Search results for: INTERFEROMETRIA%20POLARYZACYJNA
-
Paweł Wierzba dr hab. inż.
PeopleDr Paweł Wierzba, E.E. M.Sc. E.E. received from WETI PG 1994 PhD in optoelectronics (with honours) from WETI PG 2001 Research Stays at VTT Technical Research Centre of Finland from 1997 to 2000 Finnish Academy Scholarship at VTT Technical Research Centre of Finland (12 months) 2002-3 Research interest area covers optical and optical fiber meaurement methods, technology of selected ceramic and liquid crystalline materials relevant...
-
INVESTIGATION INTO INTERFEROMETRIC SONAR SYSTEM ACCURACY
PublicationThe results of the accuracy measurements of phase differencing bathymetric sonar (PDBS) system in shallow waters are presented in the article. The measurement results were compared with the theoretical calculations for sonar system accuracy and international standards for hydrographic surveys. The proposed formulas enable to assess a priori sonar system performance using system quality factor (SQF), which takes into account influence...
-
Low-Coherence Fibre-Optic Interferometric Sensors
Publication -
Low-coherence Fiber-Optic Interferometric Sensors
PublicationW artykule porównano parametry metrologiczne zrealizowanych niskokoherencyjnych czujników światłowodowych wykorzystujących interferometr Michelsona oraz Fabry-Perot.
-
Coupledfield modelling of interferometric hydrophone with self supportedmandrel.
PublicationW pracy przedstawiono nowatorską konstrukcję światłowodowego interferometrycznego przetwornika ciśnienia do zastosowań w hydrofonach. Przetwornik ten składa się z cewki światłowodowej zalanej w żywicy epoksydowej. Zaprezentowano technikę modelowania właściwości przetwornika, wykorzystującą opis przy pomocy parametrów równoważnego materiału ortotropowego i Metodę Elementów Skończonych. Przestawiono wyniki statycznego modelowania...
-
Applications of polarization interferometry in optical sensors
PublicationW artykule przedstawiono wybrane realizacje interferometrycznych czujników przesunięcia, wykonanych z elementów optyki objętościowej. Czujniki te, stosowane w technice pomiarowej i mikroskopii, charakteryzują się dużą rozdzielczością i dokładnością pomiaru. Omówiono problemy związane z implementacją tych czujników, wpływające na pogorszenie dokładności pomiaru. Zaprezentowano metody korekcji sygnału wyjściowego, opracowane dla...
-
Direction-of-Arrival Estimation Methods in Interferometric Echo Sounding
PublicationNowadays, there are two leading sea sounding technologies: the multibeam echo sounder and the multiphase echo sounder (also known as phase-dierence side scan sonar or bathymetric side scan sonar). Both solutions have their advantages and disadvantages, and they can be perceived as complementary to each other. The article reviews the development of interferometric echo sounding array configurations and the various methods applied...
-
White-light interferometric temperature sensor for biomedical diagnostic.
PublicationW artykule opisano opracowany model miniaturowego, światłowodowego czujnika temperatury z interferometrem Fabry-Perot wykorzystującego interferencję światła białego przeznaczonego do zastosowań biomedycznych. Analizowano czujnik wykonany ze światłowodu wielomodowego o skokowym profilu współczynnika załamania oraz ze światłowodu monomodowego. Zasadniczym celem był dobór parametrów mający na celu uzyskania maksymalnej widzialności...
-
Accuracy improvement of bulk optical polarization interferometric sensors
PublicationW artykule przedstawiono optyczne czujniki wykorzystujące interferometrię polaryzacyjną. Omówiono czynniki obniżające ich dokładność pomiaru. Zaprezentowano metodę obróbki sygnału,która umożliwia częściową eliminację wpływu tych czynników i nową implementację tej metody, wykorzystującą układ analogowy o znacznie zmniejszonej nieliniowości.
