Filters
total: 1611
-
Catalog
displaying 1000 best results Help
Search results for: MEASUREMENT SYSTEM
-
ECG measurement from the hand with elbows resting on the table top - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Signal conditioning for examination of shallow-water acoustic noise correlation properties
PublicationThe article describes the process of signal conditioning for examination of acoustic noise correlation properties in shallow water. Knowledge of these properties is very important for the design processes of passive and active hydroacoustic systems. This paper focuses on the above issue from the point of view of passive sonar. In sonar systems, signal processing algorithms operate on both useful acoustic signals, and accompanying...
-
The analysis of the accuracy of spatial models using photogrammetric software: Agisoft Photoscan and Pix4D
PublicationThis article was created as a result of research conducted within the master thesis. The purpose of the measurements was to analyze the accuracy of the positioning of points by computer programs. Selected software was a specialized computer software dedicated to photogrammetric work. For comparative purposes it was decided to use tools with similar functionality. As the basic parameters that affect the results selected the resolution...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Electrical conductivity relaxation measurements - water uptake of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataFor Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ sample was measured in the ProboStat™ measurement system. The ECR measurements were performed in air in the temperature range of 450-800 ℃ after switching water partial pressure between...
-
MEMS Technology Quality Requirements as Applied to Multibeam Echosounder
PublicationSmall, lightweight, power-efficient, and low-cost microelectromechanical system (MEMS) inertial sensors and microcontrollers, available in the market today, help reduce the instability of Multibeam Sonars. Current MEMS inertial measurement units (IMUs) come in many shapes, sizes, and costs — depending on the application and performance required. Although MEMS inertial sensors offer affordable, appropriately scaled units, they are...
-
Evaluation of the Possibility of Identifying a Complex Polygonal Tram Track Layout Using Multiple Satellite Measurements
PublicationWe present the main assumptions about the algorithmization of the analysis of measurement data recorded in mobile satellite measurements. The research team from the Gda´nsk University of Technology and the Maritime University in Gdynia, as part of a research project conducted in cooperation with PKP PLK (Polish Railway Infrastructure Manager), developed algorithms supporting the identification and assessment of track axis layout....
-
Evaluation of the Possibility of Identifying a Complex Polygonal Tram Track Layout Using Multiple Satellite Measurements
PublicationWe present the main assumptions about the algorithmization of the analysis of measurement data recorded in mobile satellite measurements. The research team from the Gda´nsk University of Technology and the Maritime University in Gdynia, as part of a research project conducted in cooperation with PKP PLK (Polish Railway Infrastructure Manager), developed algorithms supporting the identification and assessment of track axis layout....
-
Investigation of H2:CH4 plasma composition by means of spatially resolved optical spectroscopy
PublicationThe system based on spatially resolved optical emission spectroscopy dedicated for in situ diagnostics of plasma assisted CVD processes is presented in this paper. Measurement system coupled with chemical vapour deposition chamber by dedicated fiber-optic paths enables investigation of spatial distribution of species densities (Hx, H+, CH, CH+) during chemical vapour deposition process. Experiments were performed for a various...
-
Wear estimation of current collector contact strips by analysis of a 3D scanning results
PublicationThe technical condition of current collector contact strips is very important when operational reliability of railway transportation is considered. The authors proposed a novel measurement system based on a 3D camera to register the shape and dimensions of the current collector contact strips surface. The system was installed above the railway track for tests in target ambient. During the trial operation a few dozen of contact...
-
Mobilny system monitoringu jakości powietrza
PublicationZaprezentowano mobilny system monitoringu, który umożliwia kontrolę zanieczyszczeń powietrza atmosferycznego wzdłuż ciągów komunikacyjnych. W opracowanym systemie stacja monitorująca charakteryzuje się stosunkowo niewielkimi rozmiarami i zawiera układ elektroniczny autorskiego rozwiązania do pomiaru, zapisu i transmisji drogą radiową na serwer www pomierzonych stężeń związków chemicznych. Opracowane rozwiązanie jest stosunkowo...
-
System inteligentnej nawigacji sterowanej głosem
PublicationW pracy rozważa się zagadnienie wykorzystania inteligentnego systemu nawigowania oraz przeglądania serwisu Internetowego z wykorzystaniem głosu. Projekt, na podstawie przeglądu zagadnień, scala istniejące rozwiązania, które umożliwiają sterowanie portalem internetowym za pomocą głosu w języku angielskim. Użytkownik otrzymuje możliwość wydawania komend głosowych, a także zapytań odnośnie zawartości portalu. W odróżnieniu od wielu...
