Filters
total: 714
Search results for: contact temperature
-
Closed Form Constraint Equations Used to Express Frictionless Slip of Multibody Systems Attached to Finite Elements—Application to a Contact between a Double Pendulum and a Beam
PublicationThis paper focuses on the numerical modeling of the dynamics of mechanical systems. Robots that can inspect high-voltage lines inspired this research. Their control systems must anticipate potential grab positions appropriately. We intend to formulate equations dedicated to the numerical description of the robot/cable contact. The investigated problem is not straightforward, since parts of the modeled systems are numerically inhomogeneous....
-
TOXICOLOGICAL ASSESSMENT OF FOOD PACKAGES EXTRACTS
PublicationIn the scientific literature related to the widely understood issue of packaging materials designed to have contact with food (Food Contact Materials – FCM) there is much information on raw materials used for their production, their physiochemical properties, types and parameters. There is also a great number of publications on the management and disposal of used packaging. Unfortunately, not much attention is given to the matters...
-
Analysis of Measurement Errors in Rail Vehicles’ Pantograph Inspection System
PublicationThe paper presents an approach to evaluation of height measurement errors in laser scanning inspection system. The system, consisting of a laser line generator and a specialized camera, is dedicated to diagnosing carbon contact strips of railway vehicles’ pantographs. While height measurement resolution is easily computable based on system parameters, determining the measurement error is troublesome due to numerous impacts. As...
-
The assessment of microbiological antimicrobial properties of PE film loaded with nanozinc filler
Open Research DataThe dataset contains the results of a single series of determinations of the antimicrobial properties against E. coli and S. aureus of polyethylene films containing the nanozinc filler.
-
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublicationRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Mathematical modelling of the overhead contact line for the purpose of diagnostics of pantographs
PublicationThe overhead contact line (OCL) is the most effective way for supplying railway electric vehicles. The increase of the speed of the vehicles increases power consumption and requires ensuring proper cooperation of pantographs with OCL. The paper describes the novel mathematical model of the OCL system and the simulation results. The primary objective is a more accurate analysis to increase the reliability of the evaluation of monitoring...
-
EXPERIMENTAL EVALUATION OF DLC/STEEL SLIDING CONTACTS’ OPERATIONAL ENVELOPE
PublicationIn an industrial project concerning sliding bearings, a sliding pair was selected of high alloy steel vs. industrial grade DLC coated high alloy steel as a basis for an innovative design of high performance sliding bearings lubricated with a synthetic oil for use in geared transmission units. The development process required credible data on the ultimate resistance of the sliding pair to very high contact stress. An experimental...
-
The effect of depth of surface layers constituted by vacuum technologies on pitting
PublicationThe paper presents the results of a study of the effect of vacuum technologies of formation of surface layers on pitting of associated elements in a lubricated, heavy-load rolling contact. The study has shown that increase in a PVD coat depth is accompanied by decrease in the fatigue friction pair.
-
Comparative 3D DEM simulations of sand–structure interfaces with similarly shaped clumps versus spheres with contact moments.
PublicationThree-dimensional simulations of a monotonic quasi-static interface behaviour between initially dense cohesionless sand and a rigid wall of different roughness during tests in a parallelly guided direct shear test under constant normal stress are presented. Numerical modelling was carried out by the discrete element method (DEM) using clumps in the form of convex non-symmetric irregularly shaped grains. The clumps had an aspect...
-
Horizon Europe proposals - Administrative Part
Open Research DataThe dataset contains data collected during the HE National Contact Point training on Oct. 12, 2022, reg. the administrative part of Horizon Europe grant proposals. The data set includes presentations concerning administrative forms of 2022 proposals and their content, including participant data; information about abstract writing, keyword choice and...
-
Impact analysis of surface roughness of the plate-plate measuring system on resistance torque in interaction with MR fluid
PublicationMagnetorheological (MR) fluids are complex suspensions of magnetic particles in a non-magnetic carrier fluid. They exhibit ‘smart’ properties that enable them to change their rheological parameters in response to a change in the external magnetic field applied. This behavior is used in some engineering solutions, e.g. MR clutches or brakes. For such systems to work correctly, the resistance torque achieved by contact with the...
-
The effect of surfactants mixtures composition on wetting of different solid materials
PublicationThe wetting properties of surfactants mixtures were investigated. Three types of compounds were used: nonionic gemini α, α'-[2,4,7,9-tetramethyl-5-decyne-4,7-diyl]bis[ω-hydroxyl-olioxyethylene] (S-10), anionic sodium dodecyl sulphates (SDS) and cationic dodecyl trimethyl ammonium bromide (DTAB). The materials used in wetting experiments were steel and methyl polymethacrylate. These materials differ...
-
Proximal fibular osteotomy as a treatment for degenerative meniscal extrusion
PublicationMeniscal extrusion treatment is a key focus area for research and clinical study of degenerative knee pathology. The contact forces between the meniscus and the bones cause external displacements of the meniscus that are resisted by the circumferential fibres. The main risk factors for the excessive deformation of the meniscus are meniscal root tears, disruption of the circumferential fibres, knee malalignment and high body mass...
-
Influence of permanent magnetic field on wear performance of dry sliding contacts
PublicationResults of experimental studies concerning the influence of permanent magnetic field on wear of dry sliding contact are presented.It was found that magnetic field of horizontal orientation is causing temporary reduction of material's hardness. It also facilitates and accelerates removal process of wear particles from the contact zone.Formation of bulges, consisting of accumulated and compacted anti-ferromagnetic material produced...