-
Zastosowanie interferometrów światła białego w metrologii
PublicationW artykule omówiono zasadę działania i właściwości interferometrów światła białego z przetwarzaniem w dziedzinie fazy. Przedstawiono metody identyfikacji centralnego prążka w interferogramie. Przeprowadzono optymalizację doboru parametrów źródeł światła ze względu na minimalną wymaganą wartość stosunku sygnału do szumu dla poprawnej identyfikacji centralnego prążka w interferogramie.
-
Comprehensive modeling of interferometric hydrophone with self-supported mandrel transducer.
PublicationW pracy przedstawiono wyniki modelowania nowego typu samonośnego przetwornika dla interferometrycznego hydrofonu światłowodowego. Zaprezentowano wyniki analizy statycznej, modowej i dynamicznej przeprowadzonej przy pomocy Metody Elementów Skończonych. W modelowaniu wykorzyastano techniki opracowane dla laminatów, co pozwoliło na uzyskanie dokładnych wyników przy względnie krótkim czasie obliczeń.
-
Swapping Space for Time: An Alternative to Time-Domain Interferometry
PublicationYoung's double-slit experiment [1] requires two waves produced simultaneously at two different points in space. In quantum mechanics the waves correspond to a single quantum object, even as complex as a big molecule. An interference is present as long as one cannot tell for sure which slit is chosen by the object. The more we know about the path, the worse the interference. In the paper we show that quantum mechanics allows for...
-
Optical low-coherence interferometry for selected technical applications
PublicationW artykule przedstawiono teoretyczne podstawy optycznej interferometrii niskokoherentnej i przedyskutowano jej unikatowe właściwości. Opisano w nim opracowany przez autorów system OCT przeznaczony do badań strukturalnych materiałów technicznych. Badania te obejmują także zmiany stanu polaryzacji promieniowania rozproszonego w badanym obiekcie. W artykule zawarto wyniki badań wybranych materiałów silnie rozpraszających promieniowanie...
-
General concept of reduction process for big data obtained by interferometric methods
PublicationInterferometric sonar systems apply the phase content of the sonar signal to measure the angle of a wave front returned from the seafloor or from a target. It collect a big data – datasets that are so large or complex that traditional data processing application software is inadequate to deal with them. The recording a large number of data is associated with the difficulty of their efficient use. So data have to be reduced. The main...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
<title>White-light interferometric temperature sensor for biomedical diagnostic</title>
Publication -
Wybrane realizacje układów detekcji czujników optycznych wykorzystujących interferometrię polaryzacyjną
PublicationW artykule przedstawiono wymagania stawiane układom detekcji czujników optycznych wykorzystujących interferometrię polaryzacyjną. Zaprezentowano stosowane rozwiązania tych układów i omówiono możliwości ich modyfikacji poprzez zastosowanie elementów optycznych wykonanych zciekłych kryształów i polimerów ciekłokrystalicznych. Przedstawiono wybrane realizacje układów detekcji i omówiono wpływ szumów części elektronicznej układów na...
-
Badanie niejednorodności warstwy ceramiki PLZT metodami optycznej interferometrii niskokoherentnej
PublicationW artykule omówiono metodę badania wewnętrznej struktury materiałów ceramicznych z wykorzystaniem interferometrii niskokoherentnej. Przedstawiono układ pomiarowy optycznej tomografii koherentnej, wykorzystujący niskokoherentny interferometr do badania niejednorodności występujących w strukturze ośrodków rozpraszających. Zaprezentowano wyniki pomiarów grubości i niejednorodności ceramicznych warstw PLZT. Przeprowadzono rozważania...
-
Badanie niejednorodności warstwy ceramiki PLZT metodami optycznej interferometrii niskokoherentnej
PublicationW artykule omówiono metodę badania wewnętrznej struktury materiałów ceramicznych z wykorzystaniem interferometrii niskokoherentnej. Przedstawiono układ pomiarowy optycznej tomografii koherentnej, wykorzystujący niskokoherentny interferometr do badania niejednorodności występujących w strukturze ośrodków rozpraszających. Zaprezentowano wyniki pomiarów grubości i niejednorodności ceramicznych warstw PLZT. Przeprowadzono rozważania...
