Filters
total: 1483
filtered: 1242
displaying 1000 best results Help
Search results for: OPTICAL FIBER INTERFEROMETER
-
Fiber-optic sensors based on microspheres with nanocoatings (Zastosowanie mikrosfer optycznych z cienkowarstwowymi pokryciami w czujnikach światłowodowych)
PublicationTemperature is one of the most important physical quantities. Temperature measurements are used in every field of life, especially electronics, electrical engineering, energy-related fields, including energy source and storage devices. The goal of this dissertation is to design and optimize the microsphere-based fiber-optic sensors construction for measurement of the sensor surrounding medium temperature, including selection of...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublicationThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...
-
Application of wavelength division multiplexing in sensor networks
PublicationOver the past few years the need to acquire data on various parameters from a number of sensors grew. The need that led to the development of a network of sensors which enables simultaneous control and measurement in a wide range of applications. The aim of this article is to discuss a possibility of connecting a variety of sensors in a network that would utilize WDM technology. Wavelength Division Multiplexing is commonly used...
-
Application of thin diamond films in low-coherence fiber-optic Fabry Pérot displacement sensor
PublicationThe novel fiber-optic low coherence sensor with thin diamond films is demonstrated. The undoped and boron-doped diamond films were elaborated by the use of the microwave plasma enhanced chemical vapor deposition (μPE CVD) system. The optical signal from the Fabry–Pérot cavity made with the application of those thin films is sensitive to displacement. The sensor characterization was made in the range of 0–600 μm. The measurements...
-
Investigation of H2:CH4 plasma composition by means of spatially resolved optical spectroscopy
PublicationThe system based on spatially resolved optical emission spectroscopy dedicated for in situ diagnostics of plasma assisted CVD processes is presented in this paper. Measurement system coupled with chemical vapour deposition chamber by dedicated fiber-optic paths enables investigation of spatial distribution of species densities (Hx, H+, CH, CH+) during chemical vapour deposition process. Experiments were performed for a various...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublicationThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Simultaneous optical and electrochemical label-free biosensing with ITO-coated lossy-mode resonance sensor
PublicationIn this work we discuss a new label-free biosensing device based on indium tin oxide (ITO) overlaid section of a multimode optical fiber fused silica core. The sensor has been used to optical measurements also simultaneously interrogated electrochemically (EC). Due to optimized thickness and optical properties of ITO film, a lossy-mode resonance (LMR) could be observed in the optical domain, where electrical properties of the film...
-
Computer support of analysis optical spectra measurements
PublicationVerification of measurement errors has a big impact on assessment of accuracy of conducted measurements and obtained results. In many cases computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with Fabry-Perot interferometer working in the transmission mode. In measurement setup, a 1310 nm superluminescent...
-
Low-coherence photonic method of electrochemical processes monitoring
PublicationWe present an advanced multimodality characterization platform for simultaneous optical and electrochemical measurements of ferrocyanides. Specifcally, we combined a fber-optic Fabry– Perot interferometer with a three-electrode electrochemical setup to demonstrate a proof-ofprinciple of this hybrid characterization approach, and obtained feasibility data in its monitoring of electrochemical reactions in a boron-doped diamond flm...
-
Experimental Testbed of ASON/GMPLS architecture
PublicationThe paper presents the ASON/GMPLS architecture realized in the Department of Teleinformation Networks at Gdansk University of Technology based on the FSP 3000R7 ADVA Optical Networking platform. The FSP 3000R7 is a high-performance WDM networking system with GMPLS control plane for bidirectional transmission of optical signals. The system uses a modular structure which enables a flexible upgrade of capacity and functionality. The...
-
Cost-Efficient Optical Fronthaul Architectures for 5G and Future 6G Networks
PublicationFifth-generation and Beyond (5GB) wireless networks have introduced new centralized architectures such as cloud radio access network (CRAN), which necessitate extremely high-capacity low latency Fronthaul (FH). CRAN has many advantageous features in terms of cost reduction, performance enhancement, ease of deployment, and centralization of network management. Nevertheless, designing and deploying a cost-efficient FH is still a...
-
Low-coherence sensors with nanolayers for biomedical sensing
PublicationIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
Impact of temperature on optical sensing in biology based on investigation of SARS‐CoV ‐2
PublicationIn this paper, we present an investigation of the influence of the temperature on the sensing of biological samples. We used biofunctionalized microsphere-based fiber-optic sensor to detect immunoglobulin G attached to the sensor head at temperatures relevant in biological research: 5°C, 25°C, and 55°C. The construction of the sensor allowed us to perform measurements in the small amount of solution. The results of our experiment...
