dr inż. Ewa Janicka
Social media
Contact
- ewa.janicka@pg.edu.pl
Publication showcase
-
Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks
Dynamic Electrochemical Impedance Spectroscopy (DEIS) was presented as novel method for diagnostic and monitoring of PEMFC stack and single cells operation. Impedance characteristics were obtained simultaneously with current - voltage characteristics for stack and each individual cell. Impedance measurements were performed in galvanodynamic mode. It allowed to compare performance of each cell and identification of faulty cell operation...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
Starvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
A complete impedance analysis of electrochemical cells used as energy sources
A comprehensive description of impedance ofelectrochemical systems has been presented, along withthe assumptions of the method used. In this method, amultisinusoidal current excitation signal is used. Thechanges of potential of both the electrodes and thepotential difference between these electrodes are allregistered simultaneously as a function of time. Theproposed method offers the possibility of separatelydetermining the instantaneous...
seen 1976 times