prof. dr hab. inż. Jerzy Wtorek
Employment
- Professor at Department of Biomedical Engineering
Research fields
Publications
Filters
total: 149
Catalog Publications
Year 2024
-
A Novel Device and System for Fall Detection Under the Shower
PublicationIn this paper, device construction and preliminary results for shower safety assistance are presented. The device allows monitoring of shower-taking persons without violating privacy and intimacy, while it has the ability to detect a persons entering and leaving the shower and detecting fall conditions. It allows better supervision of elders living independently at their locations.
-
Diagnostics of the Peripheral Artery Disease with use of Glucose Sensor - A Proof of Concept
PublicationIt is estimated that 13 % of population over 50 years old suffer from symptomatic or asymptomatic peripheral artery disease (PAD). Ankle-brachial index (ABI) is viewed as a useful parameter in diagnostics of peripheral arterial disease, however screening tests with usage of this method are not advised. Hypoxia causes increase in lactate values and...
-
Diagnostics of the Peripheral Artery Disease with use of Glucose Sensor - A Proof of Concept
PublicationIt is estimated that 13% of population over 50 years old suffer from symptomatic or asymptomatic peripheral artery disease (PAD). Ankle-brachial index (ABI) is viewed as a useful parameter in diagnostics of peripheral arterial disease, however screening tests with usage of this method are not advised. Hypoxia causes increase in lactate values and decrease in blood glucose. We hypothesize that the deficit in blood supply to the...
-
Flap Monitoring Techniques: A Review
PublicationPostoperative tissue flap vitality monitoring enables early detection of clinical complications, allowing for intervention. Timely re-operation can prevent the need for extensive correction procedures, thus reducing healthcare costs and hospitalisation time. Statistics show that monitoring can increase the success rate of flap survival to 95\% or higher. However, despite the significant progress in monitoring techniques, major...
-
Pulse Transit Time - Fiducial Points Accuracy Determination as Examined by Means of Synthetic Signals
PublicationThere are many approaches to non-invasively deter-mine blood pressure. Among them there are methods based on utilizing pulse transit time measured by means of photoplethys-mography. The variability of the blood pressure drop between two measurement sensors placed along the artery and its dependence on the selected parameters describing the cardiovascular system is presented in the paper. This pressure drop modifies the pressure...
Year 2023
-
A review of methods of blood supply to organs of the gastrointestinal tract. State of art
PublicationThe correct assessment of blood supply is essential to eliminate possible postoperative complications. Re-anastomosis of the gastrointestinal tract after its resection must be preceded by the analysis of blood supply to the anastomosed fragments. It is important that the blood supply assessment procedure is reliable but also non-absorbing and, if possible, short. It should also be possible to repeat the procedure due to the need...
Year 2022
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
QRS Morphology-Based EDR Signal—Factors Determining its Properties
PublicationRespiration-induced signals contain a clinically significant information. It could be obtained utilizing both direct and indirect methods. ECG-Derived Respiration (EDR) method is the latter one. However, in this case, two approaches could be distinguished. First one is based on determining changes in the morphology of QRS complexes while the second one is based on the Respiratory Sinus Arrhythmia (RSA) mechanism. The former approach...
Year 2021
-
Coupling between Blood Pressure and Subarachnoid Space Width Oscillations during Slow Breathing
PublicationThe precise mechanisms connecting the cardiovascular system and the cerebrospinal fluid (CSF) are not well understood in detail. This paper investigates the couplings between the cardiac and respiratory components, as extracted from blood pressure (BP) signals and oscillations of the subarachnoid space width (SAS), collected during slow ventilation and ventilation against inspiration resistance. The experiment was performed on...
-
DETECTION OF BREATHING AND HEART RATE USING AN ECG SIGNAL MEASURED WHILE BATHING IN THE BATHTUB
PublicationNowadays a new area of interest is gaining importance - it is home biomedical examination. Intelligent home can be supported by set of devices for habitants observation. It can be particularly useful for elders or person with some health risks but living alone. One of critical locations within the house is bathroom. One of utilities in the bathroom is a bathtub which is sometimes preferred over shower. There are reports of problems...
-
Influence of preprocessing techniques on pulse pressure velocity determination
PublicationPulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...
Year 2020
-
Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
PublicationA non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...
-
Design aspects of a low-cost prosthetic arm for people with severe movement disabilities
PublicationIn this paper the main aspects of mechanical design behind the low-cost prosthetic arm are presented. The fundamentals of a proper design has been defined to obtain functional 3D printed 5 degree of freedom (DOF) prosthesis. The designed prosthetic arm is a part of the hybrid interface with eye tracking movement control. The main focus was to create affordable but usable prosthesis which corresponds in size and weights to the human...
