Computed tomography indicators of cerebral microperfusion improve long term after carotid stenting in symptomatic patients - Publication - Bridge of Knowledge

Search

Computed tomography indicators of cerebral microperfusion improve long term after carotid stenting in symptomatic patients

Abstract

OBJECTIVES: We tested the hypothesis that computed tomography (CT) perfusion markers of cerebral microcirculation would improve 36 months after internal carotid artery stenting for symptomatic carotid stenosis while results obtained 6-8 weeks after the stenting procedure would yield a predictive value. METHODS: We recruited consecutive eligible patients with >70% symptomatic carotid stenosis with a complete circle of Willis and normal vertebral arteries to the observational cohort study. We detected changes in the cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), time to peak (TTP) and permeability surface area-product (PS) before and after carotid stenting. We have also compared the absolute differences in the ipsilateral and contralateral CT perfusion markers before and after stenting. The search for regression models of "36 months after stenting" results was based on a stepwise analysis with bidirectional elimination method. RESULTS: A total of 34 patients completed the 36 months follow-up (15 females, mean age of 69.68±S.D. 7.61 years). At 36 months after stenting, the absolute values for CT perfusion markers had improved: CBF (ipsilateral: +7.76%, contralateral: +0.95%); CBV (ipsilateral: +5.13%, contralateral: +3.00%); MTT (ipsilateral: -12.90%; contralateral: -5.63%); TTP (ipsilateral: -2.10%, contralateral: -4.73%) and PS (ipsilateral: -35.21%, contralateral: -35.45%). MTT assessed 6-8 weeks after stenting predicted the MTT value 36 months after stenting (ipsilateral: R2=0.867, contralateral R2=0.688). CONCLUSIONS: We have demonstrated improvements in CT perfusion markers of cerebral microcirculation health that persist for at least 3 years after carotid artery stenting in symptomatic patients. MTT assessed 6-8 weeks after stenting yields a predictive value.

Citations

  • 0

    CrossRef

  • 0

    Web of Science

  • 4

    Scopus

Authors (10)

Cite as

Full text

download paper
downloaded 37 times
Publication version
Accepted or Published Version
DOI:
Digital Object Identifier (open in new tab) 10.18388/abp.2018_2793
License
Creative Commons: CC-BY-SA open in new tab

Keywords

Details

Category:
Articles
Type:
artykuły w czasopismach
Published in:
Acta Biochimica Polonica no. 66, pages 229 - 236,
ISSN: 0001-527X
Language:
English
Publication year:
2020
Bibliographic description:
Winklewski P. J., Kaszubowski M., Halena G., Sabisz A., Chojnicki K., Dzierzanowski J., Piskunowicz M., Kurhaluk N., Szurowska E., Szarmach A.: Computed tomography indicators of cerebral microperfusion improve long term after carotid stenting in symptomatic patients// Acta Biochimica Polonica -Vol. 66,iss. 2 (2020), s.229-236
DOI:
Digital Object Identifier (open in new tab) 10.18388/abp.2018_2793
Verified by:
Gdańsk University of Technology

seen 125 times