Filters
total: 3287
-
Catalog
displaying 1000 best results Help
Search results for: SINGLE ION MAGNET
-
Implementation of Coprocessor for Integer Multiple Precision Arithmetic on Zynq Ultrascale+ MPSoC
PublicationRecently, we have opened the source code of coprocessor for multiple-precision arithmetic (MPA). In this contribution, the implementation and benchmarking results for this MPA coprocessor are presented on modern Zynq Ultrascale+ multiprocessor system on chip, which combines field-programmable gate array with quad-core ARM Cortex-A53 64-bit central processing unit (CPU). In our benchmark, a single coprocessor can be up to 4.5 times...
-
Macro-nutrients recovery from liquid waste as a sustainable resource for production of recovered mineral fertilizer: Uncovering alternative options to sustain global food security cost-effectively
PublicationGlobal food security, which has emerged as one of the sustainability challenges, impacts every country. As food cannot be generated without involving nutrients, research has intensified recently to recover unused nutrients from waste streams. As a finite resource, phosphorus (P) is largely wasted. This work critically reviews the technical applicability of various water technologies to recover macro-nutrients such as P, N, and...
-
Integrated Experimental and Theoretical Approach for Efficient Design and Synthesis of Gold-Based Double Halide Perovskites
PublicationApplied cutting-edge electronic structure and phonon simulations provide a reliable knowledge about the stability of perovskite structures and their electronic properties, which are crucial for design of effective nanomaterials. Gold is one of the exceptional elements, which can exist both as a monovalent and a trivalent ion in the B site of a double perovskite such as A2BI BIIIX6. However, until now, electronic properties of Cs2AuI AuIIIX6...
-
Composite shells in 6-field nonlinear shell theory
PublicationW pracy przedstawiono równanie konstytutywne uwzględniające wielowarstwowość materiału powłoki. Równania wyprowadzono bazując na podejściu Equivalent Single Layer
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023445181]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023442171]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023448701]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023448221]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023444811]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [527073002345301]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023444521]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023443061]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023449401]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023446511]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023444501]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023445981]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023456741]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023441311]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023442031]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023441241]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [52707300234491]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023442051]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [5270730023445621]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [527073002344561]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mullerian mixed tumor - Female, 45 - Tissue image [527073002344481]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Characterization of 1,3-alternate calix[4]arene-silica bonded stationary phases and their comparison to selected commercial columns by using principal component analysis
PublicationTwelve calix[4]arene stationary phases in 1,3-alternate conformation, synthesized in the authors laboratory, were characterized in terms of their surface coverage, hydrophobic selectivity, aromatic selectivity, shape selectivity, hydrogen bonding capacity and ion-exchange capacity. The set of tests commonly used for evaluation of commercially available stationary phases was applied to assess fundamental chromatographic properties...
-
Calix[4]arene-Thioamides as Ionophores for Transition and Heavy Metal cations
PublicationCalix[4]arene derivatives play an important role as sensing materials in Ion Selective Electrodes(ISEs). Nowadays a high impact is put to control in natural waters the level of toxic heavy metals, like Pb ,Cd, Hg or Cu which may cause the great risk to human health. Our goal was to design and to synthesize ligands possessing ability to bind transition and heavy metal cations. The synthesis, crystal structures,extractive and ionophoric...
-
Macro-elements and Model Order Reduction for Efficient Three-Dimensional FEM Analysis
PublicationAn efficient model order reduction (MOR) methodology for three dimensional vector finite element method (FEM) is developed to accelerate simulations of the structures containing features that cause strong variations of mesh density. As the result of presented algorithm, FEM subsystems of equations corresponding to the selected refined region are converted into a very compact sets of linear equations, called macro-elements.Numerical...
-
Cation sensing by diphenyl-azobenzocrowns
PublicationMetal cations complexation and proton binding by 13- and 16-membered diphenyl-azobenzocrowns and diphenyl-hydroxyazobenzocrowns were studied in acetonitrile using spectroscopic methods: UV–vis spectroscopy, spectrofluorimetry, and 1H NMR spectroscopy. Phenyl moieties in benzene rings were found to affect binding strength alkali and alkaline earth metal cations and hydrogen ion, and affect tautomeric equilibrium of hydroxyazobenzocrowns....
-
Cross sections for ionization and ionic fragmentation of pyrimidine molecules by electron collisions
PublicationThe electron impact mass spectroscopy and the total ion collection measurements were used to investigate the ionization and ionic fragmentation of the pyrimidine, C4H4N2, molecules in the gasphase. The cation mass spectra were measured in the 10−85 amu range and the observed mass peaks assigned to corresponding ionic fragments. The most abundant cation in the mass spectra is the parent cation, C4H4N+2, at 80 amu. The appearance...
