Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples
Abstract
The aim of the study was to develop an automated computer-aided system for analysis of spectrograms obtained from measurements of biological samples performed with a low-coherence Fabry-Pérot interferometer. Information necessary to determine dispersion characteristics of measured materials can be calculated from the positions of the maxima and minima that are present in their spectra. The main challenge faced during the development of the system was reliable detection of these maxima and minima in the presence of noise, without requiring substantial user interaction, and with an acceptable computational complexity.
Citations
-
0
CrossRef
-
0
Web of Science
-
0
Scopus
Authors (3)
Cite as
Full text
- Publication version
- Accepted or Published Version
- License
- Copyright (2016 SPIE)
Keywords
Details
- Category:
- Conference activity
- Type:
- materiały konferencyjne indeksowane w Web of Science
- Title of issue:
- Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2016 strony 1 - 7
- ISSN:
- 0277-786X
- Language:
- English
- Publication year:
- 2016
- Bibliographic description:
- Mrotek M., Pluciński J., Jędrzejewska-Szczerska M..: Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples, W: Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2016, 2016, SPIE-INT SOC OPTICAL ENGINEERING,.
- DOI:
- Digital Object Identifier (open in new tab) 10.1117/12.2249192
- Bibliography: test
-
- P Wierzba, M J¦drzejewska-Szczerska, "Optimization of a Fabry-Perot Sensing Interferometer Design for an Optical Fiber Sensor of Hematocrit Level", Acta Physica Polonica, A. 124 (3) open in new tab
- K Karpienko, M Gnyba, D Milewska, MS Wróbel, ..., "Blood equivalent phantom vs whole human blood, a comparative study", Journal of Innovative Optical Health Sciences 9 (02), 1650012 open in new tab
- D Milewska, K Karpienko, M J¦drzejewska-Szczerska, "Application of thin diamond lms in low-coherence ber-optic Fabry Pérot displacement sensor", Diamond and Related Materials 64, 169-176 open in new tab
- D Majchrowicz, M Hirsch, P Wierzba, M Bechelany, R Viter, ..., "Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers", Sensors 16 (3), 416 open in new tab
- Biosensors for Security and Bioterrorism Applications, Dimitrios P. Nikolelis, Georgia-Paraskevi Nikoleli, [ed], 2016 Springer open in new tab
- M. Born, E. Wolf, Principles of Optics (7th (expanded) edition), Cambridge University Press 2006.
- J. Goodman, Statistical Optics, Wiley Classics, 2000
- "Find local maxima", (accessed 27.06.2016). [http://www.mathworks.com/help/signal/ref/ndpeaks.html] open in new tab
- F. Marvasti, Nonuniform sampling: Theory and Practice, Plenum Publishers Co., 2001 open in new tab
- K. Turkowski, S. Gabriel, "Filters for Common Resampling Tasks", Graphics Gems I. Academic Press. pp. 147165. 1990. open in new tab
- Verified by:
- Gdańsk University of Technology
seen 64 times
Recommended for you
Nitrogen-Doped Diamond Film for Optical Investigation of Hemoglobin Concentration
- D. Majchrowicz,
- M. Kosowska,
- K. J. Sankaran
- + 5 authors