Abstract
This paper presents tests concerning the rate of corrosion in non-alloy steel (type S235JR) in an aqueous environment, with an additive of sodium chloride by means of polarization resistance measurements and harmonic analysis. The tests have been carried out for steel samples exposed to the testing environment for six weeks, in order to obtain a constant rate of corrosion in the function of time. The measurements have aimed at verifying the use of harmonic analysis in automatic corrosion monitoring systems. For this purpose, a typical three-electrode sensor, which is applied to measurements taken by means of automatic corrosion monitoring systems, has been used. In conclusion, the tests have revealed that harmonic analysis can be a measurement method to be applied in the design of corrosion monitoring systems.
Authors (3)
Cite as
Full text
full text is not available in portal
Keywords
Details
- Category:
- Articles
- Type:
- artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
- Published in:
-
Ochrona przed Korozją
pages 104 - 106,
ISSN: 0473-7733 - Language:
- English
- Publication year:
- 2013
- Bibliographic description:
- Orlikowski J., Łubiński S., Żuchowski P.: Corrosion monitoring by harmonic analysis in aqueous environments// Ochrona przed Korozją. -., nr. 3 (2013), s.104-106
- Verified by:
- Gdańsk University of Technology
seen 136 times