displaying 1000 best results Help
Search results for: SWITCHED-BEAM ANTENNA, ELECTRONICALLY STEERABLE PARASITIC ARRAY RADIATOR (ESPAR) ANTENNA, DIRECTION-OF-ARRIVAL (DOA), RECEIVED SIGNAL STRENGTH (RSS), WIRELESS SENSOR NETWORK (WSN)
-
An Empirical System Loss Model for Body Area Networks in a Passenger Ferry Environment
PublicationThis paper presents a general empirical system loss model for estimating propagation loss in Body Area Networks in off-body communications at 2.45 GHz in a passenger ferry environment. The model is based on measurements, which were carried out in dynamic scenarios in the discotheque passenger ferry environment. The model consists of three components: mean system loss, attenuation resulting from the variable antenna position on...
-
An Empirical System Loss Model for Body Area Networks in a Passenger Ferry Environment
PublicationThis paper presents a general empirical system loss model for estimating propagation loss in Body Area Networks in off-body communications at 2.45 GHz in a passenger ferry environment. The model is based on measurements, which were carried out in dynamic scenarios in the discotheque passenger ferry environment. The model consists of three components: mean system loss, attenuation resulting from the variable antenna position on...
-
Local response surface approximations and variable-fidelity electromagnetic simulations for computationally efficient microwave design optimisation
PublicationIn this study, the authors propose a robust and computationally efficient algorithm for simulation-driven design optimisation of microwave structures. Our technique exploits variable-fidelity electromagnetic models of the structure under consideration. The low-fidelity model is optimised using its local response surface approximation surrogates. The high-fidelity model is refined by space mapping with polynomial interpolation of...
-
A survey on network resiliency methodologies against weather-based disruptions
PublicationDue to the increasing dependence on network services of our society, research has recently been concentrating on enhancing traditional protection strategies to withstand large-scale failures, as in case of disaster events. The recently-formed EU-funded RECODIS project aims at coordinating and fostering research collaboration in Europe on disaster resiliency in communication networks. In particular, the Working Group (WG) 2 of the...
-
Acoustic radar employing particle velocity sensors
PublicationA concept, practical realization and applications of a passive acoustic radar to automatic localization, tracking of sound sources were presented in the paper. The device consist of the new kind of multichannel miniature sound intensity sensors and a group of digital signal processing algorithms. Contrary to active radars, it does not emit the scanning beam but after receiving surroundings sounds it provide information about the...
-
Impact of surface skin temperature change on blood flow characteristics in palm
PublicationHeating a human palm during 3 minutes period causes changes in superficial skin temperature and leads to thermoregulation system response. The response time and level of flow characteristics change depend on the subject hand size and health of his vascular tree. A solution of Pennes bioheat propagation model was analyzed in order to see how much heat has to be transferred into the tissue to extort the observable reaction. The reflective...
-
Analysis of distance measurement errors in CW FM sonar with MLS code modulation
PublicationAlthough used in the classic silent sonar, the CW FM sounding signal has a major flaw which is its inaccuracy in determining the distance to a target. The authors of the article have developed a concept of silent sonar using frequency modulation signals switched by pseudorandom codes, already discussed in their previous work. This article presents a detailed analysis of errors in CW FM sonar with pseudo-random sequence code modulation...
-
Equal Baseline Camera Array—Calibration, Testbed and Applications
PublicationThis paper presents research on 3D scanning by taking advantage of a camera array consisting of up to five adjacent cameras. Such an array makes it possible to make a disparity map with a higher precision than a stereo camera, however it preserves the advantages of a stereo camera such as a possibility to operate in wide range of distances and in highly illuminated areas. In an outdoor environment, the array is a competitive alternative...
-
Acceleration of Electromagnetic Simulations on Reconfigurable FPGA Card
PublicationIn this contribution, the hardware acceleration of electromagnetic simulations on the reconfigurable field-programmable-gate-array (FPGA) card is presented. In the developed implementation of scientific computations, the matrix-assembly phase of the method of moments (MoM) is accelerated on the Xilinx Alveo U200 card. The computational method involves discretization of the frequency-domain mixed potential integral equation using...
-
Analiza wpływu błędu częstotliwości próbkowania na sygnały odbierane w systemie LTE
PublicationW artykule dokonano analizy wpływu błędu częstotliwości próbkowania w platformie radia programowalnego na odbierany sygnał LTE (Long Term Evolution).
-
Deep neural networks for human pose estimation from a very low resolution depth image
PublicationThe work presented in the paper is dedicated to determining and evaluating the most efficient neural network architecture applied as a multiple regression network localizing human body joints in 3D space based on a single low resolution depth image. The main challenge was to deal with a noisy and coarse representation of the human body, as observed by a depth sensor from a large distance, and to achieve high localization precision....
