Print BestFit End Effects Report

CARE® BQR, FMECA Ver.8.900

End Effects Report

File : PRSMT_EE.html , Date : 04/10/13 , Time : 08:59:16

Master Project Name-Pressure MeterMission Name-Storm on Beach
FMECA Project Name-PRSMTPhase Name-Flight
Phase Time [hrs]-t=100000.00
Project Notes-FMECA Example

Report performed for Block Pressure meter and its subtree




##End Effect NameSeveritySystem Failure Rate [F/10^6Hrs]End Effect Ratio (Alpha)End Effect Rate [F/10^6Hrs]End Effect Ratio for SeverityEnd Effect Probability

a

b

c

d

e

f

g

h

1

False Green

I

3.08465

0.308902

0.952855

1.000000

0.0819907

2

False Red

II

3.08465

0.308643

0.952055

1.000000

0.081922

3

No Indication

III

3.08465

0.358222

1.10499

0.936639

0.0950816

4

Red+Green

III

3.08465

0.024233

0.07475

0.063361

0.00643208

Total1.0000003.08465 


SeveritySeverity Rate [F/10^6Hrs]Ratio [%]Severity Description

i

j

k

l

I

0.952855

30.89

Catastrophic - A failure which may cause death or system loss.

II

0.952055

30.86

Critical - A failure which may cause severe injury, major property damage, or major system damage which will result in mission loss.

III

1.17974

38.25

Marginal - A failure which may cause minor injury/property/system damage which will result in delay or lost of availability or mission degradation.

IV

---------

------

Minor - A failure not serious enough to cause injury, property damage, or system damage, but which will result in unscheduled maintenance or repair.

V

---------

------

User defined.
Total3.08465100.00-

For explanations click here

End of Report