Michał Narożny
Employment
Publications
Filters
total: 12
Catalog Publications
Year 2018
-
Application of Electrochemical Impedance Spectroscopy to evaluate cathodically protected coated steel in seawater
PublicationTwo types of organic coated carbon steel (S235JR2 grade) electrodes were exposed to artificial seawater environment. One prepared type was defect free while the other one had an intentionally introduced φ0,5 cm coating defect. Both kinds of samples were polarized during the exposure to four potentials corresponding to four different cathodic protection levels. Evolution of their EIS spectra is presented in this paper. Results obtained...
Year 2017
-
Time evolution of Electrochemical Impedance spectra of cathodically protected steel in artificial seawater
PublicationUsability of Electrochemical Impedance Spectroscopy data for better cathodic protection control was investigated. Carbon steel – S235JR2 grade specimen were exposed in artificial seawater environment. Samples were polarized and their potentials corresponded to four different cathodic protection degrees. Time evolution of Electrochemical Impedance spectra was investigated. Goodness of fit function (X2) was analysed in terms of proper...
Year 2016
-
Wykorzystanie technik zmiennoprądowych w analizie polaryzacji katodowej stali
PublicationRozprawę doktorską pod tytułem „Wykorzystanie technik zmiennoprądowych w analizie polaryzacji katodowej stali” podzielono na trzy zasadnicze części, które nawiązują do zróżnicowanego charakteru tematyki korozyjnej. W pierwszym rozdziale pracy podjęto problematykę kryteriów ochrony katodowej stosowanych w dokumentach technicznych. Przedstawiono podstawy teoretyczne ochrony katodowej oraz poddano analizie obecnie stosowane normy....
Year 2015
-
Method of sacrificial anode dual transistor-driving in stray current field
PublicationIn order to control a magnesium anode in a stray current interference field, a dual transistor driving system has been proposed. It consisted of a combination of PNP and NPN transistors. Dual transistor driven system and direct anode to cathode connection were electrochemically tested in 3% NaCl solution. The dual transistor driven system increased the anode efficiency and reduced hydrogen evolution and the risk of embrittlement....
-
Ocena techniczna określająca stan i efektywność zabezpieczenia antykorozyjnego w postaci ochrony katodowej obiektów PPPP „NAFTOPORT” sp. z o.o.
PublicationDokonano oceny skuteczności ochrony katodowej realizowanej za pomocą anod galwanicznych w Bazie Przeładunku Paliw Płynnych w Porcie Północnym w Gdańsku na następujących obiektach: zapory przeciwrozlewowe, stanowiska przeładunkowe, estakady rurociągów, pomosty, dalby cumownicze i odbojowe, monitory p.poż. Oceny dokonano na podstawie wykonanych pomiarów potencjału polaryzowanych katodowo obiektów.
-
Protection of bridges against stray current corrosion
PublicationA case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system...
Year 2014
-
Ekspertyza oddziaływania napowietrznych linii wysokiego napięcia
PublicationWykonano obliczeń oddziaływania linii 400kV i 110kV na gazociągi DN500, DN400 i DN100 w miejscach ich kolizji oraz wyznaczono gęstości upływających prądów przez jednostkowy defekt o powierzchni 1cm^2.
-
Influence of water salinity on corrosion risk - the case of the southern Baltic Sea coast.
PublicationWater corrosivity in Gdansk Bay, Poland, the southern part of the Baltic Sea, was investigated. The analysed region is heavily industrialized, and the coastline is very diverse. Twenty-seven test points along the coastline were selected. Water parameters such as salinity, total dissolved solids content, resistivity, conductivity, oxygenation, pH and corrosion rate were determined. The results of the investigation are presented....
-
Method of sacrificial anode transistor-driving in cathodic protection system
PublicationA magnesium anode driving system has been proposed. A PNP driving transistor has been used. Electrochemical testing in 3%NaCl, results and comparison of the driving system and classic direct anode to cathode connection are presented. The driving system reduced the protection current and stabilized the working conditions of the anode. Higher anode efficiency was achieved. Overprotection and hydrogen embrittlement threats were prevented...
-
Pomiary skuteczności ochrony katodowej stanowiska przeładunkowego T1 w Bazie Przeładunku Paliw Płynnych w Porcie Północnym w Gdańsku.
PublicationWykonano pomiary potencjału oraz określono skuteczność działania ochrony katodowej stalowych konstrukcji podwodnych na nowo wybudowanym stanowisku przeładunkowym T1 przy falochronie wewnętrznym północnym w Bazie Przeładunku Paliw Płynnych w Porcie Północnym w Gdańsku.
Year 2013
-
ANALIZA STANU TECHNICZNEGO RUROCIĄGÓW: WODY PRZeMYSŁOWEJ I SOLANKI
PublicationPracę wykonano na zlecenie Przedsiębiorstwa Badawczo-Wdrożeniowego "HYDRO-POMP" Sp. z o.o. ul. Wróblewskiego 19, 93-578 Łódź. Wykonawcą zlecenia jest Politechnika Gdańska, Wydział Chemiczny, Katedra Elektrochemii, Korozji i Inżynierii Materiałowej, 80-233 Gdańsk, ul. G. Narutowicza 11/12. Celem pracy była analiza stanu technicznego i badania dwóch rurociągów: solanki oraz wody przemysłowej. Badania wykonywano w warunkach terenowych...
-
Study of the formation of calcareous deposits on cathodically protected steel in Baltic sea water
PublicationPurpose – The purpose of this paper is to investigate whether the sedimentation of calcareous deposits occurs on cathodically protected steel in Baltic sea water. Design/methodology/approach – Steel electrodes were cathodically polarized in natural Baltic sea water at potential þ0.150 V vs Zn electrode in potentiostatic mode. During exposure chronoamperometric measurements were carried out. After the exposure, the electrode’s surface...
seen 877 times