Filters
total: 1238
filtered: 234
Search results for: GRAVITY, SEA MEASUREMENTS, EARTH, GEOLOGIC MEASUREMENTS, SEA SURFACE, MATHEMATICAL MODEL
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 300 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 270 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 190 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 260 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 290 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Electrical conductivity relaxation measurements - water uptake of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataFor Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ sample was measured in the ProboStat™ measurement system. The ECR measurements were performed in air in the temperature range of 450-800 ℃ after switching water partial pressure between...
-
Electrical conductivity relaxation measurements - oxidation and reduction of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataThe dataset consists of 2 main catalogs: measurements performed for oxidation/reduction in dry conditions and in humid conditions. For Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the sample was measured in the ProboStat™ measurement system. The ECR measurements were...
-
Photos and movies regarding the dome's real-life model assembly and tests
Open Research DataThis dataset consists of an archive with the photos and movies regarding the dome's real-life model assembly and tests.
-
The initial FEM model of the dome assembled in SOFiSTiK FEA (2020) software
Open Research DataThis dataset consists of an archive with the (selected) files of the initial FEM model of the dome assembled in SOFiSTiK FEA (2020) software.
-
XRD file presenting phase purity of the SiC wick material
Open Research DataA file presents X-ray diffraction (XRD) analysis in the 10–90° range to verify the phase purity of the wick material. The measurements were performed on the exposed surface of the cylindrical sample. The XRD diffractogram of the SiC sample was measured in an air atmosphere.
-
XRD file presenting phase purity of the SS316L wick material
Open Research DataA file presents X-ray diffraction (XRD) analysis in the 10–90° range to verify the phase purity of the wick material. The measurements were performed on the exposed surface of the cylindrical sample. The XRD diffractogram of the SS316L sample was measured in an air atmosphere.
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 130 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 120 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 100 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 110 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Depth profile of the gold-silver bimetallic structures
Open Research DataSilver and gold bimetallic layers were deposited on a silicon substrate by magnetron sputtering method. Both, Au and Ag layers had 3 nm of thickness. That prepared nanostructures were measured by XPS method. To obtain a depth profile of chemical composition, an Argon ion (Ar+) gun was used for etching surface of sample. Each cycle of etching takes 30...
-
Electrical and noise responses of graphene back-gated field-effect transistors enhanced by UV light for organic vapors sensing
Open Research DataBack-gated field-effect transistors with graphene channels (GFETs) were investigated toward organic vapors sensing. Two methods were used for sensing experiments including DC characteristics measurements and fluctuation-enhanced sensing by low-frequency noise studies. The data set consists of raw and modified data on GFET responses to acetonitrile,...
-
Cyclic voltammetry curves for FTO/PANI:WO3 nanocomposite
Open Research DataThis dataset contains the results of kinetic electrochemical studies, carried out with cyclic voltammetry (CV) of FTO/PANI:WO3 nanocomposite at various scan rates: 10, 20, 50, 75, 100 and 200 mV/s. The electrolyte was 1M H2SO4 solution. The measurements were performed in a three electrode setup, and with Ag|AgCl|3M KCl as the reference electrode and...
-
Electrical conductivity relaxation measurements - water uptake and oxidation of BaCe0.6Zr0.2Y0.2-xFexO3-δ (x = 0.02, 0.05, 0.1)
Open Research DataThe dataset consists of 2 main catalogs: measurements performed for oxidation/reduction (Oxidation) and hydration/dehydration (Hydration). Each of them consists individual catalogs for the measurements performed on the samples indicated by the name of the catalog. In the case of oxidation/reduction, inside each them, there are catalogs indicating if...
-
The time-varying low-frequency magnetic-field emitted from the ship’s inverter-fed induction motor
Open Research DataThe dataset contains the magnetic field measurement results that are part of a comprehensive study on the assessment of the magnetic field emissions onboard of the research-training vessel. The measurements were carried out, nearby the bow thruster motor fed from the inverter, during maneuvering and the sea voyage. The bow thruster is assembled in the...
-
Depth profile of the chemical composition of the Au-Ag multilayers
Open Research DataSilver and gold multilayers were deposited on a silicon substrate by magnetron sputtering method. Both type, Au and Ag thin films had 2 nm of thickness. Totally structure had thickness of 6 nm (Au-Ag-Au). That prepared multilayers were measured by XPS method. To obtain a depth profile of chemical composition, an Argon ion (Ar+) gun was used for etching...
-
Magnetic field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz – spatial detection
Open Research DataThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
Integrated circuit structure surface images obtained with contact capacitive imaging technique
Open Research DataThe measurements were done using NTEGRA Prima (NT-MDT) device. CSG 10Pt probe.