-
Selection of SOM parameters for the needs of clusterization of data obtained by interferometric methods
Publication -
Interferometric Sensor of Wavelength Detuning Using a Liquid Crystalline Polymer Waveplate
PublicationOperation of a polarization interferometer for measurement of the wavelength changes of a tunable semiconductor laser was investigated. A lambda/8 waveplate made from liquid crystalline polymer is placed in one of interferometers’ arms in order to generate two output signals in quadrature. Wavelength was measured with resolution of 2 pm in the wavelength range 628–635 nm. Drift of the interferometer, measured in the period of 500...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Fiber-optic temperature sensor using low-coherence interferometry
Publication -
Measuring the density of DNA films using ultraviolet-visible interferometry
PublicationIn order to determine a proper value for the density of dry DNA films we have used a method based upon the measurement of interference effects in transmission spectra of thin DNA layers. Our results show that the methodology is effective and the density of DNA in this state, 1.407 g/cm3, is much lower than the commonly used 1.7 g/cm3. Obtaining accurate values for the DNA film density will allow the optical constants for DNA to...
-
Tunable semiconductor laser application for interferometric optical fibersensors.Optical and Electronic Sensors V.
PublicationW pracy przedstawiono metody stabilizacji punktu pracy światłowodowych sensorów interferometrycznych. W metodach tych wykorzystuje się układy regulacji sterujące długością fali przestrajalnego lasera półprzewodnikowego. Przedstawiono tryby pracy układów regulacji oraz problemy związane z ich projektowaniem i realizacją. Przeanalizowano ograniczenia sensorów wykorzystujących powyższe układy. Dokonano weryfikacji eksperymentalnej...
-
Optimization of white light interferometric temperature sensor. Workshop on Atomic and Molecular Physics.
PublicationW artykule przedstawiono metodę optymalizacji parametrów niskokoherencyjnego interferometrycznego czujnika temperatury wykorzystującego miniaturowy interferometr Farby Perota, pracujący w modzie odbiciowym.
-
Wpływ doboru parametrów źródła na rozdzielczość pomiaru w interferometrii niskokoherencyjnej.
PublicationJednym z podstawowych elementów niskokoherencyjnego, interferometrycznego systemu pomiarowego jest szerokopasmowe źródło światła. Wybór źródła jest bardzo ważny, gdyż jego parametry mają bezpośredni wpływ na końcową jakość pomiaru. Z tego też względu wydaje się niezbędnym poznanie charakterystyk źródeł szerokopasmowych wykorzystywanych w interferometrii niskokoherencyjnej i zależności, pomiędzy parametrami źródła, a jakością pomiaru.
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublicationIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Modeling of selected transducer designs for optical pressure sensors using polarization interferometry
PublicationW artykule przedstawiono wyniki modelowania metodą Elementów Skończonych wybranych konstrukcji membran do zastosowań w interferometrycznych czujnikach ciśnienia. Omówiono zależność prametrów membran od kształtu membrany, jej wymiarów i zastosowanego materiału. Zakres odkształcen badanych membran jest niezbyt duży, co może pogarszać dokładność pomiaru czujników ciśnienia, w których będą one stosowane Omówiono kierunki dalszych...
-
Miniaturowy czujnik temperatury z interferometrem światła białego dla zastosowań biomedycznych.
PublicationW artykule opisano model miniaturowego, światłowodowego czujnika temperatury z interferometrem Fabry Perota wykorzystującego interferencję światła białego, dla zastosowań biomedycznych.
-
Zastosowanie interferometrii niskokoherentnej do jednoczesnego pomiaru grubości i współczynnika załamania struktur warstwowych
PublicationW pracy przedstawiono techniki oparte na interferometrii niskokoherentnej jednoczesnego pomiaru współczynnika załamania i grubości struktur warstwowych. Zaproponowano dwie metody: pierwsza oparta jest na pomiarze położenia górnej powierzchni granicznej warstwy i jej grubości optycznej (położenie dolnej powierzchni granicznej powinno być znane wcześniej); druga oparta jest na wykorzystaniu dynamicznego ogniskowania wiązki laserowej....