-
Investigation of photothermolysis therapy of human skin diseases using optical phantoms
PublicationDermatological diseases, such as neurofibroma (Recklinghausen disease) or hemangiomas can be efficiently treated using photothermolysis from laser irradiation. We have utilized a developed 975 nm fiber diode laser as a low-cost alternative over common Nd:YAG lasers. This paper describes the investigations of interaction of 975 nm diode laser radiation-pulses with optical skin phantoms which were designed and manufactured in our...
-
Nanocrystalline diamond microelectrode on fused silica optical fibers for electrochemical and optical sensing
PublicationFabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrode on fused silica single mode optical fiber has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ºC. We have obtained homogenous, continuous and polycrystalline surface morphology with the mean grain size in the range of 100-250...
-
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublicationDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
Tuning of the finesse coefficient of optoelectronic devices
PublicationOptoelectronic devices attracted considerable attention in many branches of science and technology, which can be attributed to their unique properties. Many of them use optical cavities which parameters can be adopted to specific requirements. This thesis investigates the introduction of diamond structures (nitrogen-doped diamond film, boron-doped diamond film, undoped diamond sheet) to optical cavities to tune their finesse coefficient....
-
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
PublicationA unique highly sensitive photonic crystal fiber is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained...
-
Low-coherence method of hematocrit measurement
PublicationDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
Application of the laser diode with central wavelength 975 nm for the therapy of neurofibroma and hemangiomas
PublicationThis paper presents newly developed dermatological laser (with central wavelength 975 nm) for application in therapies requiring deep penetration of tissue, e.g. cutaneous (dermal) neurofibroma (Recklinghausen disease) and hemangiomas. This laser can work either in pulse or continues wave mode. Laser radiation is transmitted toward the application region by optical fiber with a diameter of 0.6 mm. The compact design of the laser...
-
Microsphere structure application for supercapacitor in situ temperature monitoring
PublicationConstant, real-time temperature monitoring of the supercapacitors for efficient energy usage is in high demand and seems to be crucial for further development of those elements. A fiber-optic sensor can be an effective optoelectronic device dedicated for in-situ temperature monitoring of supercapacitors. In this work, the application of the fiber-optic microstrucutre with thin zinc oxide (ZnO) coating fabricated in the atomic layer...
-
Compressible gas density measurement by means of Fourier analysis of interferograms
PublicationThis paper describes a method for nonintrusive compressible gas density measurement by means of automated analysis of interferograms using FFT (Fast Fourier Transform), and its implementation using DFT (Discrete Fourier Transform), that does make this measurement technique a fairly valuable and accessible experimental method. The presented approach makes it possible to use the finite fringe setting of the interferometer, thus reducing...
-
Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film
PublicationThe fabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrodes on fused silica single mode optical fiber cladding has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ºC. We have obtained homogenous, continuous and polycrystalline surface morphology with high sp3 content in B-NCD...
-
Review of the Usefulness of Various Rotational Seismometers with Laboratory Results of Fibre-Optic Ones Tested for Engineering Applications
PublicationStarting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review...
-
Functional fluorine-doped tin oxide coating for opto-electrochemical label-free biosensors
PublicationSensors operating in multiple domains, such as optical and electrochemical, offer properties making biosensing more effective than those working in a single domain. To combine such domains in one sensing device, materials offering a certain set of properties are required. Fluorine-doped tin oxide (FTO) thin film is discussed in this work as functional optically for guiding lossy modes and simultaneously electrochemically, i.e....
-
Enhancing Resilience of FSO Networks to Adverse Weather Conditions
PublicationOptical wireless networks realized by means of gigabit optical wireless communication (OWC) systems are becoming, in a variety of applications, an important alternative, or a complementary solution, to their fiber-based counterparts. However, performance of the OWC systems can be considerably degraded in periods of unfavorable weather conditions, such as heavy fog, which temporarily reduce the effective capacity of the network....
-
Two-photon microperimetry with picosecond pulses
PublicationTwo-photon vision is a phenomenon associated with the perception of short pulsesof near-infrared radiation (900-1200 nm) as a visible light. It is caused by the nonlinear processof two-photon absorption by visual pigments. Here we present results showing the influence ofpulse duration and repetition rate of short pulsed lasers on the visual threshold. We comparedtwo-photon sensitivity maps of the retina obtained for subjects with...
-
Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization
PublicationThe number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its...
-
Reliability and Validity of Optoelectronic Method for Biophotonical Measurements
PublicationReliability and validity of measurements is of utmost importance when assessing measuring capability of instruments developed for research. In order to perform an experiment which is legitimate, used instruments must be both reliable and valid. Reliability estimates the degree of precision of measurement, the extent to which a measurement is internally consistent. Validity is the usefulness of an instrument to perform accurate...
