displaying 1000 best results Help
Search results for: early stage of injection
-
Wilms tumor - Female, 4 - Tissue image [5070730026206891]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 1 - Tissue image [5170730021238781]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [507073002620741]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 1 - Tissue image [5170730021231891]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Do clusters help companies to "go green"? Experience of Polish National Key Clusters
PublicationThis study aims to explore cluster activity in the field of green transformation, taking into account the green, low-carbon and circular economy. Our intention was to identify the main green practices used by cluster organizations, which we showed through the lens of the attributes of both the cluster and the cluster organization. Through our study, we sought to answer the question: what is the role of cluster organizations in...
-
Transformation of polyvinyl chloride (PVC) into a versatile and efficient adsorbent of Cu(II) cations and Cr(VI) anions through hydrothermal treatment and sulfonation
PublicationThe reuse of waste polyvinyl chloride (PVC) has drawn much attention as it can reduce plastic waste and associated pollution, and provide valuable raw materials and products. In this study, sulfonated PVC-derived hydrochar (HS-PVC) was synthesized by two-stage hydrothermal treatment (HT) and sulfonation, and shown to be a versatile adsorbent. The reoval of Cu(II) cations and Cr(VI) anions using HS-PVC reached 81.2 ± 1.6% and 60.3...
-
Deformations of the steel schell of a vertical cylindrical tank caused by underpressure
PublicationUnderpressure in a tank with a fixed roof may arise in the final stage of its construction as well as during its usage. This article presents stages of deformations of the tank shell and their development from the occurrence of the first deformation to either removal of the causes of underpressure or cracking of the steel shell.
-
Characterization of Corrosion-Induced Fracture in Reinforced Concrete Beams Using Electrical Potential, Ultrasound and Low-Frequency Vibration
PublicationThe paper deals with the non-destructive experimental testing of the reinforced concrete beams under progressive corrosion. A series of experiments using electrical potential, ultrasound and low-frequency vibrations techniques are reported. Electrical potential and natural frequencies were used to characterise and monitor the corrosion process at its initial state. The P-wave velocity measurements were proved to be effective in...
-
Observation on red blood cells fluctuations by diffraction phase microscopy
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – Red Blood Cells (RBCs). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations...
-
GaAs ballistic and tunneling nanodevices for terahertz electronics and medical applications
PublicationPrzy użyciu selektywnej epitaksji warstw molekularnych (MLE) wytworzono w GaAs balistyczne i tunelowe tranzystory o indukcji elektrostatycznej (SIT), z kanałami w skali 10 nm. Szacowany czas przelotu elektronów jest krótszy od 2×10-14 s. Metoda MLE została również wykorzystana do wykonania diod generacyjnych TUNNETT działających w oparciu o czas przelotu i tunelowe wstrzykiwanie elektronów. Z użyciem diod TUNNETT wygenerowano częstotliwość...
-
APPLICATION OF THE THEORY OF SEMI-MARKOV PROCESSES TO DETERMINE A LIMITING DISTRIBUTION OF THE PROCESS OF CHANGES OF ABILITY AND INABILITY STATES OF FUEL SUPPLY SYSTEMS IN HEAVY FUEL DIESEL ENGINES
PublicationThe paper presents applicability of the theory of semi-Markov processes to determine a limiting distribution of the process of changes of technical states of fuel systems for marine engines running on heavy fuel oils. The proposed study of this process includes the components of such fuel systems like: 1 - injectors, 2 - high pressure hoses, 3 - injection pumps, 4 - low pressure hoses, 5 – fine filters, 6 - coarse filters, 7 – fuel-feed...
-
THE IDENTIFICATION OF TOXIC COMPOUND EMISSION SENSITIVITY AS A DIAGNOSTIC PARAMETER DURING DYNAMIC PROCESSES OF THE MARINE ENGINE
PublicationChanging some parameters of the engine structure alters the emission of harmful components in the exhaust gas. This applies in particular to the damage of charge exchange system as well as fuel system and engine supercharger. These changes are much greater during the dynamic states and their accompanying transitional processes. The different sensitivity of diagnostic parameters to the same force, coming from the engine structure,...