-
Metody matematyczne syntezowania źródeł optycznych do interferometrów niskokoherentnych dla zastosowa biomedycznych
PublicationW pracy przedstawiono mozliwosci wykorzystania metod matematycznych w układach interferometrii niskokoherentnej do zastosowan biomedycznych. Metody takie sa wykorzystywane na kazdym z etapów realizacji układów: projektowania poszczególnych elementów, obróbki danych pomiarowych oraz w trakcie walidacji techniki pomiarowej. W pracy przedstawiono mozliwosci optymalizacji parametrów metrologicznych interferometrów niskokoherentnych...
-
Comparison of selected clustering algorithms of raw data obtained by interferometric methods using artificial neural networks
Publication -
Coda wave interferometry in monitoring the fracture process of concrete beams under bending test
PublicationEarly detection of damage is necessary for the safe and reliable use of civil engineering structures made of concrete. Recently, the identification of micro-cracks in concrete has become an area of growing interest, especially using wave-based techniques. In this paper, a non-destructive testing approach for the characterization of the fracture process was presented. Experimental tests were made on concrete beams subjected to mechanical...
-
Method for the correlation coefficient estimation of the bottom echo signal in the shallow water application using interferometric echo sounder
PublicationThe article presents a new method for the assessment of bottom echo correlation coefficient in the presence of multiple echoes. Bottom correlation coefficient is a parameter that characterizes spatial properties of echo signal. Large variability of the bottom shape or properties (for example caused by the presence of bottom objects) and the presence of the acoustic shadow strongly influence the value of the correlation coefficient....
-
Laser reflectance interferometry system with a 405 nm laser diode for in-situ measurement of CVD diamond thickness
PublicationIn situ monitoring of the thickness of thin diamond films during technological processes is important because it allows better control of deposition time and deeper understanding of deposition kinetics. One of the widely used techniques is laser reflectance interferometry (LRI) which enables non-contact measurement during CVD deposition. The authors have built a novel LRI system with a 405 nm laser diode which achieves better...
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublicationIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Spectral reflectance modeling of ZnO layers made with Atomic Layer Deposition for application in optical fiber Fabry-Perot interferometric sensors
PublicationSuitability of zinc oxide (ZnO) layers grown using Atomic Layer Deposition for operation in optical-fiber extrinsic Fabry-Perot sensors is investigated using a numerical model. Reflectance spectra obtained using the developed model indicate that the application of these layers in optical-fiber extrinsic Fabry-Perot sensors is difficult as it may require a source whose spectrum width is about 300 nm. A series of ZnO layers grown...
-
Interferometric optical fiber sensors with active stabilization of the operating point using a tunable semiconductor laser. Optical Fibres and Their Applications VIII.
PublicationW pracy przedstawiono wyniki badań światłowodowych interferometrycznych sensorów siły wykonanych w konfiguracji interferometru Michelsona i wykorzystujących aktywną stabilizację punktu pracy przy pomocy zmiany długości fali źródła. Porównano dwie klasy omawianych sensorów a następnie zrealizowano sensor. W konstrukcji sensora zastosowano modulator z pośrednim pomiarem siły. Mierzona siła jest zamieniana na ciśnienie hydrostatyczne,...
-
Application of sol-gel-developed integrated optic devices to biochemical fiber optic sensors based on polarimetric interferometry.
PublicationW pracy omówiono zasady działania sensorów optycznych wykonanych w technologii optyki zintegrowanej i wykorzystujących interferometrię polaryzacyjną. Zaproponowano konstrukcję jednorazowego przetwornika pomiarowego, wykonanego w technologii sol-żel z materiałów hybrydowych, która umożliwia wykorzystanie nieodwracalnych reakcji chemicznych do pomiarów w medycynie, chemii i ochronie środowiska. Omówiono technologię syntezy materiałów...