-
Neural network based algorithm for hand gesture detection in a low-cost microprocessor applications
PublicationIn this paper the simple architecture of neural network for hand gesture classification was presented. The network classifies the previously calculated parameters of EMG signals. The main goal of this project was to develop simple solution that is not computationally complex and can be implemented on microprocessors in low-cost 3D printed prosthetic arms. As the part of conducted research the data set EMG signals corresponding...
-
Optical sensor of a person sitting on a chair and dressed in multi-layered clothes vital signs monitoring
PublicationAn optoelectronic device enhancing a smart chair functionality is presented in the paper. Its essential purpose is a detection of a sitting person presence on the chair by means of detecting the vital signs. Additionally, it could be used for determining of clothes layer parameters useful in adjusting a system of a capacitive electrocardiography.
-
Respiratory signals derived from capacitive electrocardiogram on the smart chair
PublicationCapacitive electrocardiogram (CECG) tends to deliver basic cardiac signals without need to use traditional glued electrodes. In the paper analysis of possibility if the ECG derived respiratory waveforms out of the CECG.
Year 2019
-
A Wearable System Developed to Monitor People Suffering from Vasovagal Syncope
PublicationA wearable system for monitoring non-invasively signals invaluable when examining person suffering from vasovagal syncope is presented in the paper. Following signals are continuously recorded: electrocardiogram, photopletysmogram, impedance cardiogram and electrodermal resistance.
-
Can we rely on the pulse transit time - pressure relationship - models comparison
PublicationAn unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...
-
Coupling of Blood Pressure and Subarachnoid Space Oscillations at Cardiac Frequency Evoked by Handgrip and Cold Tests: A Bispectral Analysis
PublicationThe aim of the study was to assess blood pressure–subarachnoid space (BP–SAS) width coupling properties using time–frequency bispectral analysis based on wavelet transforms during handgrip and cold tests. The experiments were performed on a group of 16 healthy subjects (F/M; 7/9) of the mean age 27.2 ± 6.8 years and body mass index of 23.8 ± 4.1 kg/m². The sequence of challenges was first handgrip and then cold test. The handgrip...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
Estimation of electrode contact in capacitive ECG measurement
PublicationIn the paper a method of electrode’s contact estimation in capacitive electrocardiogram (CECG) is presented. Proposed solution allows estimation of contact quality for each individual electrode. This enables construction of multi-electrode CECG systems, where electrode pairs can be selected on the basis of the individual electrode contact quality.
-
Impact of slow breathing on the blood pressure and subarachnoid space width oscillations in humans
PublicationThe aim of the study was to assess cardiac and respiratory blood pressure (BP) and subarachnoid space (SAS) width oscillations during the resting state for slow and fast breathing and breathing against inspiratory resistance. Experiments were performed on a group of 20 healthy volunteers (8 males and 12 females; age 25.3 ± 7.9 years; BMI = 22.1 ± 3.2 kg/m2). BP and heart rate (HR) were measured using continuous finger-pulse photoplethysmography....
-
Optimal ECG lead for deriving respiratory signal
PublicationEDR is an interesting measuring technique that allows an indirect assessment of respiratory activity. This is an alternative solution to direct methods that are based on the measurement of air flow, which require a specialized sensor or even a system. However, due to inter-personal anatomical differences, the optimal ECG lead (placement of the electrodes) ensuring the best EDR signal quality is not fixed. An influence of ECG lead...
-
Respiratory signal of bathing person - preliminary study
PublicationThe scope of this paper is analysis of applicability of modern biomedical acquisition system installed in bathtub towards reception of respiratory signals of bathing person. An analysis of the possibility of such measurement is shown as well as preliminary results.
-
Systemy automatycznej detekcji bezdechu sennego
PublicationZgodnie z przyjętą klasyfikacją międzynarodową identyfikowanych jest ponad 60 różnych zaburzeń snu [58] z podziałem na 7 kategorii. Bezdech senny, zarówno centralny jak i obturacyjny zaliczany jest do kategorii drugiej. Systemy pomiarowe wykorzystywane w monitorowaniu i diagnozie snu, w tym wykorzystywane do detekcji bezdechu sennego, można sklasyfikować ze względu na wiele kryteriów, np. ze względu na to czy badania wykonywane...
-
Using Eye-tracking to get information on the skills acquisition by the radiology residents
PublicationThis paper describes the possibility of monitoring the progress of knowledge and skills acquisition by the students of radiology. It is achieved by an analysis of a visual attention distribution patterns during image-based tasks solving. The concept is to use the eye-tracking data to recognize the way how the radiographic images are read by recognized experts, radiography residents involved in the training program, and untrained...
