A rapid-response ultrasensitive biosensor for influenza virus detection using antibody modified boron-doped diamond
Abstract
According to the World Health Organization (WHO), almost 2 billion people each year are infected worldwide with flu-like pathogens including influenza. This is a contagious disease caused by viruses belonging to the family Orthomyxoviridae. Employee absenteeism caused by flu infection costs hundreds of millions of dollars every year. To successfully treat influenza virus infections, detection of the virus during the initial development phase of the infection is critical, when tens to hundreds of virus-associated molecules are present in the patient’s pharynx. In this study, we describe a novel universal diamond biosensor, which enables the specific detection of the virus at ultralow concentrations, even before any clinical symptoms arise. A diamond electrode is surface-functionalized with polyclonal anti-M1 antibodies, which then serve to identify the universal biomarker for the influenza virus, M1 protein. The absorption of the M1 protein onto anti-M1 sites of the electrode change its electrochemical impedance spectra. We achieved a limit of detection of 1 fg/ml in saliva buffer for the M1 biomarker, which corresponds to 5–10 viruses per sample in 5 minutes. Furthermore, the universality of the assay was confirmed by analyzing different strains of influenza A virus.
Citations
-
1 0 6
CrossRef
-
0
Web of Science
-
1 0 4
Scopus
Authors (12)
Cite as
Full text
- Publication version
- Accepted or Published Version
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuł w czasopiśmie wyróżnionym w JCR
- Published in:
-
Scientific Reports
no. 7,
pages 1 - 10,
ISSN: 2045-2322 - Language:
- English
- Publication year:
- 2017
- Bibliographic description:
- Nidzworski D., Katarzyna S., Niedziałkowski P., Bogdanowicz R., Sobaszek M., Ryl J., Weiher P., Sawczak M., Wnuk E., Goddard Iii W. A., Jaramillo-Botero A., Ossowski T.: A rapid-response ultrasensitive biosensor for influenza virus detection using antibody modified boron-doped diamond// Scientific Reports. -Vol. 7, iss. 1 (2017), s.1-10
- DOI:
- Digital Object Identifier (open in new tab) 10.1038/s41598-017-15806-7
- Bibliography: test
-
- Peduru Hewa, T. M., Tannock, G. A., Mainwaring, D. E., Harrison, S. & Fecondo, J. V. The detection of influenza A and B viruses in clinical specimens using a quartz crystal microbalance. J. Virol. Methods 162, 14-21 (2009). open in new tab
- Su, L.-C. et al. Rapid and Highly Sensitive Method for Influenza A (H1N1) Virus Detection. Anal. Chem. 84, 3914-3920 (2012). open in new tab
- Lee, D., Chander, Y., Goyal, S. M. & Cui, T. Carbon nanotube electric immunoassay for the detection of swine influenza virus H1N1. Biosens. Bioelectron. 26, 3482-3487 (2011). open in new tab
- Qi, C. et al. Detection of avian influenza virus subtype H5 using a biosensor based on imaging ellipsometry. Biosens. Bioelectron. 25, 1530-1534 (2010). open in new tab
- Farris, L. R. et al. Immuno-interferometric sensor for the detection of influenza A nucleoprotein. Anal. Bioanal. Chem. 396, 667-674 (2009). open in new tab
- Singh, R., Hong, S. & Jang, J. Label-free Detection of Influenza Viruses using a Reduced Graphene Oxide-based Electrochemical Immunosensor Integrated with a Microfluidic Platform. Sci. Rep. 7, srep42771 (2017). open in new tab
- Matsubara, T. et al. Highly sensitive detection of influenza virus by boron-doped diamond electrode terminated with sialic acid- mimic peptide. Proc. Natl. Acad. Sci. 113, 8981-8984 (2016). open in new tab
- Matrosovich, M. & Klenk, H.-D. Natural and synthetic sialic acid-containing inhibitors of influenza virus receptor binding. Rev. Med. Virol. 13, 85-97 (2003). open in new tab
- Hatano, K., Matsuoka, K. & Terunuma, D. Carbosilane glycodendrimers. Chem. Soc. Rev. 42, 4574-4598 (2013). open in new tab
- Chrouda, A. et al. Electrically addressable deposition of diazonium-functionalized antibodies on boron-doped diamond microcells for the detection of ochratoxin A. Anal. Methods 7, 2444-2451 (2015). open in new tab
- Nebel, C. E. et al. Diamond nano-wires, a new approach towards next generation electrochemical gene sensor platforms. Diam. Relat. Mater. 18, 910-917 (2009). open in new tab
- Qureshi, A., Kang, W. P., Davidson, J. L. & Gurbuz, Y. Review on carbon-derived, solid-state, micro and nano sensors for electrochemical sensing applications. Diam. Relat. Mater. 18, 1401-1420 (2009). open in new tab
- Enache, T. A. & Oliveira-Brett, A. M. Boron doped diamond and glassy carbon electrodes comparative study of the oxidation behaviour of cysteine and methionine. Bioelectrochemistry 81, 46-52 (2011). open in new tab
