Abstract
This paper demonstrates the assessment of vibrational spectroscopy methods such as middle infrared, near infrared and Raman spectroscopy (FTIR, FT-NIR, Raman) for the identification of pseudopolymorphic forms of a model active pharmaceutical ingredient (API) - sodium naproxen (NpxNa). NpxNa, in the form of three different pseudopolymorphs, was investigated by methods dedicated for solid state characterization: DSC (differential scanning calorimetry), XPRD (powder X-ray diffraction), SEM (scanning electron
microscopy) and Karl Fischer titration. Novelty in the results sourced in the usage of the method not applied so far to identify pseudopolymorphic forms of NpxNa, that is, FTIR and FT-NIR. Based on the obtained reproduceable results, various pseudopolymorphic forms were successfully evaluated.
Spectroscopic data were correlated with DSC and XPRD results. It was concluded that the combination of band’s variations visible on the spectra of pseudopolymorphic forms will allow to interpretate the results unequivocally in case of crucial stability tests of medicinal substance or during on-line pharmaceutical process development by FTIR, FT–NIR and Raman spectroscopy
Citations
Authors (3)
Cite as
Full text
full text is not available in portal
Details
- Category:
- Magazine publication
- Type:
- Magazine publication
- Published in:
-
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY
no. 261,
pages 1 - 9,
ISSN: 1386-1425 - Publication year:
- 2021
- DOI:
- Digital Object Identifier (open in new tab) https://doi.org/10.1016/j.saa.2021.120018
- Verified by:
- No verification
seen 96 times
Recommended for you
FTIR, Raman spectroscopy and HT-XRD in compatibility study between naproxen and excipients
- B. Rojek,
- M. Gazda,
- A. Plenis