-
Wielokanałowy system akwizycji sygnałów wolnozmiennych
PublicationW artykule zaprezentowano urządzenie służące do pomiaru szesnastu sygnałów napięciowych wolnozmiennych. Przeznaczeniem zaprojektowanego urządzenia jest ułatwienie czynności serwisowych nowoczesnych urządzeń elektronicznych. Informacja o stanie napięć w kluczowych punktach układu (często dostępnych poprzez złącze diagnostyczne) pozwala w sposób natychmiastowy ocenić powód usterki. Założeniem projektowym było utrzymanie niskiej ceny...
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublicationWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
"Shadow" method application within endoscopic examinations of marine engines
PublicationThe paper deals with diagnostic issues concerning endoscopic examinations of the working spaces within marine diesel and gas turbine engines. In the beginning, the endoscopy apparatus being on the laboratory equipment of the Department of Ship Power Plants of Gdansk University of Technology in Poland has been characterized. The endoscopy considerations have been focused on theoretical bases of a digital image processing and especially...
-
"Shadow" method application within endoscopic examinations of marine engines
PublicationThe paper deals with diagnostic issues concerning endoscopic examinations of the working spaces within marine diesel and gas turbine engines. In the beginning, the endoscopy apparatus being on the laboratory equipment of the Department of Ship Power Plants of Gdansk University of Technology in Poland has been characterized. The endoscopy considerations have been focused on theoretical bases of a digital image processing and especially...
-
Old-timer Vehicle - Braking Efficiency Measurement at Vehicle Inspection Stations and Roadworthiness Validity Certificate.
PublicationObtaining the Roadworthiness Validity Certificate for an old-timer vehicle involves an appropriate test performance, namely, "Old-timer Vehicle Technical Specification Compliance Test". It seems obvious that this kind of test should include a considerable checklist, however, the current legal regulations connected with this test are not specific enough. One of the certificates issued on this test results is "Old-timer Vehicle Technical...
-
An inter-laboratory validation of methods of lipid peroxidation measurement in UVA-treated human plasma samples
Publication -
Downlink Capacity-Coverage Trade-off Estimation Based on Measurement of WCDMA/FDD Interface Load
PublicationThe method of capacity-coverage trade-off determination by using of universal load characteristics and normalized coverage curves for the WCDMA/FDD radio interface has been presented. The practical applications of discussed method for UMTS radio network planning process and network exploitation has been mentioned.
-
Research Protocol of the Polish Adaptation and Validation of HOPE Scale: Qualitative Measurement of Patients' Spiritual Needs
Publication -
Automatic resource identification for FPGA-based reconfigurable measurement and control systems with mezzanines in FMC standard
Publication -
Measurement of idlers rotation speed in belt conveyors based on image data analysis for diagnostic purposes
Publication -
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publication -
THE APPLICATION OF BALANCED SCORECARD METHOD FOR THE SELECTION OF FACTORS USED IN THE EFFICIENCY MEASUREMENT OF PUBLIC HOSPITALS IN POLAND
Publication -
Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine
Publication -
Urinary Measurement of 8-OxodG, 8-OxoGua, and 5HMUra: A Noninvasive Assessment of Oxidative Damage to DNA
Publication -
Myrosinase activity in different plant samples; optimisation of measurement conditions for spectrophotometric and pH-stat methods
PublicationMyrosinase found in Brassicaceae plants, is the enzyme responsible for hydrolysis of glucosinolates. As a result a variety of biologically active metabolites are liberated, whose importance in crop protection and especially in cancer chemoprevention is rapidly gaining recognition. The growing practical application of glucosinolate degradation products requires that sensitive and reliable methods of myrosinase activity determination...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
Influence of span length and impulse front time on earthing measurement accuracy of power line towers
PublicationThe article discusses the issue of measuring and assessing the features of power line tower earthings using fast-changing waveform. The study analyses the effect of impulse front time and the line span length on errors made during these measurements using impulse meters. It has been found that the assessment conditions similar to the static measurement results occur for the use of 4 μs current impulses and such procedure is useful...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublicationAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Measurement of the Temporal and Spatial Temperature Distribution on the Surface of PVCP Tissue Phantom Illuminated by Laser Dataset
PublicationThe dataset entitled Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser was obtained with a laboratory set-up for characterisation of the thermal properties of optical tissue phantoms during laser irradiation. The dataset contains a single image file representing the spatial temperature distribution on the surface of a PVCP tissue phantom. This thermal image...
