Filters
total: 652
filtered: 442
-
Catalog
Chosen catalog filters
Search results for: impedance measurements
-
Linearization in impedance measurements
Publication -
Impulse Impedance Measurements of Lightning Protection Earthings
PublicationLightning protection earthing systems should be tested at currents with time parameters similar to those of lightnings. A method and definition of a measured value of impulse impedance are introduced. The impulse impedance was determined by a quotient of voltage drop on the tested earthing to a value of current in measure circuit. The usefulness of the impulse method for lightning protection evaluation is tested on radio base stations...
-
Impedance measurements of coating properties on bridge structures
PublicationPomiary impedancyjne pozwalają na prostą ocenę właściwości ochronnych powłok ochronnych i wykładzin. Pomiary stosuje się w celu porównania powłok, monitorowania ich właściwości i oceny mechanizmu działania. Metodyka jest z powodzeniem stosowana w pomiarach laboratoryjnych. Pomiary terenowe są bardziej skomplikowane ponieważ wymagają w pełni kontrolowanych komputerowo przyrządów, kontroli warunków pogodowych oraz wielu innych parametrów...
-
Impedance measurements of skin layered structure for burns determination.
PublicationW pracy analizowany jest dwuwarstwowy model skóry. Pokazano, że za pomocą wielokrotnych pomiarów immitancyjnych jest możliwe wyznaczenia zarówno parametrów elektrycznych oparzonej skóry jak i geometrycznych. Przedstawiono algorytm estymacji i procedurę pomiarową wyżej wymienionych parametrów.
-
Monitoring of breast tissue thermo-ablation by means of impedance measurements
PublicationW pracy przedstawiono rozważania dotyczące monitorowania jakości termoablacji zmian nowotworowych w piersi przy pomocy pomiarów impedancyjnych. Pokazano prototypowe konstrukcje sond do termoablacji jak również zaprezentowano wyniki symulacji i pierwszych eksperymentów. A usefulness of a developed probe combining power delivery to ablated breast tumour and simultaneous impedance measurements is discussed in the paper. It consists...
-
Optimization of impedance measurements using ‘chirp’ type perturbation signal
Publication -
The application of impedance measurements for the determination of the probability of the course of corrosion processes
Publication -
Optimization of impedance measurements using ''chirp'' type perturbation signal
PublicationW pracy przedstawiono innowacyjny sposób pomiaru impedancji przy użyciu sygnału niestacjonarnego "chirp". W procesie akwizycji pobudzenia i odpowiedzi prądowej zastosowano zmienną częstotliwość próbkowania. Podejście takie pozwala zarówno na wielokrotne zmniejszenie ilości niezbędnych do otrzymania widma impedancyjnego rejestrowanych danych jak również upraszcza i przyspiesza proces obliczeniowy. Stwierdzono iż dokładność wyników...
-
Impedancyjne badanie korozji wżerowej. Impedance measurements of pitting corrosion
PublicationKryteria zachodzenia korozji wżerowej związane są z badaniami tego zjawiska metodą cyklicznej polaryzacji i opierają się na wartości gęstości prądu lub bezwzględnej wartości prądu płynącego w układzie. Na podstawie przeglądu literaturowego wybrano cztery kryteria stosowane przy badaniu stali stopowych metodą cyklicznej polaryzacji. Dla warunków prądowych odpowiadających kryteriom zachodzenia korozji wżerowej przedstawiono widma...
-
A telemedical and an outpatient thoracic impedance measurements - a validation algorithm of the electrodes placement
PublicationThis paper presents the algorithm for validation of electrodes locations for the thoracic impedance measurements. In particular the presented algorithm was designed to perform the telemetric sleep apnea monitoring. One of the problems, during the clinical tests of a developed device, was to preserve the repeatability of measurements. It strongly depended on the appropriate electrodes placement on the examined person’s thorax. It...
-
Determination of time delay between ventricles contraction using impedance measurements
PublicationThe paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on...
