Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
Abstract
Lead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination of Pb(II) at high concentrations of interfering ions, such as Na(I), Cu(II), Cd(II), Zn(II), Mg(II) and Ca(II). The potentiometric response of ionophore-based Pb(II)-ISEs was compared to that of a solid-state crystalline Pb(II)-ISE for Na+, Cu2+, Cd2+ and Zn2+. Determination of lead(II) by ion-selective electrodes was compared to measurements done by atomic absorption spectroscopy. Comparable concentrations of lead were obtained by both techniques, which indicate the possibility to apply such ion-selective electrodes for monitoring of lead in e.g. Zn–Pb mines where the concentration of zinc may be high compared to lead.
Citations
-
4 0
CrossRef
-
0
Web of Science
-
4 4
Scopus
Authors (6)
Cite as
Full text
full text is not available in portal
Keywords
Details
- Category:
- Articles
- Type:
- artykuł w czasopiśmie wyróżnionym w JCR
- Published in:
-
SENSORS AND ACTUATORS B-CHEMICAL
no. 218,
pages 25 - 30,
ISSN: 0925-4005 - Language:
- English
- Publication year:
- 2015
- Bibliographic description:
- Jasiński A., Guziński M., Lisak G., Bobacka J., Bocheńska M.: Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)// SENSORS AND ACTUATORS B-CHEMICAL. -Vol. 218, (2015), s.25-30
- DOI:
- Digital Object Identifier (open in new tab) 10.1016/j.snb.2015.04.089
- Verified by:
- Gdańsk University of Technology
seen 239 times
Recommended for you
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
- M. Urbanowicz,
- K. Sadowska,
- D. G. Pijanowska
- + 2 authors
Lead(II)-selective ionophores for ion-selective electrodes: A review
- M. Guziński,
- G. Lisak,
- J. Kupis
- + 2 authors
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 16. Synthesis of 25, 26, 27, 28-tetrakis(piperidinethiocarbonylmethylene)-p-tert-butylcalix[4]arene and its interaction with metal ions
- J. Kulesza,
- M. Guziński,
- V. Hubscher-Bruder
- + 2 authors