-
In-situ optical diagnostics of boron-doped diamond films growth
PublicationInterferometry is a desirable method for in-situ measurement of thin, dielectric film growth, as it don't modify conditions of film deposition. Here we present interferometrical measurements of thickness of doped diamond films during Chemical Vapor Deposition (CVD) process. For this purpose we used a semiconductor laser with a 405nm wavelength. Additional ex-situ measurement using spectral interferometry and ellipsometry...
-
Crack monitoring in concrete beams under bending using ultrasonic waves and coda wave interferometry: the effect of excitation frequency on coda
PublicationConcrete is one of the most widely used construction materials in the world. In recent years, various non-destructive testing (NDT) and structural health monitoring (SHM) techniques have been investigated to improve the safety and control of the current condition of concrete structures. This study focuses on micro-crack monitoring in concrete beams. The experimental analysis was carried out on concrete elements subjected to three-point...
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublicationThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Modyfikowane nanodiamentowe warstwy do sensorów z detekcją optyczną i elektrochemiczną
PublicationW rozprawie doktorskiej przedstawiono opracowanie parametrów procesów syntezy osadzania z fazy gazowej wspomaganego plazmą mikrofalową (MWPACVD) do wytwarzania warstw nanodiamentowych o niskim współczynniku absorpcji optycznej i wysokiej przewodności elektrycznej. Warstwy te są przeznaczone do sensorów z detekcją optyczną i elektrochemiczną stosowanych w układzie interferometru Mach-Zehndera do badania in situ modyfikacji elektrod...
-
Optical Investigation of Hematocrit Level in Human Blood
PublicationW artykule przedstawiono możliwości wykorzystania metod optoelektronicznych, takich jak: spektroskopia Ramana i interferometria niskokoherencyjna do pomiaru poziomu hematokrytu ludzkiej krwi.
-
Zastosowanie czasowo-częstotliwościowej analizy sygnałów dla poprawy właściwości metrologicznych systemów optycznej tomografii koherentnej
PublicationOptyczna tomografia koherentna (OCT) jest metodą obrazowania wewnętrznej struktury obiektów rozpraszających promieniowanie optyczne. Metoda ta wykorzystuje interferometrię niskokoherentą do pomiaru czasu przelotu promieniowania wstecznie rozproszonego od elementów struktury obrazowanego obiektu z rozdzielczością w zakresie od jednego do kilkunastu mikrometrów. Rozprawa dotyczy dwóch rozszerzeń metody OCT. Pierwsze z nich – polaryzacyjna...
-
Badania naprężeń własnych laserowo przetapianej stali X20Cr13 pod wpływem kawitacji.
PublicationPraca prezentuje badania wpływu obciążeń kawitacyjnych przetapianej laserowo stali X20Cr13 na wielkość naprężeń własnych. Do wyznaczania wielkości naprężeń własnych zastosowano metodę zautomatyzowanej interferometrii siatkowej.
-
Stability of an optical displacement sensor using a two-beam polarization interferometer
PublicationW artykule przedstawiono wyniki pomiarów stabilności wybranej konfiguracji dwuwiązkowego interferometru polaryzacyjnego. Przedyskutowano źródła występującej niestabilności.
-
Low-coherence method of hematocrit measurement
PublicationDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
Postępy w badaniach korelacji pomiędzy morfologią i właściwościami segmentowych poliuretanów.
PublicationW pracy opisano postępy w badaniach mikroskopowych poliuretanów segmentowych. Przedmiotem omówienia były mikroskopia optyczna polaryzacyjna, mikroskopia optyczna konfokalna, mikroskopia elektronowa, mikroskopia sił atomowych oraz połączone badania mikroskopowe z innymi metodami (spektometria mikroramanowska, mikroskopia termiczna). Za pomocą tych metod zinterpretowano morfologie poliestrouretanów otrzymywanych w technologii reaktywnego...