- Bai, Y. et al. Surface Modification for Enhancing Antibody Binding on Polymer-Based Microfluidic Device for Enzyme-Linked Immunosorbent Assay. Langmuir 22, 9458-9467 (2006). open in new tab
- Nidzworski, D., Pranszke, P., Grudniewska, M., Król, E. & Gromadzka, B. Universal biosensor for detection of influenza virus. Biosens. Bioelectron. 59, 239-242 (2014). open in new tab
- Yang, L. & Bashir, R. Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria. Biotechnol. Adv. 26, 135-150 (2008). open in new tab
- Yun, Y.-H., Bhattacharya, A., Watts, N. B. & Schulz, M. J. A Label-Free Electronic Biosensor for Detection of Bone Turnover Markers. Sensors 9, 7957-7969 (2009). open in new tab
- Guo, X. et al. Carbohydrate-Based Label-Free Detection of Escherichia coli ORN 178 Using Electrochemical Impedance Spectroscopy. Anal. Chem. 84, 241-246 (2012). open in new tab
- Huang, Y., Bell, M. C. & Suni, I. I. Impedance Biosensor for Peanut Protein Ara h 1. Anal. Chem. 80, 9157-9161 (2008). open in new tab
- Spackman, E. & Suarez, D. L. Type A influenza virus detection and quantitation by real-time RT-PCR. Methods Mol. Biol. Clifton NJ 436, 19-26 (2008). open in new tab
- Francis, T. & Magill, T. P. Direct Isolation of Human Influenza Virus in Tissue Culture Medium and on Egg Membrane. Exp. Biol. Med. 36, 134-135 (1937). open in new tab
- Pachucki, C. T., Khurshid, M. A. & Nawrocki, J. Utility of Reverse Transcriptase PCR for Rapid Diagnosis of Influenza A Virus Infection and Detection of Amantadine-Resistant Influenza A Virus Isolates. J. Clin. Microbiol. 42, 2796-2798 (2004). open in new tab
- Coonrod, J. D., Karathanasis, P., Betts, R. F. & Donofrio, J. C. Enzyme-linked immunosorbent assay of core antigens for clinical diagnosis of influenza. J. Med. Virol. 25, 399-409 (1988). open in new tab
- Babin, S. M., Hsieh, Y.-H., Rothman, R. E. & Gaydos, C. A. A Meta-analysis of Point-of-care Laboratory Tests in the Diagnosis of Novel 2009 Swine-lineage Pandemic Influenza A(H1N1). Diagn. Microbiol. Infect. Dis. 69, 410-418 (2011). open in new tab
- Singh, R. & Suni, I. I. Minimizing Nonspecific Adsorption in Protein Biosensors that Utilize Electrochemical Impedance Spectroscopy. J. Electrochem. Soc. 157, J334-J337 (2010). open in new tab
- Lee, J. A. et al. An electrochemical impedance biosensor with aptamer-modified pyrolyzed carbon electrode for label-free protein detection. Sens. Actuators B Chem. 129, 372-379 (2008). open in new tab
- Li, C. M. et al. Impedance labelless detection-based polypyrrole protein biosensor. Front. Biosci. J. Virtual Libr. 10, 2518-2526 (2005). open in new tab
- Shang, F. et al. Selective Nanomolar Detection of Dopamine Using a Boron-Doped Diamond Electrode Modified with an Electropolymerized Sulfobutylether-β-cyclodextrin-Doped Poly(N-acetyltyramine) and Polypyrrole Composite Film. Anal. Chem. 81, 4089-4098 (2009). open in new tab
- Weng, J. et al. Label-Free DNA Sensor by Boron-Doped Diamond Electrode Using an ac Impedimetric Approach. Anal. Chem. 80, 7075-7083 (2008). open in new tab
- Zhou, Y. L., Tian, R. H. & Zhi, J. F. Amperometric biosensor based on tyrosinase immobilized on a boron-doped diamond electrode. Biosens. Bioelectron. 22, 822-828 (2007). open in new tab
- Ho, J. A. et al. Ultrasensitive electrochemical detection of biotin using electrically addressable site-oriented antibody immobilization approach via aminophenyl boronic acid. Biosens. Bioelectron. 26, 1021-1027 (2010). open in new tab
- Polsky, R. et al. Electrically addressable diazonium-functionalized antibodies for multianalyte electrochemical sensor applications. Biosens. Bioelectron. 23, 757-764 (2008). open in new tab
- Scientific RepoRts | 7: 15707 | DOI:10.1038/s41598-017-15806-7 open in new tab
- Radhakrishnan, R., Suni, I. I., Bever, C. S. & Hammock, B. D. Impedance Biosensors: Applications to Sustainability and Remaining Technical Challenges. ACS Sustain. Chem. Eng. 2, 1649-1655 (2014). open in new tab
- Ruigrok, R. W. H. et al. Membrane Interaction of Influenza Virus M1 Protein. Virology 267, 289-298 (2000). open in new tab
- Verified by:
- Gdańsk University of Technology
seen 252 times
Recommended for you
Biomolecular influenza virus detection based on the electrochemical impedance spectroscopy using the nanocrystalline boron-doped diamond electrodes with covalently bound antibodies
- K. Siuzdak,
- P. Niedziałkowski,
- M. Sobaszek
- + 7 authors
Ligand-Modified Boron-Doped Diamond Surface: DFT Insights into the Electronic Properties of Biofunctionalization
- B. Dec,
- M. Sobaszek,
- A. Jaramillo-botero
- + 2 authors