-
Impact of Galileo Observations on the Position and Ambiguities Estimation of GNSS Reference Stations
PublicationDevelopment of Galileo navigation system has caused that it is increasingly used in various areas. One of the most important of them is precise positioning of the reference networks. In this paper we present the impact of Galileo observations on the differential precise positioning as well as ambiguities resolution of selected GNSS stations. We tested five different solutions: GPS-only, Galileo-only, GPS/Galileo, GPS/GLONASS and...
-
Radio Channel Measurements in Off-Body Communications in a Ferry Passenger Cabin
PublicationThis paper presents an off-body radio channel measurements in a ferry passenger cabin at 2.45 GHz band, for static sleeping scenarios with different body orientation and on-body antennas placements, and also for upper and lower sleeping berths. The measurements have been performed with two types of on-body wearable receiving antennas: FlexPIFA (flexible planar inverted F antenna), and FlexNotch (flexible adhesive-backed notch antenna)...
-
Noise effect on parameters of quiet sonar with code modulation
PublicationEarlier publications of the paper authors have shown that the use of code keying mixed with the CW FM sound signal allows the significant reduction in the distance measurement error, compared to classic silent CW FM sonar. In addition to the code modulation parameters, the magnitude of this error is influenced by the received input acoustic noise. The article shows the dependence of the input signal-to-noise ratio and the sound...
-
Electrocatalytic Gas Sensor with Reference Layer
PublicationThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Machine-learning-based precise cost-efficient NO2 sensor calibration by means of time series matching and global data pre-processing
PublicationAir pollution remains a considerable contemporary challenge affecting life quality, the environment, and economic well-being. It encompasses an array of pollutants—gases, particulate matter, biological molecules—emanating from sources such as vehicle emissions, industrial activities, agriculture, and natural occurrences. Nitrogen dioxide (NO2), a harmful gas, is particularly abundant in densely populated urban areas. Given its...
-
Application of thin diamond films in low-coherence fiber-optic Fabry Pérot displacement sensor
PublicationThe novel fiber-optic low coherence sensor with thin diamond films is demonstrated. The undoped and boron-doped diamond films were elaborated by the use of the microwave plasma enhanced chemical vapor deposition (μPE CVD) system. The optical signal from the Fabry–Pérot cavity made with the application of those thin films is sensitive to displacement. The sensor characterization was made in the range of 0–600 μm. The measurements...
-
Measurements of ASON/GMPLS connection control layer performance according to the ETSI methodology
PublicationMeasurements of performance have always been crucial for evaluation of telecommunication systems, especially for implementation of network control elements responsible for connection handling which regards to bandwidth reservation, modification and release. That problem also arises in Automatically Switched Optical Network/Generalized Multiprotocol Label Switching (ASON/GMLPS) architecture, which is considered as one of the components...
-
Embedded system using Bluetooth Low Energy sensors for smart farming applications
PublicationThe main goal of this Bachelor of Engineering project titled Embedded system using Bluetooth Low Energy sensors for smart farming applications is to create a prototype of a system consistent with Agriculture 4.0 concept using Bluetooth Low Energy (BLE) technology. Developed solution shall be easy in implementation and its main functionality shall be periodic gathering of data from environmental sensors...
-
Magnetic field gradient as the most useful signal for detection of flaws using MFL technique
PublicationThe magnetic flux leakage (MFL) technique is extensively used for detection of flaws as well as for evaluation of their dimensions in ferromagnetic materials. However, proper analysis of the MFL signal is hindered by the MFL sensor velocity causing distortions of this signal. Traditionally measured components of the MFL signal are particularly sensitive to the scanning velocity. In this paper, an another signal – the gradient of...
-
Cross-layer integration of network mechanisms for increasing efficiency of multimedia session support in IEEE 802.11s environment
PublicationWith an IEEE 802.11 wireless networks operating in Point-to-Multipoint mode being the most popular WLAN access technology employed today, it can be expected that a Wireless Mesh Network (WMN) based on the technology can provide significant advantages for such network systems. The IEEE 802.11s standard amendment provides the comprehensive set of mechanisms required to implement and deploy a WMN utilizing this widely popular technology....
-
An odor-sensing system - powerful technique for foodstuff studies
PublicationThis work examines gas sensor array technology combined with multivariate data processing methods and demonstrates a promising potential for rapid, non-destructive analysis of food. Main attention is focused on detailed description of sensor used in e-nose instruments, construction, and principle of operation of these systems. Moreover, this paper briefly reviews the progress in the field of artificial olfaction and future trends...
