Details
- Financial Program Name:
- OPUS
- Organization:
- Narodowe Centrum Nauki (NCN) (National Science Centre)
- Agreement:
- UMO-2017/27/B/ST8/02518 z dnia 2018-08-08
- Realisation period:
- 2018-08-08 - 2023-08-07
- Project manager:
- dr hab. inż. Izabela Lubowiecka
- Team members:
-
- Co-investigator prof. dr hab. inż. Czesław Kazimierz Szymczak
- Co-investigator dr inż. Katarzyna Szepietowska
- PhD Student Daniil Reznikov
- PhD Student mgr inż. Bartosz Borzeszkowski
- co-investigator Mateusz Troka
- Co-investigator dr hab. inż. Agnieszka Tomaszewska
- Principal Investigator dr hab. inż. Izabela Lubowiecka
- PhD Student Szymon Kalinowski
- Realised in:
- Structural Mechanics Department
- External institutions
participating in project: -
- Gdański Uniwersytet Medyczny (Poland)
- Project's value:
- 1 166 680.00 PLN
- Request type:
- National Research Programmes
- Domestic:
- Domestic project
- Verified by:
- Gdańsk University of Technology
Papers associated with that project
Filters
total: 12
Catalog Projects
Year 2024
-
Self-organising maps in the analysis of strains of human abdominal wall to identify areas of similar mechanical behaviour.
PublicationThe study refers to the application of a type of artificial neural network called the Self-Organising Map (SOM) for the identification of areas of the human abdominal wall that behave in a similar mechanical way. The research is based on data acquired during in vivo tests using the digital image correlation technique (DIC). The mechanical behaviour of the human abdominal wall is analysed during changing intra-abdominal pressure....
Year 2023
-
Biomechanical causes for failure of the Physiomesh/Securestrap system
PublicationThis study investigates the mechanical behavior of the Physiomesh/Securestrap system, a hernia repair system used for IPOM procedures associated with high failure rates. The study involved conducting mechanical experiments and numerical simulations to investigate the mechanical behavior of the Physiomesh/Securestrap system under pressure load. Uniaxial tension tests were conducted to determine the elasticity modulus of the Physiomesh...
-
Full-field in vivo experimental study of the strains of a breathing human abdominal wall with intra-abdominal pressure variation
PublicationThe presented study aims to assess the mechanical behaviour of the anterior abdominal wall based on an in vivo experiment on humans. Full-field measurement of abdominal wall displacement during changes of intra-abdominal pressure is performed using a digital image correlation (DIC) system. Continuous measurement in time enables the observation of changes in the strain field during breathing. The understanding of the mechanical...
Year 2022
-
A novel in vivo approach to assess strains of the human abdominal wall under known intraabdominal pressure
PublicationThe study concerns mechanical behaviour of a living human abdominal wall. A better mechanical understanding of a human abdominal wall and recognition of its material properties is required to find mechanically compatible surgical meshes to significantly improve the treatment of ventral hernias. A non-invasive methodology, based on in vivo optical measurements is proposed to determine strains of abdominal wall corresponding to...
-
Combined numerical and experimental approach to determine numerical model of abdominal scaffold
PublicationA proper junction of the prosthesis and the abdominal wall is important in successful hernia repair. The number of tacks should be balanced to assure appropriate mesh fixation and not to induce post-operative pain. Numerical simulations help to find this balance. The study is aimed at creating a proper numerical model of a knitted surgical mesh subjected to boundary conditions and load occurring in the abdominal cavity. Continuous,...
-
Nonlinear material identification of heterogeneous isogeometric Kirchhoff–Love shells
PublicationThis work presents a Finite Element Model Updating inverse methodology for reconstructing heterogeneous materialdistributions based on an efficient isogeometric shell formulation. It uses nonlinear hyperelastic material models suitable fordescribing incompressible material behavior as well as initially curved shells. The material distribution is discretized by bilinearelements such that the nodal values...
Year 2020
-
Constitutive Modelling of Knitted Abdominal Implants in Numerical Simulations of Repaired Hernia Mechanics
PublicationThe paper presents a numerical approach to describe mechanical behavior of anisotropic textile material, which is a selected abdominal prosthesis. Two constitutive nonlinear concepts are compared. In the first one the material is considered composed from two families of threads (dense net model) and in the second one the material is homogeneous but anisotropic (as proposed by Gassel, Ogden, Holzapfel). Parameters of both models...
-
In vivo performance of intraperitoneal onlay mesh after ventral hernia repair
PublicationBackground: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures...
-
Material Identification of the Human Abdominal Wall Based On the Isogeometric Shell Model
PublicationThe human abdominal wall is an object of interest to the research community in the context of ventral hernia repair. Computer models require a priori knowledge of constitutive parameters in order to establish its mechanical response. In this work, the Finite Element Model Updating (FEMU) method is used to identify an heterogeneous shear modulus distribution for a human abdominal wall model, which is based on nonlinear isogeometric...
-
Modelling of Abdominal Wall Under Uncertainty of Material Properties
PublicationThe paper concerns abdominal wall modelling. The accurate prediction and simulation of abdominal wall mechanics are important in the context of optimization of ventral hernia repair. The shell Finite Element model is considered, as the one which can be used in patient-specific approach due to relatively easy geometry generation. However, there are uncertainties in this issue, e.g. related to mechanical properties since the properties...
Year 2019
-
Stiffness change of abdominal prosthesis Optomesh™ under cyclic loading
PublicationAbdominal prostheses are used in humans for abdominal wall strengthening or reconstruction. From the mechanical point of view they are membranes, so their basic mechanical property is tensile stiffness. This property is experimentally identified for a selected implant, OptomeshTM. The obtained results are described herein. Uni-axial simple and cyclic tension tests are a basis for the analysis. Both kinds of tests allowed to distinguish...
Year 2018
-
Towards Understanding of Mechanics of Hernia Managed by Synthetic Mesh in Laparoscopic Operation: A Single Case Study
PublicationIn this paper a research towards understanding of mechanics of ventral hernia operated with the use of Physiomesh Open image in new window implant and SecureStrap Open image in new window staples is described. Experimental and numerical studies are conducted for that purpose. Experimental works cover uni-axial tension tests of the implant samples and of the implant-staples-tissue system. Also experiments on implant-staples-tissue...