Highly selective impedimetric determination of Haemophilus influenzae protein D using maze-like boron-doped carbon nanowall electrodes
Abstract
This study reports a novel impedimetric immunosensor for protein D detection in purified and bacterial (Haemophilus influenzae, Hi) samples. The detection was based on antigen recognition by anti-protein D antibodies (apD) immobilised at the maze-like boron-doped carbon nanowall electrodes (B:CNW). The B:CNW electrodes were synthesised, and their surface was characterised by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) methods. The sensor was prepared in a two-step procedure: apD were covalently linked on the previously modified B:CNW electrodes using diazonium salt. Modification steps were controlled by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) measurements. The immunosensor exhibited excellent electrochemical performance, stability, satisfactory sensitivities, and linear ranges for antigen detection. Protein D was detected down to 2.39×102 fg/mL with a linear range extending from 3.37×10-11 to 3.37×10-3 μg/mL (in purified sample). Next, Hi’s LOD was 5.20×102 CFU/mL with a linear range of 8.39×101–8.39×103 CFU/mL. Selectivity studies showed no reaction with negative samples as Streptococcus pyogenes, Streptococcus pneumoniae or Bordetella parapertussis bacteria. Therefore, the new approach is suitable for rapid and quantitative detection of Hi, and is a good candidate for further tests on clinical samples.
Citations
-
1 6
CrossRef
-
0
Web of Science
-
1 7
Scopus
Authors (13)
Cite as
Full text
- Publication version
- Accepted or Published Version
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuły w czasopismach
- Published in:
-
TALANTA.The International Journal of Pure and Applied Analytical Chemistry
no. 221,
ISSN: 0039-9140 - Language:
- English
- Publication year:
- 2021
- Bibliographic description:
- Brodowski M., Kowalski M., Skwarecka M., Pałka K., Skowicki M., Kula A., Lipiński T., Dettlaff A., Ficek M., Ryl J., Dziąbowska K., Nidzworski D., Bogdanowicz R.: Highly selective impedimetric determination of Haemophilus influenzae protein D using maze-like boron-doped carbon nanowall electrodes// TALANTA.The International Journal of Pure and Applied Analytical Chemistry -Vol. 221, (2021), s.121623-
- DOI:
- Digital Object Identifier (open in new tab) 10.1016/j.talanta.2020.121623
- Verified by:
- Gdańsk University of Technology
seen 183 times
Recommended for you
Detection of the Plant Pathogen Pseudomonas Syringae pv. Lachrymans on Antibody-Modified Gold Electrodes by Electrochemical Impedance Spectroscopy
- Z. Cebula,
- S. Żołędowska,
- K. Dziąbowska
- + 8 authors