Earthquake-Induced Pounding of Medium-to-High-Rise Base-Isolated Buildings - Publication - Bridge of Knowledge

Search

Earthquake-Induced Pounding of Medium-to-High-Rise Base-Isolated Buildings

Abstract

During earthquakes, out-of-phase vibrations in adjacent buildings with limited distance may cause pounding between them. In recent years, the use of seismic isolation has expanded considerably as an effective approach to reduce seismic damage. However, the isolated building experiences large displacements during earthquakes, and there is a possibility of collisions with adjacent structures. The research on earthquake-induced pounding of base-isolated buildings has been mainly focused on interactions between low structures. In this paper, the influence of structural pounding on the response of medium-to-high-rise base-isolated buildings is investigated under different ground motions. The analysis has been focused on collisions between two insufficiently separated five-story and eight-story base-isolated and fixed base buildings aligned in three different configurations. The results of the study indicate that structural pounding may significantly increase the response of medium-to-high-rise base-isolated buildings during earthquakes. Moreover, substantial dependence of the structural behavior on the gap size between structures has been observed. The general trend shows the reduction in the pounding-involved response with the increase in the gap size value. The results indicate that the increase in the response of the base-isolated building is larger when the height of the structure is bigger. They also show that larger amplifications of peak accelerations of the upper stories can be expected due to collisions. On the other hand, the amplifications of the story shears have not shown any specific trend for different stories of the analyzed base-isolated building.

Citations

  • 2

    CrossRef

  • 0

    Web of Science

  • 2

    Scopus

Cite as

Full text

download paper
downloaded 50 times
Publication version
Accepted or Published Version
License
Creative Commons: CC-BY open in new tab