-
The electromagnetic field intensity in industrial buildings
Open Research DataThe dataset contains the results of measurements of electromagnetic fields, separately electric and magnetic, carried out at selected places in the building of an operating industrial enterprise.
-
Measurement file of PEEK 70 mm bushing measurements in original condition perforemed on custom-built 3d measuring stand
Open Research DataAfter manufacturing process (lathe turning) bearing was measured on custom bulit measurement stan developed during research project financed by National Centre of Science. Measurements consist of 110 000 points in 3D space taken on bushing inner surface. Bearing was measured taking vertical steps of 0,2 mm.
-
Statistics of AFM current-voltage curves
Open Research DataMapping surface electrical conductivity offers enormous cognitive possibilities regarding the structure and properties of modern materials. The technique invented for this purpose (Conductive AFM) by Murrel's team and colleagues allows independent monitoring of the local conductivity of materials in correlation with the topographic profile. The mentioned...
-
Images of topography and mechanical properties (phase imaging) of cast iron samples from water installations
Open Research DataMeasurements in contact and semi-contact mode. NTEGRA Prima (NT-MDT) device. CSG 10.
-
The magnetic field measurements in selected places of the industrial building
Open Research DataThe dataset is part of a comprehensive study on the assessment of the electromagnetic field intensity in a building of an operating industrial plant. Detailed results of magnetic field measurements, carried out in selected places of this building, are presented.
-
XLS file with the initial data on the dome's geometry outline
Open Research DataThis dataset consists of an XLS file with the initial data on the dome's geometry outline.
-
Autodesk AUTOCAD file with the dome's geometry outline
Open Research DataThis dataset consists of an Autodesk AUTOCAD file with the dome's geometry outline.The studies carried out in the "Miniatura 7" scientific grant were devoted to both experimental and theoretical (numerical) measurements executed on a tensegrity dome model (with a Fuller-type grid) to identify the changes in the state of displacements, induced by the...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Magnetic field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz – selective detection
Open Research DataThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
SEMG signal database for the automated upper limb rehabilitation process
Open Research DataAn automated rehabilitation device control system requires information about the patient's physiological condition. This is possible thanks to the use of biological feedback in the form of electromyography and surface signals (Surface Electromyography, SEMG).
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Tagged images with LEGO bricks - Transportation - Sea and Air
Open Research DataThe set contains images of LEGO bricks (from Transportation - Sea and Air category). The images were prepared for training neural network for recognition and labeling of LEGO bricks. The images contain one brick each. The images were taken from different sides by handheld camera hovering over the bricks lying on a white, non reflective surface.
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
The files from COMREL software used in the numerical reliability assessment of the imperfect dome's displacements
Open Research DataThis dataset consists of an archive with the files from COMREL software used in the numerical reliability assessment of the imperfect dome's state of displacements.
-
XLS file with the key results from the experimental analysis of the imperfect dome's state of displacements
Open Research DataThis dataset consists of an XLS file with the key results from the experimental analysis of the imperfect dome's state of displacements.
-
Key results from the numerical FEM analysis of the imperfect dome's state of displacements
Open Research DataThis dataset consists of an XLS file with the key results from the numerical FEM analysis of the imperfect dome's state of displacements.
-
Determination of changes in viscosity of chitosan solutions depending on shear rate.
Open Research DataThe rheological characteristics of chitosan solutions were based on viscosity measurements using a Brookfield viscometer, using LV SC4 - 25 spindles and shear rates from 4 to 53 s-1 (Fig. 1). Chitosan solutions with different molecular weights (low, medium and high) were prepared in concentrations from 1.5 to 3.0% in 0.5M acetic acid. The data allowed...
-
The AFM micrographs and impedance study of epoxy coatings after exposure in corrosive media
Open Research DataThe dataset contains Atomic Force Microscopy (AFM) images and local impedance measurements of epoxy organic coating used as anti-corrosion protection, before and after 2-month exposure to sodium chloride solution. Additionally, there two local impedance spectra recorded after the coating exposure. The first one was recorded on intact coating surface,...
-
Imaging of the effects of pitting corrosion with the use of AFM
Open Research DataPitting corrosion is a local attack on a metal surface, limited to a point or small area, which appears as a hole. Pitting corrosion is one of the most harmful forms of corrosion due to the fact that it is associated with small, difficult to detect damage, that can even lead to perforation of the structure. A single pit may range in size from micrometers...
-
Magnetic field maps of an astable multivibrator in frequency range from 100 kHz to 50 MHz
Open Research DataThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
Electric field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz
Open Research DataThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain electric field maps created on based measurements...
-
Results of timber material tests from a strength testing machine
Open Research DataThis dataset consists of an archive with TRA files with the results of timber (wooden rolls) material tests from an universal strength testing machine.