-
Bioactive and biodegradable cotton fabrics produced via synergic effect of plant extracts and essential oils in chitosan coating system
PublicationFunctional antibacterial textile materials are in great demand in the medical sector. In this paper, we propose a facile, eco-friendly approach to the design of antibacterial biodegradable cotton fabrics. Cotton fiber fabrics were enhanced with a chitosan coating loaded with plant extracts and essential oils. We employed Fourier-transform infrared (FTIR) and X-ray photoelectron spectroscopy (XPS), UV–Vis spectrophotometry, optical...
-
Sensitive Demonstration of the Twin-Core Couplers including Kerr Law Non-Linearity via Beta Derivative Evolution
PublicationTo obtain new solitary wave solutions for non-linear directional couplers using optical meta-materials, a new extended direct algebraic technique (EDAT) is used. This model investigates solitary wave propagation inside a fiber. As a result, twin couplers are the subject of this study. Kerr law is the sort of non-linearity addressed there. Because it offers solutions to problems with large tails or infinite fluctuations, the resulting...
-
Investigation into MPI All-Reduce Performance in a Distributed Cluster with Consideration of Imbalanced Process Arrival Patterns
PublicationThe paper presents an evaluation of all-reduce collective MPI algorithms for an environment based on a geographically-distributed compute cluster. The testbed was split into two sites: CI TASK in Gdansk University of Technology and ICM in University of Warsaw, located about 300 km from each other, both connected by a fast optical fiber Ethernet-based 100 Gbps network (900 km part of the PIONIER backbone). Each site hosted a set...
-
Polarization interferometer using a Liquid Crystalline Polymer waveplate for wavelength measurement
PublicationA two-beam polarization interferometer for measuring wavelength changes of a tunable semiconductor laser was designed, built and tested. This interferometer uses a λ/8 waveplate made from Liquid Crystalline Polymer in order to generate two output signals in quadrature. The λ/8 waveplate can be manufactured either on a beamsplitter face or on the mirror surface, reducing the cost and complexity of the optomechnical assembly. Experiment...
-
The use of low-coherence interferometer for sugar content determination
PublicationIn this article, the implementation of low-coherence interferometer with signal processing in time domain for sugar content determination in aqueous solution is presented. The elaborated measurement set-up was tested with the use of synthesized source made of two low-coherence sources. The use of two sources with dedicated parameters enabled to obtain a proper metrological parameters of the measurement system. The elaborated low-coherence...
-
Nanolayers in Fiber-Optic Biosensing
PublicationIn this chapter, fiber-optic sensors based on nanolayers or thin films and their ability to perform biophotonic measurements is presented. In the last decade, fiber-optic sensors have gained popularity as biosensing devices. This has been made possible because of the design and the integration of new materials in fiber-optic technology. Nanolayers and thin films made from various materials such as nanodiamond (NCD), boron-doped...
-
Nitrogen-doped diamond thin films: potential application in Fabry-Pérot interferometer
PublicationIn this paper we present results of preliminary research of using nitrogen-doped diamond (NDD) films as reflective layer in Fabry-Pérot interferometer. NDD films were deposited on Si substrates by Microwave Plasma Enhanced Chemical Vapor Deposition (MPECVD) with the use of CH4, H2 and N2 gas mixtures. During deposition process methane flow rate varied while nitrogen flow was constant. We performed series of measurements which showed...
-
Practical issues for the implementation of survivability and recovery techniques in optical networks
PublicationFailures in optical networks are inevitable. They may occur during work being done for the maintenance of other infrastructures, or on a larger scale as the result of an attack or large-scale disaster. As a result, service availability, an important aspect of Quality of Service (QoS), is often degraded. Appropriate fault recovery techniques are thus crucial to meet the requirements set by the Service Level Agreements (SLAs) between...
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublicationExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...
-
Disaster Resilience of Optical Networks: State of the Art, Challenges, and Opportunities
PublicationFor several decades, optical networks, due to their high capacity and long-distance transmission range, have been used as the major communication technology to serve network traffic, especially in the core and metro segments of communication networks. Unfortunately, our society has often experienced how the correct functioning of these critical infrastructures can be substantially hindered by massive failures triggered by natural...
-
Investigations of the optical activity of nonlinear crystals by means of dual-wavelength polarimeter
PublicationA dual-wavelength method in high accuracy polarimetry has been successfully tested and applied to measure optical activity (OA) of nonlinear crystals. In proposed polarimetric scheme two neighboring semiconductor laser wavelengths (635 and 650 nm) are used, which increases number of parameters measured simultaneously and improves the data processing. By neglecting dispersion of eigen wave ellipticity in crystals, more efficient...