Keywords

Details

Category:
Articles
Type:
artykuły w czasopismach
Published in:
Applied Sciences-Basel no. 9, pages 1 - 16,
ISSN: 2076-3417
Language:
English
Publication year:
2019
Bibliographic description:
Naderpour H., Danaeifard P., Burkacki D., Jankowski R.: Earthquake-Induced Pounding of Medium-to-High-Rise Base-Isolated Buildings// Applied Sciences-Basel -Vol. 9,iss. 21 (2019), s.1-16
DOI:
Digital Object Identifier (open in new tab) 10.3390/app9214681
Bibliography: test
  1. Anagnostopoulos, S.A. Pounding of buildings in series during earthquakes. Earthq. Eng. Struct. Dyn. 1988, 16, 443-456. [CrossRef] open in new tab
  2. Favvata, M.J.; Karayannis, C.G.; Liolios, A.A. Influence of exterior joint effect on the inter-story pounding interaction of structures. J. Struct. Eng. Mech. 2009, 33, 113-136. [CrossRef] open in new tab
  3. Naderpour, H.; Khatami, S.M. A new model for calculating the impact force and the energy dissipation based on CR-factor and impact velocity. Sci. Iran. 2015, 22, 59-68. open in new tab
  4. Sołtysik, B.; Jankowski, R. Non-linear strain rate analysis of earthquake-induced pounding between steel buildings. Int. J. Earth Sci. Eng. 2013, 6, 429-433. open in new tab
  5. Elwardany, H.; Seleemah, A.; Jankowski, R. Seismic pounding behavior of multi-story buildings in series considering the effect of infill panels. Eng. Struct. 2017, 144, 139-150. [CrossRef] open in new tab
  6. Khatami, S.M.; Naderpour, H.; Barros, R.C.; Jakubczyk-Gałczyńska, A.; Jankowski, R. Effective formula for impact damping ratio for simulation of earthquake-induced structural pounding. Geosciences 2019, 9, 347. [CrossRef] open in new tab
  7. Rosenblueth, E.; Meli, R. The 1985 earthquake: Causes and effects in Mexico City. Concr. Int. 1986, 8, 23-34.
  8. Kasai, K.; Maison, B.F. Building pounding damage during the 1989 Loma Prieta earthquake. Eng. Struct. 1997, 19, 195-207. [CrossRef] open in new tab
  9. Eurocode 8: Design Provisions for Earthquake Resistance of Structures; European Committee for Standardization: Brussels, Belgium, 1998. open in new tab
  10. Jankowski, R.; Mahmoud, S. Linking of adjacent three-storey buildings for mitigation of structural pounding during earthquakes. Bull. Earthq. Eng. 2016, 14, 3075-3097. [CrossRef] open in new tab
  11. Naeim, F.; Kelly, J.M. Design of Seismic Isolated Structures: From Theory to Practice; open in new tab
  12. Falborski, T.; Jankowski, R. Experimental study on effectiveness of a prototype seismic isolation system made of polymeric bearings. Appl. Sci. 2017, 7, 808. [CrossRef] open in new tab
  13. Falborski, T.; Jankowski, R.; Kwiecień, A. Experimental study on polymer mass used to repair damaged structures. Key Eng. Mater. 2012, 488, 347-350. [CrossRef] open in new tab
  14. Naderpour, H.; Naji, N.; Burkacki, D.; Jankowski, R. Seismic response of high-rise buildings equipped with base isolation and non-traditional tuned mass dampers. Appl. Sci. 2019, 9, 1201. [CrossRef] open in new tab
  15. Kelly, J.M. Earthquake-Resistant Design with Rubber; Springer: London, UK, 1993. open in new tab
  16. Skinner, R.I.; Kelly, J.M.; Heine, A.J. Hysteretic dampers for earthquake-resistant structures. Earthq. Eng. Struct. Dyn. 1975, 3, 287-296. [CrossRef] open in new tab
  17. Kumar, M.; Whittaker, A.S.; Constantinou, M.C. An advanced numerical model of elastomeric seismic isolation bearings. Earthq. Eng. Struct. Dyn. 2014, 43, 1955-1974. [CrossRef] open in new tab
  18. Kumar, M.; Whittaker, A.S.; Constantinou, M.C. Characterizing friction in sliding isolation bearings. Earthq. Eng. Struct. Dyn. 2015, 44, 1409-1425. [CrossRef] open in new tab
  19. Nagarajaiah, S.; Sun, X. Seismic performance of base-isolated buildings in the 1994 Northridge earthquake. In Proceedings of the 11th World Conference on Earthquake Engineering, Acapulco, Mexico, 23-28 June 1996. paper no. 598. open in new tab
  20. Das, S.; Gur, S.; Mishra, S.K.; Chakraborty, S. Optimal performance of base isolated building considering limitation on excessive isolator displacement. Struct. Infrastruct. Eng. 2015, 11, 904-917. [CrossRef] open in new tab
  21. Fallah, N.; Zamiri, G. Multi-objective optimal design of sliding base isolation using genetic algorithm. Sci. Iran. 2013, 20, 87-96. [CrossRef] open in new tab
  22. Jain, S.K.; Thakkar, S.K. Application of base isolation for flexible buildings. In Proceedings of the 13th World Conference on Earthquake Engineering, Vancouver, BC, Canada, 1-6 August 2004. paper no. 1924. open in new tab
  23. Zelleke, D.H.; Elias, S.; Matsagar, V.A.; Jain, A.K. Supplemental dampers in base-isolated buildings to mitigate large isolator displacement under earthquake excitations. Bull. N. Z. Soc. Earthq. Eng. 2015, 48, 100-117. [CrossRef] open in new tab
  24. Fu, W.; Zhang, C.; Sun, L.; Askari, M.; Samali, B.; Chung, K.L.; Sharafi, P. Experimental investigation of a base isolation system incorporating MR dampers with the high-order single step control algorithm. Appl. Sci. 2017, 7, 344. [CrossRef] open in new tab
  25. AlMusbahi, S.; Güngör, A. A composite building isolation system for earthquake protection. Eng. Sci. Technol. Int. J. 2019, 22, 399-404. [CrossRef] open in new tab
  26. Nagarajaiah, S.; Sun, X. Base-isolated FCC building: Impact response in Northridge earthquake. J. Struct. Eng. 2001, 127, 1063-1075. [CrossRef] open in new tab
  27. Tsai, H.C. Dynamic analysis of base-isolated shear beams bumping against stops. Earthq. Eng. Struct. Dyn. 1997, 26, 515-528. [CrossRef] open in new tab
  28. Malhotra, P.K. Dynamics of seismic impacts in base-isolated buildings. Earthq. Eng. Struct. Dyn. 1997, 26, 797-813. [CrossRef] open in new tab
  29. Dimova, S.L. Numerical problems in modelling of collision in sliding systems subjected to seismic excitations. Adv. Eng. Softw. 2000, 31, 467-471. [CrossRef] open in new tab
  30. Matsagar, V.A.; Jangid, R.S. Seismic response of base-isolated structures during impact with adjacent structures. Eng. Struct. 2003, 25, 1311-1323. [CrossRef] open in new tab
  31. Komodromos, P.; Polycarpou, P.C.; Papaloizou, L.; Phocas, M.C. Response of seismically isolated buildings considering poundings. Earthq. Eng. Struct. Dyn. 2007, 36, 1605-1622. [CrossRef] open in new tab
  32. Komodromos, P. Simulation of the earthquake-induced pounding of seismically isolated buildings. Comput. Struct. 2008, 86, 618-626. [CrossRef] open in new tab
  33. Agarwal, V.K.; Niedzwecki, J.M.; van de Lindt, J.W. Earthquake induced pounding in friction varying base isolated buildings. Eng. Struct. 2007, 29, 2825-2832. [CrossRef] open in new tab
  34. Mahmoud, S.; Jankowski, R. Pounding-involved response of isolated and non-isolated buildings under earthquake excitation. Earthq. Struct. 2010, 1, 231-252. [CrossRef] open in new tab
  35. Polycarpou, P.C.; Komodromos, P. Earthquake-induced poundings of a seismically isolated building with adjacent structures. Eng. Struct. 2010, 32, 1937-1951. [CrossRef] open in new tab
  36. Bedon, C.; Morassi, A. Dynamic testing and parameter identification of a base-isolated bridge. Eng. Struct. 2014, 60, 85-99. [CrossRef] open in new tab
  37. Vaseghi Amiri, J.; Jalali, S.G. Study of different contact elements in poundings of steel buildings. J. Model. Eng. 2011, 9, 1-20. open in new tab
  38. Jankowski, R. Pounding between superstructure segments in multi-supported elevated bridge with three-span continuous deck under 3D non-uniform earthquake excitation. J. Earthq. Tsunami 2015, 9, 1550012. [CrossRef] open in new tab
  39. Chopra, A.K. Dynamics of Structures: Theory and Applications to Earthquake Engineering;
  40. Prentice-Hall: Englewood Cliffs, NJ, USA, 1995. © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). open in new tab
Verified by:
Gdańsk University of Technology

seen 123 times

Recommended for you

Meta Tags