-
An application of simulation model of fuel consumption in diagnostic system of wheeled tractors
PublicationAn application of computer controlled fuel injection systems in vehicle engines and growing demands concerning toxic substances emission and fuel consumption was a main reason for OBD (On Board Diagnosis) development. In spite of a great technological development, only some tractors are equipped in diagnostic systems. On board diagnostic is strongly connected with emission demands and does not concern other important vehicle functions. In...
-
Fuctional structure of diagnostic system for wheeled tractors
PublicationAn application of computer controlled fuel injection systems in vehicle engines and growing demands concerning toxic substances emission and fuel consumption was a main reason for OBD (On Board Diagnosis) development. In spite of a great technological development, only some tractors are equipped in diagnostic systems. On board diagnosis is strongly connected with emission demands and does not concern other important vehicle functions.In...
-
An analytical hierarchy process for selection of the optimal procedure for resveratrol determination in wine samples
PublicationThe study shows the application of analytical hierarchy process (AHP) in ranking the analytical procedures, that are applied for resveratrol determination in wine samples. 19 different analytical methodologies are described by metrological, economic and environmental criteria, that are further divided into 10 subcriteria. Before AHP application, the amount of input data is decreased with cluster analysis. The first run of AHP is...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublicationThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Pneumonia, unspecified - Male, 65 - Tissue image [1203063001762871]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017621761]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017626641]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017623471]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017621051]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017627091]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017627681]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017625991]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017622011]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
The effect of adding a standard on the result of determination of polychlorinated biphenyls in bottom sediment samples
PublicationBottom sediments are a very important component of aquatic ecosystems. The sediment matrix is highly diverse and heterogeneous; in consequence, compounds entering the aquatic environment from different sources are considerably enriched at its surface. Bottom sediments are regarded as natural sorbents, since they accumulate many harmful substances, such as heavy metals and stable organic contaminants.Extraction is a key stage in...
-
Isotope-labeled substances in analysis of persistent organicpollutants in environmental samples
PublicationUltratrace analysis of persistent organic pollutants (POPs) in environmental samples requires very sophisticated methods for both sample preparation and instrumental analysis. The complex matrix requires a multi-stage procedure. Each stage is a potential source of error, as a consequence of which the final result of analysis could be a source of misinformation rather than information. The individual stages and the procedure as...
-
The Application of Fluidic Sealing in Shrouded Gas Turbine Blades
PublicationThis paper presents a study conducted on a new gas turbine designed to limit leakage in the labyrinth seal. The slots in the fin are used to generate a bypass flow, which obstructs the flow in the gap above the fin. The method was tested numerically and experimentally beforehand using a simplified model without rotation or blade passages. In this paper, the validation of the method using a model of a turbine stage is shown. Reynolds-averaged...
-
The influence of pressure drop on the working volume of a hydraulic motor
PublicationReliability and maintenance analysis of hydraulic positive machines basicly focused on the processes of their wear and failure. But in order to correctly assess the mechanical and volumetric efficiency of a hydraulic motor, both at the stage of development research or at the stage of control tests during its exploitation, the working volume of this motor must be correctly determined. Therefore this paper proposes a new method of...
-
Selective monitoring of noise emitted by vehicles involved in road traffic
PublicationAn acoustic intensity probe was developed measures the sound intensity in three orthogonal directions, making possible to calculate the azimuth and elevation angles, describing the sound source position. The acoustic sensor is made in the form of a cube with a side of 10 mm, on the inner surfaces of which the digital MEMS microphones are mounted. The algorithm works in two stages. The first stage is based on the analysis of sound...
-
Comparison and Optimization of Saccharification Conditions of Alkaline Pre-Treated Triticale Straw for Acid and Enzymatic Hydrolysis Followed by Ethanol Fermentation
PublicationThis paper concerns the comparison of the efficiency of two-stage hydrolysis processes, i.e., alkaline pre-treatment and acid hydrolysis, as well as alkaline pre-treatment followed by enzymatic hydrolysis, carried out in order to obtain reducing sugars from triticale straw. For each of the analyzed systems, the optimization of the processing conditions was carried out with respect to the glucose yield. For the alkaline pre-treatment,...
-
Wilms tumor - Female, 4 - Tissue image [5070730026201021]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026204941]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026203471]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026201971]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026201131]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [507073002620791]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026204341]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026204961]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026203061]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026207141]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026204841]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026206171]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026204501]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026204811]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026205781]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026203821]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026209831]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026209161]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Female, 4 - Tissue image [5070730026208671]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.