-
Fatigue life improvement using low transformation temperature weld material with measurement of residual stress
PublicationWelding processes often produce high levels of tensile residual stress. Low transformation temperature (LTT) welding wires utilise phase transformation strains to overcome the thermal contraction of a cooling weld. In this paper, the residual stress within each weld was quantified using the milling/strain gauge method, being the strain change measured as the weldment was milled away. The fatigue tests were conducted under uniaxial...
-
Open extensive IoT research and measurement infrastructure for remote collection and automatic analysis of environmental data.
PublicationInternet of Things devices that send small amounts of data do not need high bit rates as it is the range that is more crucial for them. The use of popular, unlicensed 2.4 GHz and 5 GHz bands is fairly legally enforced (transmission power above power limits cannot be increased). In addition, waves of this length are very diffiult to propagate under field conditions (e.g. in urban areas). The market response to these needs are the...
-
MEASUREMENT AND ANALYSIS OF ELECTRIC FIELD INTENSITY NEAR SELECTED TRANSMITTERS OF MOBILE TELEPHONY BASE STATIONS
PublicationWireless connectivity has become increasingly common in recent times. Day by day, there are more radiocommunication devices and new ideas for them. In the near future, when the fifth generation networks will be implemented, whose main feature will be continuous wireless communication, we must approach the issue of electric field measurements more and more carefully.
-
A Set of Low-power Microcontroller-based Modules Used for Testing of Small Energy Measurement Methods
PublicationEstimation of energy consumption of low-power devices is not widely discussed in the scientific literature, but this topic is getting more and more popular. Evaluation process of newly developed methods and instrumentation requires carefull treatment. In order to fulfill this niche, the set of micro-power microcontroller based devices was proposed. The devices represent typical energy consuption profiles and allow experimental verification...
-
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublicationDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
Investigations of the Methods of Time Delay Measurement of Stochastic Signals Using Cross-correlation with the Hilbert Transform
PublicationThe article presents the results of simulation studies of four methods of estimating time delay for random signals using cross-correlation with the Hilbert Transform. Selected models of mutually delayed stochastic signals were used in the simulations, corresponding to the signals obtained from scintillation detectors in radioisotope measurements of liquid-gas two-phase flow. Standard deviations of the values of the individual functions...
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublicationThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Laser-textured cross-hatched surface topography analysis with evaluation of high-frequency measurement noise
PublicationThe precision of surface roughness determination using ISO 25178 parameters relies on various factors that directly impact the measurement process. In industry applications, the contactless roughness measurement reduces data collection time. However, it introduces several potential errors, including those stemming from the environment. One of the main types of errors encountered during topography analysis is measurement noise,...
-
A Computational Analysis of the Aerodynamic and Aeromechanical Behavior of a Thermo-Well for Steam Temperature Measurement in a Steam Turbine
PublicationThe goal of the paper is twofold: firstly, it presents computational fluid dynamics analysis for finding maximum unsteady flow forces (and their frequencies) acting on a thermo-well for measuring steam temperature in a steam turbine control stage and secondly, it presents computational solid dynamics analysis of possibility of entry into resonance of the thermowell structure. There have been analyzed two cases of flow with changing...
-
Optoelectronic properties of the metal-tetracene interface investigated by current noise measurement under monochromatic irradiation.
PublicationZaprezentowano badania prądów ograniczonych elektrodowo w warstwach tetracenu. Szczególną uwagę zwrócono na zależność szumów elektrycznych od przyłożonego napięcia i padającego światła.
-
Application of electrical capacitance tomography (ECT) to measurement of sand concentration changes during silo flow
PublicationW artykule przedstawiono wyniki doświadczeń pomiaru zmian koncentracji materiału granulowanego podczas przepływu silosowego. Zmiany zostały pomierzone przy pomocy tomografu. Doświadczenia wykonano w silosie cylindrycznym dla 2 różnych szorstkości ścian.
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Optical Parameters Stability Over Time of Porous Phantoms Mimicking Tissues
Open Research DataOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom...