Dynamic state assessment of the water turbine with the power of 600 kW - Publication - Bridge of Knowledge

Search

Dynamic state assessment of the water turbine with the power of 600 kW

Abstract

The article discusses the results of experimental studies to assess the dynamic state of the turbine set with the Kaplan turbine. The dynamic assessment was made on the basis of appropriate standards, based on the measurement results of selected parameters of vibration, which have been measured for several states of the machine load. In addition, we attempted to identify the causes of the increased vibration levels based on the measured vibration spectrum and the temperature distribution on the machine casing. On the basis of analysis results, the tested fluid-flow machine was qualified in the appropriate zone (defining the state of vibration) and identified the source of high levels of vibration.

Authors (3)

  • Photo of  Grzegorz Żywica

    Grzegorz Żywica

    • Instytut Maszyn Przepływowych PAN Zakład Dynamiki Wirników i Łożysk Ślizgowy
  • Photo of  Paweł Bagiński

    Paweł Bagiński

    • Instytut Maszyn Przepływowych PAN Zakład Dynamiki Wirników i Łożysk Ślizgowy
  • Photo of  Łukasz Breńkacz

    Łukasz Breńkacz

    • Instytut Maszyn Przepływowych PAN Zakład Dynamiki Wirników i Łożysk Ślizgowy

Cite as

Full text

download paper
downloaded 44 times
Publication version
Accepted or Published Version
License
Creative Commons: CC-BY open in new tab

Keywords

Details

Category:
Articles
Type:
artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
Published in:
Diagnostyka no. 14, pages 65 - 70,
ISSN: 1641-6414
Language:
English
Publication year:
2013
Bibliographic description:
Żywica G., Bagiński P., Breńkacz Ł.: Dynamic state assessment of the water turbine with the power of 600 kW// Diagnostyka. -Vol. 14., iss. 1 (2013), s.65-70