displaying 1000 best results Help
Search results for: SIMULATION-DRIVEN%20DESIGN
-
An algorithm to generate high dense packing of particles with various shapes
PublicationDiscrete Element Method (DEM) is one of available numerical methods to compute movement of particles in large scale simulations. The method has been frequently applied to simulate the cases of grain or bulk material as the major research issue. The paper describes a new method of generating high dense packing with mixed material of two different shape used in DEM simulation. The initial packing is an important parameter to control,...
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 500 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 500 mm stroke subjected only to a mass load of 1640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 750 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1100 g
Open Research Data -
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1650 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 1650 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1650 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Zaawansowane Metody Symulacyjne dla Oceny Ekspozycji na Pole Elektromagnetyczne / Advanced Simulation Methods for Electromagnetic Exposure Assessment
ProjectsProject realized in Faculty of Electronics, Telecommunications and Informatics according to Homing Plus/2011-3/9 agreement from 2011-10-14
-
Koncepcja i symulacja polowa generatora o zmiennej częstotliwości. Zastosowanie w autonomicznych systemach elektroenergetycznych = Conception and field simulations of a variable frequency generator. Application for autonomous power generation system
PublicationStreszczenie angielskie: This paper covers a conception and simulation results for a brushless synchronous generator working with variable speed in an autonomous energy generation system (e.g. airplane power grid, hybrid vehicle, micro-CHP). The papers has two parts: presentation of the generator conception used in modern autonomous energy generation systems, and simulation results using filed model elaborated in Flux2D software....
-
MAlSim - Mobile Agent Malware Simulator
PublicationOne of the problems related to the simulation of attacks against critical infrastructures is the lack of adequate tools for the simulation of malicious software (malware). Malware attacks are the most frequent in the Internet and they pose a serious threat against critical networked infrastructures. To address this issue we developed Mobile Agent Malware Simulator (MAISim). The framework uses the technology of mobile agents and...
-
Objective selection of minimum acceptable mesh refinement for EMC simulations
PublicationOptimization of computational electromagnetics (CEM) simulation models can be costly in both time and computing resources. Mesh refinement is a key parameter in determining the number of unknowns to be processed. In turn, this controls the time and memory required for a simulation. Hence, it is important to use only a mesh that is good enough for the objectives of the simulation, whether for direct handling of high-fidelity EM...
-
Antenna Optimization Using Machine Learning with Reduced-Dimensionality Surrogates
PublicationIn modern times, antenna design has become more demanding than ever. The escalating requirements for performance and functionality drive the development of intricately structured antennas, where parameters must be meticulously adjusted to achieve peak performance. Often, global adjustments to geometry are necessary for optimal results. However, direct manipulation of antenna responses evaluated with full-wave electromagnetic (EM)...
-
Globalized Parametric Optimization of Microwave Passive Components Using Simplex-Based Surrogates
PublicationOptimization-based parameter adjustment involving full-wave electromagnetic (EM) simulation models is a crucial stage of present-day microwave design process. In fact, rigorous optimization is the only reliable mean permitting to simultaneously handle multiple geometry/material parameters, objectives, and constraints. Unfortunately, EM-driven design is a computationally intensive endeavor. While local tuning is usually manageable,...
-
Targeting Spike‐ACE2 Interface of SARS‐CoV‐2 and its Omicron Variant: A Comparative Screening of Potential Inhibitors for Existing and Anticipating Variants Using Molecular Modelling Approach
PublicationThe recent COVID pandemic has shown major impact on public health and economic crisis. Despite the development of many vaccines and drugs against the severe acute respiratory syndrome (SARS) coronavirus 2, the pandemic still persists. The continued spread of the virus is largely driven by the emergence of viral variants such as α, β, γ, delta, epsilon spike, omicron and its subvariants (BA.1,2,3) which can evade the current vaccines...