-
Galvanostatic impedance measurements for the efficient adsorption isotherm construction in corrosion inhibitor studies
PublicationWe present an approach towards an accurate and time-efficient adsorption isotherm determination to evaluate the corrosion inhibitor interaction in electrolytic environments. The approach is based on dynamic impedance spectroscopy measurements in galvanostatic mode (g-DEIS). The studied corrosion inhibitor is continuously injected between the secondary cell and the corrosion cell. The efficiency corresponding to instantaneous inhibitor...
-
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode.
PublicationThis study presents a novel approach to impedance measurements. The methodology discussed is limited to contact in the sample-probe system under ambient conditions without the presence of electrolyte. Comparison with results of direct and alternating current measurements for well-defined metallic surfaces are made. In spite of idealization related to the type of contact examined, the proposed technique provides an improvement of...
-
Localized impedance measurements of AA2024 and AA2024-T3 performed by means of AFM in contact mode
PublicationPurpose: The purpose of this paper is to present the results of an atomic force microscopy (AFM) based approach to local impedance spectroscopy (LIS) measurement performed on AA2024 and AA2024-T3 aluminium alloys. Design/methodology/approach: AFM-LIS measurements were performed ex-situ without the electrolyte environment, so in fact the electrical not electrochemical impedance was obtained. Findings: Relative local impedance values...
-
Dynamic impedance measurements of the Direct Methanol Fuel Cell cathode at various operating temperatures
PublicationThis article discusses the application of impedance analysis for diagnosing the cathode of a direct methanol fuel cell at various operating temperatures. The Dynamic Electrochemical Impedance Spectroscopy technique coupled with a linear current scan was applied for this purpose. This technique allowed the observation of changes in the cathode's properties in the fuel cell operating under real working conditions. An equivalent model...
-
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode
Publication -
Localized impedance measurements of AA2024 and AA2024‐T3 performed by means of AFM in contact mode
Publication -
Optimization of the Relative Humidity of Reactant Gases in Hydrogen Fuel Cells Using Dynamic Impedance Measurements
PublicationWater management is a key factor affecting the efficiency of proton exchange membrane fuel cells (PEMFCs). The currently used monitoring methods of PEMFCs provide limited information about which processes or components that humidity has a significant impact upon. Herein, we propose the use of a novel approach of impedance measurements using a multi-sinusoidal perturbation signal, which enables impedance measurements under dynamic...
-
The fixed state in impedance measurements of a two-step electrode reaction proceeding with accompanying adsorption of an intermediate product
Publication -
Reassesing whole tooth electrical impedance spectroscopy measurements
PublicationW pracy dokonano krytycznej oceny wyników wcześniejszych badań spektorskopowych zębów przeprowadzonych w innych ośrodkach i porównano je z własnymi. Wskazano na trudności występujące podczas pomiarów.
-
Monitoring of CRT by means of impedance multiple measurements - simulation studies
PublicationCardiac resynchronization therapy (CRT) is a very promising treatment for patients with congestive heart failure. An Impedance Cardiography (ICG) is used for evaluation of heart mechanical activity. A simulation study with the use of a FEM model was performed. The developed realistic model of the thorax, based on CT data obtained from examination of a 68-year-old man, consisted of 212 000 tetrahedral elements. Different configurations...
-
Corrosion rate measurements by non-linear electrochemical impedance spectroscopy
Publication -
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stanless steel
PublicationPraca prezentuje wyniki badań uzyskane z pomiarów techniką lokalnej spektroskopii impedancyjnej (LIS) wykonanych w trybie kontaktowym mikroskopii sił atomowych (AFM), które zostały przeprowadzone w lokalnych obszarach powierzchni ziarna austenitu i na granicy ziarna austenitu wysokostopowej stali austenitycznej AISI 304 poddanej procesowi uczulania oraz na próbkach odniesienia nie poddanych obróbce cieplnej.Badania LIS-AFM były...