-
Service and Path Discovery Extensions for Self-forming IEEE 802.11s Wireless Mesh Systems
PublicationWith the rapid growth of the quantity and capabilities of end-user electronic devices, both stationary and mobile, they are employed in increasing number of applications. In this situation, wireless network technologies begin to play a crucial role as networks access technologies, as cable-based solutions tend to be of limited utility in case of easily portable or mobile devices. Resulting development of wireless technologies reached...
-
Reliability data safety instrumented systems SIS from the functional safety analysis example critical instalation
Open Research DataThe dataset represents the results of an example of functional safety analysis systems is presented below. It is based on a control system, which consists of some basic components like sensors, programmable logic controllers and valves. It is a part of petrochemical critical installations. The communication between sensor logic controllers and actuators...
-
Sonar Pulse Detection Using Chirp Rate Estimation and CFAR Algorithms
PublicationThis paper presents a new approach to sonar pulse detection. The method uses chirp rate estimators and algorithms for the adaptive threshold, commonly used in radiolocation. The proposed approach allows detection of pulses of unknown parameters, which may be used in passive hydrolocation or jamming detection in underwater communication. Such an analysis is possible thanks to a new kind of imaging, which presents signal energy in...
-
The realization of ASON/GMPLS control plane
PublicationASON (Automatic Switched Optical Network) is a concept of optical network recommended in G.8080/Y.1304 by ITU-T. Control Plane of this network could be based on GMPLS (Generalized Multi-Protocol Label Switching) protocols like RSVP-TE, OSPF-TE, LMP. This solution is named ASON/GMPLS. In this chapter we present the control plane problems and proposes ASON/GMPLS network realization that are tested on testbed consists of three and...
-
Enhancing Resilience of FSO Networks to Adverse Weather Conditions
PublicationOptical wireless networks realized by means of gigabit optical wireless communication (OWC) systems are becoming, in a variety of applications, an important alternative, or a complementary solution, to their fiber-based counterparts. However, performance of the OWC systems can be considerably degraded in periods of unfavorable weather conditions, such as heavy fog, which temporarily reduce the effective capacity of the network....
-
Development of beltless respiration and heartbeat sensor based on flexible piezoelectric film
PublicationThe main goal of this work is to report initial development on a respiration and heartbeat measurement sensor that can be used in continuous monitoring conditions at a minimal impact on the patient. General description of the sensor, consisting of a PVDF film and the bonding layer, is given. Open-circuit voltage generated by the sensor is estimated by analytical and numerical calculations. Analog and digital interface used to extract...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a sea voyage.
-
The vortex flow caused by sound in a bubbly liquid
PublicationGeneration of vorticity in the field of intense sound in a bubbly liquid in the free half-space is considered. The reasons for generation of vorticity are nonlinearity, diffraction, and dispersion. Acoustic streaming differs from that in a Newtonian fluid. Under some conditions, the vortex flow changes its direction. Conclusions concern streaming induced by a harmonic or an impulse Gaussian beam.
-
Data fusion of GPS sensors using Particle Kalman Filter for ship dynamic positioning system
PublicationDepending on standards and class, dynamically positioned ships make use of different numbers of redundant sensors to determine current ship position. The paper presents a multi-sensor data fusion algorithm for the dynamic positioning system which allows it to record the proper signal from a number of sensors (GPS receivers). In the research, the Particle Kalman Filter with data fusion was used to estimate the position of the vessel....
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 130 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 110 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 120 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 75 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 65 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 90 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 80 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 45 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 35 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 50 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 70 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapasitor with the use of ZnO coated microsphere-based fiber-optic sensor - 30 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 60 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 100 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Radio Channel Measurements in Body-to-Body Communications in Different Scenarios
PublicationThis paper presents body-to-body radio channel measurements at the 2.45 GHz band, for different body motion scenarios and on-body antenna placements, and both indoor and outdoor environments. Measurement equipment, investigated scenarios and considered environments are described, an initial analysis of results being presented. The mean path loss and the standard deviation depend on the mutual location of transmitting and receiving...
-
Radio Channel Measurements in Body-to-Body Communications in Different Scenarios
PublicationThis paper presents body-to-body radio channel measurements at the 2.45 GHz band, for different body motion scenarios and on-body antenna placements, and both indoor and outdoor environments. Measurement equipment, investigated scenarios and considered environments are described, an initial analysis of results being presented. The mean path loss and the standard deviation depend on the mutual location of transmitting and receiving...