-
ZINTEGROWANY SYSTEM DOMOWEGO MONITORINGU PARAMETRÓW MEDYCZNYCH OSÓB STARSZYCH I CHORYCH
PublicationProponowane rozwiązania mają na celu wspomaganie osób starszych i chorych, tak by mogły jak najdłużej mieszkać i żyć samodzielnie ze zwiększonym poczuciem bezpieczeństwa, iż są nadzorowane i w razie nagłego zagrożenia życia nie pozostaną bez pomocy. System jednocześnie nie narusza poczucia zachowania prywatności i intymności, gdyż nie są używane do monitoringu kamery wizyjne czy też stały nasłuch audio. Dodatkowo gromadzone informacje...
Year 2018
-
A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation
PublicationThe paper presents a preliminary meta-analysis of the sample correlation between pulse arrival time (PAT) and blood pressure (BP). The aim of the study was to verify sample correlation coefficient between PAT and BP using an affine model BP = a · P AT + b for systolic and diastolic blood pressure. The databases included in the search were the IEEE Xplore Digital Library, Springer Link and Google Scholar. Only papers from 2005 to...
-
Electrical Propterties of Solution Mixtures for Bath Supervision in Ambient Assisted Living
PublicationImpedance properties of bath solution are compared. Any ingredient such as soap, shampoo or bathing salt changes bath-solution’s electrical properties eg. impedance. We have measured and analysed influence of typical bathing ingredients on electrical properties of the solution. We investigate impedance changes over frequency range from 100Hz tu 100kHz as it is most applicable for person detection. Electrical properties of bath...
-
Smart Weighing Scale with Feet-Sampled ECG
PublicationIn a smart home, health and well-being monitoring systems could be embedded in everyday devices providing a pervasive care. A home bathroom scale is an example of such a device, typically used to measure body weight and very often its composition (e.g. body water/fat percentage). In this paper, we analyzed a potential use of the bathroom scale to measure electrocardiogram (ECG) from electrodes located on the scale's tile. In particular...
-
The passive operating mode of the linear optical gesture sensor
PublicationThe study evaluates the influence of natural light conditions on the effectiveness of the linear optical gesture sensor, working in the presence of ambient light only (passive mode). The orientations of the device in reference to the light source were modified in order to verify the sensitivity of the sensor. A criterion for the differentiation between two states - "possible gesture" and "no gesture" - was proposed. Additionally,...
-
Using Wearable Electronics to Estimate Usefulness of Heart Rate Variability for Bathing Person Identif Cation
PublicationIn this paper the possibility of person identification based on biosignal is investigated. The work focus on the analysis of the changes in intervals between successive R-waves of electrocardiogram (ECG) recorded by wearable electronics in form of a necklaces. The main idea behind this project is to find efficient tool which may prevent sudden consciousness loss episodes or even sudden death episodes related to rapid temperature...
Year 2017
-
A body position influence on ECG derived respiration
PublicationAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
A navigation device utilizing body communication channel for mobile wearable systems
PublicationA novel touch sensor utilizing a body communication technology is presented in the paper. The proposed device accepts orders (gestures) only from a person wearing it. Moreover, when comparing it to a similar, however an optical one, it appears as a less power consumable. Preliminary results of its properties examination are presented and discussed. Additionally, the developed sensor allows to measure a human body the electrical...
-
A novel sensor for measuring temperature profile during the thermoablation
PublicationAbstract — A novel approach for monitoring a temperature distribution inside a tissue during thermoablation is presented in the paper. A thermal profile is measured using a set of serially connected thermistors each bypassed by a capacitor. This technique allows a two-wire and simultaneous multi- point measurements using a multi-frequency measurement of electrical impedance. It is...
-
A scale with ECG measurements capability for home cardiac monitoring
PublicationPresented device -a scale developed for enabling extra measurements, in addition to body weight and composition, the electrical activity of the heart (electrocardiogram - ECG) and the level of oxygen saturation in the blood SaO2. Electrical activity is recorded in the form of six leads, socalled - limb leads. The device allows measurement of all standard limb leads and without the need for additional procedures. ECG, although the...
-
Analysis of Properties of an Active Linear Gesture Sensor
PublicationBasic gesture sensors can play a significant role as input units in mobile smart devices. However, they have to handle a wide variety of gestures while preserving the advantages of basic sensors. In this paper a user-determined approach to the design of a sparse optical gesture sensor is proposed. The statistical research on a study group of individuals includes the measurement of user-related parameters like the speed of a performed...
