  • 3D polypyrrole structures as a sensing material for glucose detection
    Publication

    In this work, 3D polypyrrole (PPy) structures as material for glucose detection is proposed. Polypyrrole was electrochemically polymerized on platinum screen-printed electrode from an aqueous solution of lithium perchlorate and pyrrole. The growth mechanism of such PPy structures was studied by ex-situ scanning electron microscopy. Preliminary studies show that studied here PPy film is a good candidate as a sensing material for...

  • A new diagnostic IR-thermal imaging method for evaluation of cardiosurgery procedures

    Two methods for monitoring the state of the myocardium during cardiosurgical interventions based on thermal IR imaging are presented below. These methods, called static thermography and active dynamic thermography (ADT), use information about the distribution of temperature on the surface, and an external excitation source to induce thermal transient processes in a tested object. Recording the time series of thermograms allows...

    Full text to download in external service

  • A new diagnostic method for evaluation of cardiosurgery wound healing
    Publication

    One of important and still unsolved problems in medicine is the question of objective and quantitative evaluation of post-surgery wound healing. The aim of this research is to analyse possibility and value of using the newly elaborated infrared imaging procedure – Active Dynamic Thermography (ADT) – for quantitative description of wound healing processes in cardiosurgery. Both, classical thermal figures of merit as well as ADT...

    Full text to download in external service

  • A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
    Publication

    - Year 2016

    In this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...

    Full text to download in external service

  • Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
    Publication

    In this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...

    Full text to download in external service

  • Active IR-Thermal Imaging in Medicine

    In this paper we summarize results of several research projects devoted to development of new diagnostic methods and procedures based on quantitative infrared thermography in medical applications. First, basics of active dynamic thermography are presented. Described are both, instrumentation and software comprising measurement procedures including collection of series of IR-images after external excitation, data treatment with...

    Full text available to download

Year 2024
Year 2018
Year 2017
  • A body position influence on ECG derived respiration

    An influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...

    Full text to download in external service

  • A navigation device utilizing body communication channel for mobile wearable systems
    Publication

    - Year 2017

    A novel touch sensor utilizing a body communication technology is presented in the paper. The proposed device accepts orders (gestures) only from a person wearing it. Moreover, when comparing it to a similar, however an optical one, it appears as a less power consumable. Preliminary results of its properties examination are presented and discussed. Additionally, the developed sensor allows to measure a human body the electrical...

    Full text available to download

  • A novel sensor for measuring temperature profile during the thermoablation
    Publication

    - Year 2017

    Abstract — A novel approach for monitoring a temperature distribution inside a tissue during thermoablation is presented in the paper. A thermal profile is measured using a set of serially connected thermistors each bypassed by a capacitor. This technique allows a two-wire and simultaneous multi- point measurements using a multi-frequency measurement of electrical impedance. It is...

    Full text available to download

  • A scale with ECG measurements capability for home cardiac monitoring

    Presented device -a scale developed for enabling extra measurements, in addition to body weight and composition, the electrical activity of the heart (electrocardiogram - ECG) and the level of oxygen saturation in the blood SaO2. Electrical activity is recorded in the form of six leads, socalled - limb leads. The device allows measurement of all standard limb leads and without the need for additional procedures. ECG, although the...

    Full text to download in external service

  • Active Dynamic Thermography in Medical Diagnostics
    Publication

    This is an overview of active thermal imaging methods in medical diagnostics using external thermal stimulation. In this chapter, several clinical cases diagnosed using the active dynamic thermography method, ADT, are presented. Features of this technology are discussed and main advantages underlined. Applications in skin burn diagnostics and quantitative evaluation leading to modern classification of burned patients for further...

    Full text to download in external service

  • Active dynamic thermography method for TRAM flap blood perfusion mapping in breast reconstruction
    Publication

    - QIRT Journal - Year 2017

    This paper presents the new method of the transverse rectus abdominis musculocutaneous flap blood perfusion mapping based on the active dynamic thermography. The method is aimed at aiding a surgeon during breast reconstruction procedure. A pair of dTnorm and t90_10 parameters were used as parametric image descriptors of the flap blood perfusion. The method was tested on 38 patients that were subjected to breast reconstruction procedure....

    Full text available to download

  • Acute hypoxia diminishes the relationship between blood pressure and subarachnoid space width oscillations at the human cardiac frequency
    Publication
    • M. Wszędybył-Winklewska
    • J. Wolf
    • E. Świerblewska
    • K. Kunicka
    • A. Gruszecka
    • M. Gruszecki
    • W. Kucharska
    • P. J. Winklewski
    • J. Zabulewicz
    • W. Gumiński... and 5 others

    - PLOS ONE - Year 2017

    Acute hypoxia exerts strong effects on the cardiovascular system. Heart-generated pulsatile cerebrospinal fluid motion is recognised as a key factor ensuring brain homeostasis. We aimed to assess changes in heart-generated coupling between blood pressure and subarachnoid space width oscillations during hypoxic exposure.

    Full text available to download

Year 2014
Year 2015
Year 2010
Year 2021
Year 2013
  • A multisensor detector of a sleep apnea for using at home

    Diagnosis of obstructive sleep apnea usually involves polysomnographic analysis, which unfortunately requires overnight stay in a specialized clinic and is very uncomfortable for a patient. This paper describes the method and apparatus for recording a set of signals to detect sleep apnea. The device records the following signals simultaneously: three-channel ECG, respiratory functions, signals from the accelerometer, and snoring...

    Full text to download in external service

  • ADT in mammography
    Publication

    We discuss limitations of the known methods of IR imaging in diagnostics of breast cancer. In conclusion we show that for practical reasons one requires new approaches because the known methods based on simple observation of external temperature distribution are not fully effective. Even advanced pattern recognition could not help too much for static images. We ask the question: may active dynamic thermography, known in nondestructive...

Year 2006
  • A new OSS design based on parameter sensitivity tochanges in measurements
    Publication

    W wyniku istniejących silnych ograniczeń praktycznych i etycznych nałożonych na eksperymenty medyczne, procedura estymacji parametrów w diagnozie i terapii jest często zagadnieniem skomplikowanym. Jeśli dane pomiarowe pobierane są w postaci próbek krwi, liczba tych próbek, a także czas obserwacji powinny być zminimalizowane. Optymalizacja eksperymentu polega na optymalizacji odpowiedniego sformułowanego kryterium będącego funkcją...

Year 2019
Year 2007
Year 2023
  • A review of methods of blood supply to organs of the gastrointestinal tract. State of art
    Publication

    - EJSO-EUR J SURG ONC - Year 2023

    The correct assessment of blood supply is essential to eliminate possible postoperative complications. Re-anastomosis of the gastrointestinal tract after its resection must be preceded by the analysis of blood supply to the anastomosed fragments. It is important that the blood supply assessment procedure is reliable but also non-absorbing and, if possible, short. It should also be possible to repeat the procedure due to the need...

    Full text to download in external service

Year 2002
Year 2012
Year 2020
Year 2011
Year 2009
Year 2008
Year 2022
Year 2003
  • Aktywna termografia dynamiczna w badaniach mammograficznych.
    Publication

    W artykule przedstawiono analizę możliwości i ograniczeń metod termograficznych w diagnostyce nowotworów piersi. Przeanalizowane w artykule modele numeryczne piersi z nowotworem pokazują, iż zastosowanie nowej metody aktywnej termografii dynamicznej z termicznym wymuszeniem zewnętrznym może znacząco poprawić skuteczność wykrywania nowotworów piersi we wczesnym stadium rozwoju. Pokazano również wyniki badania klinicznego pacjentki...