-
Mixed, quantum-classical description of electron density transfer in the collision process
PublicationIn this work, we investigate an ion-atom model describing the time-dependent evolution of electron density during the collision. For a S3+- H system, numerical simulations are based on classical trajectory calculations, and the electron density behaviour is described with the time-dependent Schrödinger equation. We apply the finite difference method to obtain quantitative insights into the charge transfer dynamics, providing detailed...
-
PHOTON LUMINESCENCE STUDIES OF TETRAHYDROFURAN FOLLOWING TRIHYDROGEN CATIONS IMPACT IN THE 20–1000 EV ENERGY RANGE
PublicationPhoton emission arising during tetrahydrofuran (C4H8O, THF) fragmentation initiated by H3 + ion impact has been studied experimentally. Luminescence fragmentation spectra and the relative emission cross-sections of the excited fragments have been measured using collision-induced emission spectroscopy in the 20–1000 eV energy range. The main features in the spectra are the H Balmer series lines, whose intensities decrease with increasing...
-
Nanosorbents as Materials for Extraction Processes of Environmental Contaminants and Others
PublicationThe aim of this work focuses on the application of nanomaterials (NMs) in different sorp- tive extraction techniques for the analysis of organic contaminants from environmental samples of distinct matrix compositions. Without any doubt, the integration of specific NMs such as carbona- ceous nanomaterials, magnetic nanoparticles (MNPs), metal–organic frameworks (MOFs), silica na- noparticles, and ion-imprinted NPs with so lid-phase...
-
Chosen Analysis Results Of The Prototype Multicell Piezoelectric Motor
PublicationThis paper presents the design, modeling and tests of the prototype multicell piezoelectric motor (MPM). A new concept of the electromechanical structure of the considered prototype is based on three rotating-mode actuators. The electromechanical structure of each actuator has been considered as an independent one - referred to as a “single cell” (single actuator). Combined three resonant actuators generate three traveling waves...
-
Techniques of acquiring additional features of the responses of individual gas sensors
PublicationGas sensors usually exhibit lack of selectivity, require fre quent calibration, exhibit drift of the response and a lot of factors, such as humidity or ambient temperature, influen ce their performance. Different approaches can be used to overcome this shortcomings. Building arrays of different sensors and usage of pattern recognition methods to analyze responses of elements...
-
New concept and analysis of the multicell piezoelectric motor
PublicationThis work presents the design, modeling and tests of the prototype multicell piezoelectric motor (MPM). A new concept of the electromechanical structure of the considered prototype is based on three rotating-mode actuators. The electromechanical structure of each actuator has been considered as an independent one - referred to as a ”single cell” (single actuator). Combined three resonant actuators generate three traveling waves...
-
Limited selectivity of amperometric gas sensors operating in multicomponent gas mixtures and methods of selectivity improvement
PublicationIn recent years, smog and poor air quality have became a growing environmental problem. There is a need to continuously monitor the quality of the air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, the selectivity of six amperometric gas sensors is investigated. First, the sensors were calibrated in order to find a correlation between the concentration...
-
Numerical study of turbulent flow and heat transfer of nanofluids in pipes
PublicationIn this work, Nusselt number and friction factor are calculated numerically for turbulent pipe flow (6 000 < Re < 12 000) with constant heat flux boundary condition using nanofluids. The nanofluid is modelled with the single-phase approach and the simulation results are compared with experimental data of Vajjha et al. [1]. Ethylene glycol and water, 60:40 EG/W mass ratio, as base fluid and SiO2 nanoparticles are used as nanofluid...
-
Multichannel self-optimizing narrowband interference canceller
PublicationThe problem of cancellation of a nonstationary sinusoidal interference, acting at the output of an unknown multivariable linear stable plant, is considered. No reference signal is assumed to be available. The proposed feedback controller is a nontrivial extension of the SONIC (self-optimizing narrowband interference canceller) algorithm, developed earlier for single-input, single-output plants. The algorithm consists of two loops:...
-
Analytical method for calculation of heat source temperature drop for the Organic Rankine Cycle application
PublicationIn the paper presented are considerations on the cooperation of the limited capacity heat source with the Organic Rankine Cycle unit. Usually the heat source providing thermal energy to the Organic Rankine Cycle (ORC) may have twofold characteristics. It can be in the form of a single phase fluid, i.e. as hot exhaust gas or hot liquid, or in some cases it may be available as a phase changing fluid, as for example, technological...