-
Capacitively coupled ECG measurements - a CMRR circuit improvement
PublicationA typical galvanic-connected electrocardiogram (ECG) measurement system utilizes two signal’s electrodes and a third one in driven-right-leg (DRL) circuit for improving a common-mode rejection ratio(CMRR) of the acquisition system. In capacitive-coupled ECG similar techniques are used, however it is expected, that the utilized DRL subsystem is formed using a capacitive coupling approach, too. An improvement of the acquisition system...
-
Extending touch-less interaction with smart glasses by implementing EMG module
PublicationIn this paper we propose to use temporal muscle contraction to perform certain actions. Method: The set of muscle contractions corresponding to one of three actions including “single-click”, “double-click” “click-n-hold” and “non-action” were recorded. After recording certain amount of signals, the set of five parameters was calculated. These parameters served as an input matrix for the neural network. Two-layer feedforward neural...
-
Open smart glasses development platform for AAL applications
PublicationThis paper describes an open platform for multi sensory electronic glasses that supports new and enhanced methods for intelligent interaction with patients, with smart objects, or to be used as new data input modalities like proximity sensor or smart textile interfaces. All the activities have been developed, investigated and evaluated within EU CHIST-ERA eGlasses project...
-
Pose classification in the gesture recognition using the linear optical sensor
PublicationGesture sensors for mobile devices, which have a capability of distinguishing hand poses, require efficient and accurate classifiers in order to recognize gestures based on the sequences of primitives. Two methods of poses recognition for the optical linear sensor were proposed and validated. The Gaussian distribution fitting and Artificial Neural Network based methods represent two kinds of classification approaches. Three types...
-
The motion influence on respiration rate estimation from low-resolution thermal sequences during attention focusing tasks
PublicationGlobal aging has led to a growing expectancy for creating home-based platforms for indoor monitoring of elderly people. A motivation is to provide a non-intrusive technique, which does not require special activities of a patient but allows for remote monitoring of elderly people while assisting them with their daily activities. The goal of our study was to evaluate motion performed by a person focused on a specific task and check...
-
The role of EMG module in hybrid interface of prosthetic arm
PublicationNearly 10% of all upper limb amputations concern the whole arm. It affects the mobility and reduces the productivity of such a person. These two factors can be restored by using prosthetics. However, the complexity of human arm makes restoring its basic functions quite difficult. When the osseointegration and/or targeted muscle reinnervation (TMR) are not possible, different modalities can be used to control the prosthesis. In...
-
Using wearable device for biomedical signal acquisition and processing
PublicationIn this paper we present the research conducted on synchronous measurements of biosignals. The experiment was conducted to evaluate the possibility of estimating vital signs based on eye tracking. Method: The eGlasses platform was used for acquisition of ECG, respiration rate, eye and pupil movement and blood pressure. Data were acquired in three 5 min. intervals during which a subject was performing certain tasks. The signals...
Year 2016
-
A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
PublicationIn this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...
-
Multichannel Human Body Communication
PublicationHuman Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog...
-
Performance Analysis of Interaction between Smart Glasses and Smart Objects Using Image-Based Object Identification
PublicationWe propose the use of smart glasses to collaborate with smart objects in the Internet of Things environment. Particularly we are focusing on new interaction methods and the analysis of acceptable reaction times in the process of object recognition using smart glasses. We evaluated the proposed method using user studies and experiments with three different smart glasses: Google Glass, Epson Moverio, and the developed eGlasses platform....
-
Semi complex navigation with an active optical gesture sensor
PublicationThis paper presents the methods of diversified touchless interactions between a user and a mobile platform utilizing the optical gesture sensor. The sensor uses 8 photodiodes to measure the reflected light in the active mode (using embedded LEDs) or it measures shadows caused by fingers in the passive mode. Several algorithms were implemented: automatic mode switching, adaptive illumination level compensation, resolution improvements...
-
The evaluation of eGlasses eye tracking module as an extension for Scratch
PublicationIn this paper we present the possibility of using eGlasses eye tracking module as an extension for Scratch programming tool which is a visual programming language supporting computer skills learning. The main concept behind this project is to setup the interface for rapid interaction design. Eye tracking is a powerful tool for hands free communication but for that requires a dedicated software. This software is rarely tailored...
Year 2015
-
A Special Section on Intelligent User Interfaces in Healthcare (IUIH)
PublicationA concept of interface has evolved from the first appearance in the form of a command line interface to the established use of direct manipulation or WIMP (windows, icons, menus and pointing) interfaces in nearly all applications. Intelligent user interfaces (IUI) form a subfield of Human-Computer Interaction research. Optimal human-computer interactions are defined as ones where users are able to perform complex tasks more quickly...
seen 5023 times