-
Machine-Learning-Based Global Optimization of Microwave Passives with Variable-Fidelity EM Models and Response Features
PublicationMaximizing microwave passive component performance demands precise parameter tuning, particularly as modern circuits grow increasingly intricate. Yet, achieving this often requires a comprehensive approach due to their complex geometries and miniaturized structures. However, the computational burden of optimizing these components via full-wave electromagnetic (EM) simulations is substantial. EM analysis remains crucial for circuit...
-
Janusz Nieznański prof. dr hab. inż.
PeopleJanusz Nieznański born in 1957 in Gdańsk. He received the M.Sc. degree in 1981, the Ph.D. degree in 1990, and the D.Sc. (‘habilitation’) degree in 1999, all from the Gdańsk University of Technology. Since 1981 he has been with the above university, where he is currently Professor of Electrical Engineering. His research and teaching interests include control, diagnostics, modeling and simulation of power electronic converters and...
-
A Circuital Model of Electric Arc in a Circuit Breaker
PublicationThe paper presents a circuital model of arc in a circuit breaker. The model is intended to be used in simulations of the electric circuits transients. It was implemented in the ATP simulation program. The article presents also a few simulation examples of simple DC and AC circuit containing described arc model.
-
Fundamentals of Physics-Based Surrogate Modeling
PublicationChapter 1 was focused on data-driven (or approximation-based) modeling methods. The second major class of surrogates are physics-based models outlined in this chapter. Although they are not as popular, their importance is growing because of the challenges related to construction and handling of approximation surrogates for many real-world problems. The high cost of evaluating computational models, nonlinearity of system responses,...
-
Comparing N3-60 cascade exit angles obtained from tunnel measurements and numerical calculations
PublicationThe article compares the results of measurements performed in the aerodynamic tunnel at CUT and numerical simulation carried out for a plane cascade of N3-60 profiles. Comparing the measured and calculated results provides opportunities for assessing the range of systematic differences between simulation predictions and actual experimental results.
-
Rapid design optimization of compact couplers using response features and adjoint sensitivities
PublicationA technique for rapid EM-driven design optimization of compact microwave couplers is presented. Our approach exploits response features and adjoint sensitivities and allows for low-cost design closure both in terms of performance enhancement and structure miniaturization. It is demonstrated using a compact rat-race coupler working at 1 GHz and compared to adjoint-based gradient optimization.
-
Comparison of Single and Multi-Population Evolutionary Algorithm for Path Planning in Navigation Situation
PublicationIn this paper a comparison of single and multi-population evolutionary algorithm is presented. Tested algorithms are used to determine close to optimal ship paths in collision avoidance situation. For this purpose a path planning problem is defined. A specific structure of the individual path and fitness function is presented. Principle of operation of single-population and multi-population evolutionary algorithm is described....
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublicationThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublicationThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
Regulator przepływu
PublicationW artykule opisano konstrukcję i wyniki badań prototypu regulatora przepływu charakteryzującego się brakiem sprężyny. W regulatorze zawór różnicowy zastąpiono zaworem stosunku ciśnień. Charakterystyki przepływowe regulatora mają przebieg niezależny od obciążenia. Nastawa regulatora odbywa się poprzez obrót hydrostatycznie odciążonej tulei dławiącej, wewnątrz której umieszczony jest suwak główny i suwak pomocniczy zaworu stosunku...
-
Mathematical Models in Design Process of Ship Bow Thrusters
PublicationThe paper describes an application of simulation models for computer-aided design of ship bow thrusters. Generation of simulation models of ship bow thruster requires development and verifying of mathematical models of system component elements. Using the results of simulation the expert system is able to determine, that the rules of classification societies are met. Design procedures and mathematical models are part of an expert...
-
Mathematical Models in Design Process of Ship Bow Thrusters
PublicationThe presentation is about an application of simulation models for computer-aided design of ship bow thrusters. Generation of simulation models of ship bow thruster requires development and verifying of mathematical models of system component elements. Using the results of simulation the expert system is able to determine, that the rules of classification societies are met. Design procedures and mathematical models are part of an...