-
Turbulence model evaluation for numerical modelling of turbulent flow and heat transfer of nanofluids
PublicationIn this work, Nusselt number and friction factor are calculated numerically for turbulent pipe flow (Reynolds number between 6000 and 12000) with constant heat flux boundary condition using nanofluids. The nanofluid is modelled with the single-phase approach and the simulation results are compared with experimental data. Ethylene glycol and water, 60:40 EG/W mass ratio, as base fluid and SiO2 nanoparticles are used as nanofluid...
-
On the relationship between the structural and volumetric properties of solvated metal ions in O-donor solvents using new structural data in amide solvents
PublicationThe structures of the N,N-dimethylformamide (dmf), N,N-dimethylacetamide (dma), and N,N-dimethylpropionamide (dmp) solvated strontium and barium ions have been determined in solution using large angle X-ray scattering and EXAFS spectroscopy. The strontium ion has a mean coordination number (CN) between 6.2 and 6.8, and the barium ion has a mean CN between 7.1 and 7.8 in these amide solvents. The non-integer numbers indicates that...
-
Dissociative electron attachment to benzoic acid (C7H6O2)
PublicationThe dissociative electron attachment (DEA) to benzoic acid (C6H5COOH) has been studied using an experimental crossed beam setup of a quadrupole mass spectrometer and a trochoidal electron monochromator. Relative partial cross sections for the DEA to produce negative ion fragments show the main channels for dissociation. The comparison of the present results with the ultraviolet photoelectron spectrum of benzoic acid [J. Meeks,...
-
Calixthioamides as ionophores for transition and heavy-metal cations
PublicationThere is an increasing interest in applying p-tert-butylcalix[4]arenes as sensing materials in ion-selective electrodes(ISEs). Considerable efforts were made to design calixarenes that are selective for some heavy- or transitionmetal ions to be used in ISEs for controlling and monitoring the level of such pollutants in the environment. It has been reported that introduction of softer sulfur atoms instead of oxygen atoms in calix[4]arene...
-
Low-Power Receivers for Wireless Capacitive Coupling Transmission in 3-D-Integrated Massively Parallel CMOS Imager
PublicationThe paper presents pixel receivers for massively parallel transmission of video signal between capacitive coupled integrated circuits (ICs). The receivers meet the key requirements for massively parallel transmission, namely low-power consumption below a single μW, small area of less than 205 μm2, high sensitivity better than 160 mV, and good immunity to crosstalk. The receivers were implemented and measured in a 3-D IC (two face-to-face...
-
Attitudes towards Collaboration in Multicultural Teams in the opinion of Polish and Chinese Students
PublicationThe main goal of this paper is to present results of research that addresses the issue of attitudes towards working in both multicultural and single culture teams among Polish and Chinese students. The relationship between those attitudes and factors that includes individual experiences of research participants as well as characteristics of team tasks was analyzed. The research was conducted with students of one Polish and one...
-
Effect of the inclination angle of the condenser on the heat transfer coefficient value – experimental study
PublicationWhen considering problem of the condensation of the refrigerant in a flow inside channel, one needs to pay attention to the shape of its cross-section, the hydraulic diameter, the channel length as well as the orientation of the channel axis in space (horizontal, vertical, inclined). This paper presents an experimental study concerning the effect of the inclination angle of the condenser with a single coil pipe on the heat transfer...
-
Numerical Evaluation of Dynamic Response of a Steel Structure Model under Various Seismic Excitations
PublicationThe present paper reports the results of the study, which was designed to perform a numerical evaluation of dynamic response of a single-storey steel structure model. The experimental model was previously subjected to a number of different earthquake ground motions during an extensive shaking table investigation. The analyzed structure model was considered as a 1-DOF system with lumped parameters, which were determined by conducting...
-
Derivation of motor mean phase currents in PMSM drives operating with low switching-to-fundamental frequency ratio
PublicationPulse width modulation (PWM) of inverter output voltage causes the waveforms of motor phase cur-rents to consist of distinctive ripples. In order to provide suitable feedback for the motor current con-trollers, the mean value must be extracted from the currents’ waveforms in every PWM cycle. A com-mon solution to derive the mean phase currents is to sample their value at the midpoint of a symmetrical PWM cycle. Using an assumption...
-
Impact of digital signal processing on FOC current feedback in high-speed PMSM drive
PublicationIn applications where size and weight of the electric motor are among major design concerns, Permanent Magnet Synchronous Motors (PMSMs) with wide operational speed-range are commonly preferred. Due to limited inverter switching frequency, high-speed operation of a drive results in a low ratio between the switching frequency and the fundamental frequency of motor voltage. Such operating conditions have been recently identified...