-
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stainless steel
Publication -
Three modes of electrochemical impedance spectroscopy measurements performed on vanadium redox flow battery
PublicationThis article presents an innovative approach to monitor working redox flow batteries using dynamic electrochemical impedance spectroscopy, diverging from the commonly sequential impedance methods carried out under potentiostatic or galvanostatic conditions close to the open circle voltage. The authors introduce a fresh variation of dynamic impedance measurement that leverages an amplitude-modulated multi-frequency alternating current...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses
Publication -
Dynamic elektrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublicationDynamiczna elektrochemiczna spektroskopia impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublicationDynamiczna Elektrochemiczna Spektroskopia Impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Simultaneous impedance and volumetric studies and additionally potentiodynamic polarization measurements of molasses as a carbon steel corrosion inhibitor in 1M hydrochloric acid solution
PublicationThe inhibition effect of molasses on the corrosion of low carbon steel in 1M hydrochloric acid solution was investigated by volumetric and electrochemical measurements. Potentiodynamic polarization and dynamic electrochemical impedance spectroscopy (DEIS) results were obtained and compared with to those, obtained with the hydrogen evolution technique. All results indicate that molasses functioned as a good inhibitor in 1M hydrochloric...
-
Polynomial analysis as a new way of describing dynamic impedance spectra – Differential and relative impedance spectra
PublicationModel measurements of an equivalent electrical system were carried out using the technique of Dynamic Electrochemical Impedance Spectroscopy. The measurement took the form of potentiodynamic changes imposed on the tested system. Using the possibility of continuous impedance measurements, an attempt was made to develop an original and innovative method of analyzing impedance spectrograms, which is termed polynomial analysis. As...
-
The Influence of Thin Gold Electrodes on the High-Temperature Impedance of Oxide Glasses
PublicationThe influence of thin gold electrodes on the electrical measurements of glasses at high temperatures was studied using impedance spectroscopy. The impedance was measured several times over a wide frequency range from 10 mHz to 1 MHz and the temperature ranged from 213 to 673 K under air and nitrogen atmospheres. The results showed a drop in the conductivity of more than an order of magnitude at a temperature around 603 K during...
-
Assessment of organic coating degradation via local impedance imaging
PublicationThe paper presents a new approach to organic coating condition evaluation at micrometer scale using localized impedance measurements. It is based on atomic force microscopy (AFM) in contact mode. Impedance is measured between conductive AFM tip and metal substrate covered with organic coating. A single-frequency voltage perturbation signal is applied between the electrodes and current response signal is registered. As the tip is...
-
Local electrochemical impedance spectroscopy in dynamic mode of galvanic coupling
PublicationA novel method that combines local electrochemical impedance spectroscopy and mapping in dynamicmode is proposed. Method was validated over two galvanic couplings, namely zinc/copper and cad-mium/copper. Impedance spectrum response for all measuring points was obtained by means ofsimultaneous implementation of selected range of frequencies. Proposed method allows the measure-ment in a more time-efficient manner, at the same time...
-
Polynomial description of dynamic impedance spectrogram—introduction to a new impedance analysis method
PublicationThis paper presents a polynomial description of spectrograms obtained using Dynamic Electrochemical Impedance Spectroscopy. A method to fit the polynomial degree correctly is discussed. A simple electrical system of a diode connected in parallel with a capacitor was used for testing. Dynamic impedance measurements during potentiodynamic polarization were conducted. This paper presents an alternative analysis method that allows...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublicationIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Validation of dynamic electrochemical impedance spectrograms using autocorrelation function
PublicationValidation of impedance data is essential for checking the reliability of experimental data. Kramers – Kronig transformation is used to verify data obtained from classical Electrochemical Impedance Spectroscopy (EIS) measurements. Data obtained from Dynamic Electrochemical Impedance Spectroscopy (DEIS) could be validated in the same way, but in this case, there is no information about internal consistency between every single spectrum...
-
Impedance of cation-coupled electron transfer reaction: Theoretical description of one pathway process
PublicationIt has been assumed that cation electron coupled charge transfer can be conducted in accordance with two mutually coupled reactions. Using a differential method an expression was introduced which describes the impedance of a cation electron coupled transfer reaction. Also, an electrical equivalent circuit has been defined. The total faradaic impedance is the sum of electron transfer impedance and cation transfer impedance. Issues...
-
Application of different modes of nanoscale impedance microscopy in materials research
PublicationIn recent years, there is noticeable interest in application of various types of scanning probe microscopy in material science research. One of them is contact atomic force microscopy combined with local impedance measurements, known as nanoscale impedance microscopy. Literature references present its application in investigations of new materials, microelectronics diagnostics, or research of protective coatings performance. In...