-
Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples
PublicationThe aim of the study was to develop an automated computer-aided system for analysis of spectrograms obtained from measurements of biological samples performed with a low-coherence Fabry-Pérot interferometer. Information necessary to determine dispersion characteristics of measured materials can be calculated from the positions of the maxima and minima that are present in their spectra. The main challenge faced during the development...
-
Characterization of Highly Filled Glass Fiber/Carbon Fiber Polyurethane Composites with the Addition of Bio-Polyol Obtained through Biomass Liquefaction
PublicationThis work aims to investigate the process of obtaining highly filled glass and carbon fiber composites. Composites were manufactured using previously obtained cellulose derived polyol, polymeric methylene diphenyl diisocyanate (pMDI). As a catalyst, dibutyltin dilaurate 95% and Dabco® 33-LV were used. It was found that the addition of carbon and glass fibers into the polymer matrix causes an increase in the mechanical properties...
-
Badawczo-rozwojowe laboratorium sieci optycznych wykorzystujące sprzęt ADVA Optical Networking
PublicationPrzedstawiono uwarunkowania i kierunki zmian w sieciach optycznych, a następnie wskazano na potrzebę posiadania laboratorium, w którym możliwe byłoby prowadzenie prac badawczo-rozwojowych oraz kształcenie. Przedstawiono koncepcję takiej sieci opartej na sprzęcie ADVA Optical Networking zrealizowaną w Katedrze Sieci Teleinformacyjnych Wydziału ETI PG. Opisano możliwości sprzętowo-funkcjonalne tego laboratorium oraz prowadzone prace...
-
Concentrations of heavy metals and PCBs in the tissues of European beavers (Castor fiber) captured in northeastern Poland
PublicationEuropean beavers (Castor fiber) from two regions were examined to identify exposure to persistent environmental contaminants. A reference group was comprised of six animals from the Forest Division of Srokowo, and an exposed group was comprised of five animals from the vicinity of a former military airport operated in 1918–1986—both from Warmia land in Poland. 137 Cs in beavers' muscles was considered negligible for the overall...
-
Optical and electrical properties of ultrathin transparent nanocrystalline boron-doped diamond electrodes
PublicationThe optical properties of ultrathin (less than 100 nm) boron-doped nanocrystalline diamond (B-NCD) film were investigated in a wavelength range of 200 ÷ 20000 nm. The B-NCD refractive index showed values close to that of monocrystalline diamond (n = 2.45) in a broad wavelength range (450 ÷ 4000 nm). A transmittance up to 70% and the average film thickness of 70 nm were achieved. A special cone-shaped shim was used in the deposition...
-
Temperature Fiber-Optic Sensor with ZnO ALD Coating
PublicationThis study presents a microsphere-based fiber-optic sensor with a ZnO Atomic Layer Deposition (ALD) coating thickness of 100 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range of 100 °C to 300 °C, with a 10 °C step. An interferometric signal is used to control whether the microstructure is whole. Spectrum shift of a reflected signal is used to ascertain changes in...
-
Linking optical and electronic properties to photoresponse of heterojunctions based on titania nanotubes and chromium, molybdenum, and tungsten oxides
PublicationThe development of photosensitization strategies for titanium dioxide is necessary for the enhancement of its optical and electronic properties towards its application potential in solar photoelectrochemistry. In this work, significant differences in the photosensitizing capability of the 6th group transition metal oxides applied on the surface of titania nanotubes are reported. For the first time, correlations between the experimentally...
-
Topological extraordinary optical transmission
PublicationΤhe incumbent technology for bringing light to the nanoscale, the near-field scanning optical microscope, has notoriously small throughput efficiencies of the order of 10^4-10^5 or less. We report on a broadband, topological, unidirectionally guiding structure, not requiring adiabatic tapering and, in principle, enabling near-perfect (∼100%) optical transmission through an unstructured single arbitrarily subdiffraction slit at...
-
Nanocrystalline CVD Diamond Coatings on Fused Silica Optical Fibres: Optical Properties Study
Publicationpre-treatment by dip coating in two detonation nanodiamond (DND) seeding media has been studied. The DND suspension in ethyl alcohol and dispersion of DND in dimethyl sulfoxide (DMSO) with polyvinyl alcohol (PVA) were chosen for the seeding purpose. The grain size distribution of nanodiamond particles in both seeding media was kept at the same level (approximately 1050 nm). After the seeding nanocrystalline diamond lms were deposited...
-
Direct shear stress vs strain relation for fiber reinforced composites
PublicationThe majority of fiber reinforced composites exhibit strong non-linear behavior in in-plane shear state. The effect is attributed to the micro-cracks appearing in the matrix and can be modeled on the micro and macro level. In this work the author proposes constitutive laws describing the non-linear in-plane shear response, which can be alternative for the relations commonly considered in the literature. The proposed equations are...