow of the ship during maneuvering. The bow thruster is driven with a squirrel cage asynchronous motor fed by the PWM frequency converter. The IGBT (Isolated Gate Bipolar Transistor) inverter was operating at 2 kHz (possible 4 kHz) switching frequency. The inverter output frequency was adjusted in the frequency range from 0 to 50 Hz. Measurements were performed in the bow thruster compartment with the ESM-100 H/E field meter, which was fixed on the wooden bar, about 1 m from the bow thruster motor (Figure 1).  

Data recording of magnetic field emissions was carried out with a/d converters of the data acquisition board (DAQ), which were connected to the analog outputs of an isotropic field meter (Figure 2). ESM-100 H/E field meter, which was applied in this system, enables the measurements of a magnetic field induction in the measuring ranges from 1 nT to 20 mT. Four wide-band analog outputs of this meter afford possibilities for measuring the time waveforms of the magnetic fields, separately in the three orthogonal directions, in the output voltage range from 0 to 600 mV (see Table). The measured analog signal is conditioned with the use of National Instruments sub-assemblies. The initial conditioning follows and is realized through the low-pass filter module (for antialiasing application) with programmable cut-off frequency. The applied module has 8th-order elliptic filters, which provide a very sharp roll-off. Matching of the signal level to the a/d converter the DAQ input is realized by the input amplifier with the programmable gain. The formation of the output digital signal from the analog signal takes place in the a/d converter with a 16-bit resolution and sampling rate equal to 20 kS/s. Discrete signals are next analyzed (off-line) with the use of virtual instruments (LabVIEW software).

Illustration of the publication

Figure 1. The ESM-100 H/E field meter located close to the bow thruster motor

Figure 2. A block diagram of the measuring system for assessment of magnetic field emissions

Dataset file

bow thruster.zip
30.8 MB, S3 ETag 45b70bcbe27bba30ed5e9f602bf898c7-1, downloads: 75
The file hash is calculated from the formula
hexmd5(md5(part1)+md5(part2)+...)-{parts_count} where a single part of the file is 512 MB in size.

Example script for calculation:
https://github.com/antespi/s3md5
download file bow thruster.zip

File details

License:
Creative Commons: by 4.0 open in new tab
CC BY
Attribution
Raw data:
Data contained in dataset was not processed.

Details

Year of publication:
2020
Verification date:
2020-12-17
Creation date:
2007
Dataset language:
English
Fields of science:
  • Automation, electronic and electrical engineering (Engineering and Technology)
DOI:
DOI ID 10.34808/beh9-bq90 open in new tab
Verified by:
Gdańsk University of Technology

Keywords

References

Cite as

seen 184 times