-
Study of Direct Methanol Fuel Cell Process Dynamics Using Dynamic Electrochemical Impedance Spectroscopy
PublicationA new technique, which was developed to characterize the direct methanol fuel cell under work conditions, has been presented in this paper. The impedance measurements were made using dynamic electrochemical impedance spectroscopy research technique in the galvanostatic mode, using multiple sinusoidal excitation. Obtained results show, that together with an increase of the temperature and working load, the global impedance...
-
Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes
PublicationThe most common method of determination of cavitation erosion resistance as well as the magnitude of erosion-corrosion synergistic interaction is based on the weight loss measurements. Nondestructive characterization of installations elements is in most cases impossible to perform. Also, such a measurement does not include local types of failure or alteration of operating conditions. There is an urge to elaborate a method for monitoring...
-
Nonlinear impedance in oxide glasses containing single and mixed alkali ions
PublicationThe aim of the present was to find more clues on the nonlinearities in impedance of oxide glasses. The first family of researched glasses has a composition of FeO-P2O5-Na2O. Oxide glasses containing iron and alkali are well known for a very low alkali ion mobility and may be considered purely polaron conducting. These glasses show no detectable nonlinearities in the impedance spectra. The second was a family of ionic conducting...
-
An integral-differential method for impedance determination of the hydrogen oxidation process in the presence of carbon monoxide in the proton exchange membrane fuel cell
PublicationThe impedance of a proton exchange membrane fuel cell powered by hydrogen contaminated with carbon monoxide, ranging from 150 to 300 ppb, is measured and discussed. The tested range of CO concentration complied with the fuel standard specified in the ISO standards. Studies of influence of CO contamination on operation of PEMFC are crucial for further development and commercialization of fuel cells for automotive applications. Based...
-
Nonlinear Impedance as Possible Result of Ion-Polaron Interaction in Cu2O-Al2O3-SiO2 Glass
PublicationNonlinear a.c. impedance measurements were performed in Cu2O-Al2O3-SiO2 glass in wide frequency range. The obtained results shows that a large nonlinearity in the impedance signal is observed at moderate electric fields of an order 1V/mm. The contents of the third harmonics reaches about 10% and strongly depends on temperature and frequency. The investigated glass exhibits mixed electronic-ionic conductivity. Electronic conduction...
-
Impedance evaluation of coatings from biobased material
PublicationThe authors propose a modification of sodium caseinate edible coating for foodstuff protection. The aim was to improve the film’s barrier properties. It was achieved by the addition of propolis, which is a natural, environmentally friendly product known from its intrinsic sealing action. In the next step, propolis-admixed sodium caseinate films were exposed to elevated temperature for 10 min. This approach was meant to improve...
-
Electrical and mechanical characterization of two-phase alloys by means of scanning probe microscopy in dynamic impedance spectroscopy mode
PublicationDynamic impedance spectroscopy, evaluated for measuring non-stationary systems, was used in combination with scanning probe microscope. Using this approach, localized impedance measurements in the AFM contact mode could be carried out. Additionally, impedance–force curves were made at each phase of investigated materials to illustrate the relation between impedance and the force applied to a probe. Therefore, correlation of electrical...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublicationThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Time evolution of Electrochemical Impedance spectra of cathodically protected steel in artificial seawater
PublicationUsability of Electrochemical Impedance Spectroscopy data for better cathodic protection control was investigated. Carbon steel – S235JR2 grade specimen were exposed in artificial seawater environment. Samples were polarized and their potentials corresponded to four different cathodic protection degrees. Time evolution of Electrochemical Impedance spectra was investigated. Goodness of fit function (X2) was analysed in terms of proper...
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublicationThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
PublicationLocal impedance imaging (LII) was used to visualise surficial deviations of AC impedances in polycrystalline boron-doped diamond (BDD). The BDD thin film electrodes were deposited onto the highly doped silicon substrates via microwave plasma-enhanced CVD. The studied boron dopant concentrations, controlled by the [B]/[C] ratio in plasma, ranged from 1 × 1016 to 2 × 1021 atoms cm−3. The BDD films displayed microcrystalline structure,...