Compression test results of fused filamend fabricated polylactyde and polylactyde with carbon fiber filler - Open Research Data - Bridge of Knowledge

Search

Compression test results of fused filamend fabricated polylactyde and polylactyde with carbon fiber filler

Description

The DataSet contains the results of the mechanical behaviour of cube specimens with dimensions 30 x 30 x 30 cm3. The specimens were additively manufactured with the fused filament fabrication (FFF) method. They used two different materials polylactide (PURE PLA) and polylactide with carbon fibre filler (PLA+CF). The specimens were segregated into three groups - unsterilized, plasma-sterilized and ethylene oxide-sterilized. In each group, specimens were investigated before hydrolytic degradation (W0) and after a specified degradation period (W1-W12). The compression test was performed using a Zwick/Roell Z100 universal testing machine (UTM). The parameters of the test were: a preload of 50 N, and a constant mid-span displacement increment of 2 mm/min. The tests were stopped after 4 mm of traverse displacement. The UTM file has (.txt) extension and contains the time of the test (in s, 1st column), force (in N, 3rd column), and traverse displacement (in mm, 4th column).

Dataset file

Compression specimens_Dataset.zip
37.2 MB, S3 ETag 7d4dba2445a1ccc67515af1a546cda58-1, downloads: 8
The file hash is calculated from the formula
hexmd5(md5(part1)+md5(part2)+...)-{parts_count} where a single part of the file is 512 MB in size.

Example script for calculation:
https://github.com/antespi/s3md5
request access

File details

License:
Restricted access
Restricted until published
Raw data:
Data contained in dataset was not processed.

Details

Year of publication:
2022
Verification date:
2022-10-03
Dataset language:
English
Fields of science:
  • Civil engineering and transport (Engineering and Technology)
DOI:
DOI ID 10.34808/ra4y-t973 open in new tab
Funding:
Verified by:
Gdańsk University of Technology

Keywords

Cite as

seen 160 times