-
Analysis of ring cracks in ceramic rolling elements using the boundary element method
PublicationCeramic materials have been increasingly used in bearing technology for over a dozen years. This is due to the characteristic properties of ceramic materials such as: high hardness, corrosion resistance, the possibility of use in aggressive chemical environments, as well as due to the lower specific weight compared to steel materials. However, the use of ceramic materials is connected with many limitations. The main disadvantages...
-
Seismic pounding behavior of multi-story buildings in series considering the effect of infill panels
PublicationThe aim of the present paper is to study the influence of the infill panels on the seismic pounding response of adjacent structures in series. The contribution of the masonry infill has been simulated using equivalent diagonal compression struts. Steel frames have been assumed to have elastic-plastic behavior with 1% linear strain hardening. The dynamic contact analysis has been utilized where contact surface model (target and...
-
Optimization of adsorption of methyl orange from aqueous solution by magnetic CoFe2O4/ZnAl-layered double hydroxide composite using response surface methodology
PublicationThe CoFe2O4/ZnAl-layered double hydroxide (LDH) composite was successfully developed through a facile co-precipitation method, characterized, and applied as an effective adsorbent for the removal of methyl orange (MO) dye from aqueous solutions. The central composite design (CCD) of the response surface methodology (RSM) was employed to estimate and optimize process variables such as initial MO concentrations, solution pH, adsorbent...
-
Detection of Closing Crack in Beam Based on Responses Induced by Harmonic Excitation
PublicationThe non-linear contact model was chosen to simulate the closed crack in the cantilever beam. The study examines the shape and characteristics of the phase diagram of a cantilever beam with closed cracks. It investigates how various crack properties influence the geometry of the phase diagram and proposes a method for identifying cracks based on their features. The area of each closed curve in the phase diagram is determined using...
-
Morphology of damage inflicted on brittle polymer in lubricated contact under cyclic static load
PublicationIn this article morphology of damage inflicted on the polymethylmethacrylate (PMMA) plate in static point lubricated contact with a ball made of five different materials under cyclic normal load has been presented. It is argued that the counterface material and lubricating film play an important role in the damage process and the extent of damage inflicted in the PMMA plate.
-
Evaluation of Langmuir and Freundlich Isotherms for Removal of Cephalexin and Tetracycline Antibiotics By Sistan Sand from Water and Wastewater Samples
PublicationIn this research, Sistan sand was used as a natural and inexpensive sorbent for removal of cephalexin and tetracycline antibiotics from water and wastewater samples. For a concentration 60.0 mg L-1 of cephalexin, optimum removal conditions were: pH of the sample 3.0, adsorbent amount 1.0 g, contact time 20.0 min, added amount of sodium chloride to adjust the ionic strength of the solution 7.0 g L-1. Langmuir isotherm was the best...
-
Three Principles for Healthy Living with Light and Lighting
PublicationThe lockdown measures applied to cities and towns during the worldwide Covid-19 pandemic have had a widespread impact on people’s lives. Some have found themselves confined to their homes, with limited social contact and a reduced quality of life. Others have found that the lockdown improved their wellbeing, as more time was spent outside, instead of commuting and working in an office building, plus the benefits of spending increased...
-
Micro-modelling of shear localization during quasi-static confined granular flow in silos using DEM
PublicationThe paper deals with the quasi-static confined flow of cohesionless sand in a plane strain model silo with parallel walls and a slowly movable bottom. Numerical modelling was carried out by the discrete element method (DEM) using spheres with contact moments to approximately capture a non-uniform shape of sand particles. Different initial void ratios of sand and silo wall roughness grades were employed. Regular triangular grooves...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_004)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0020)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0024)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0019)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0023)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0017)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0021)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_005)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_003)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_002)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_007)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_006)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0010)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0011)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_008)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_009)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0012)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
The AFM micrographs of gold nanoparticles on silicon substrate
Open Research DataThe dataset contains the first approach towards AFM topographic imaging of gold nanoparticles synthesized and immobilized on the silicon surface. Measurements were made in the semi-contact mode on the NTEGRA Prima device, manufactured by NT-MDT. Scans were performed with amplitude detection at an operating value of 60% of the free oscillation amplitude....
-
Wear of Ultra-thin DLC or Tungsten-modified DLC Coatings under Reciprocating Sliding
PublicationIn the paper results are presented from tests in reciprocating sliding of self mated specimens of DLC and tungsten modified DLC coatings on stainless steel substrate. The contact geometry chosen for the research task was ball on flat. The contacts were lubricated either with distilled water or medical saline solution. Results are presented with regard to wear resistance as a function of material type and lubricant used.
-
Force-deformation spectroscopy in contact mode
Open Research DataThe deformation-distance spectroscopic curve is obtained by registering the value of the probe cantilever deflection as a function of the elongation of the piezoelectric scanner. It assumes a simple relationship in the form of Hooke’s law, linking the deformation of the lever with the amount of its deflection caused by the proximity of the probe and...
-
Multi-stage magnetic-fluid seals for operating in water - life test procedure, test stand and research results
PublicationThe edge criteria for magnetic-fluid seals durability research are critical for the seal'stechnological usefulness. The magnetic fluid seal technology in water is much moredifficult technological problem in comparison to gas or vacuum environment. There isalways problem with immediate contact between magnetic fluid and the environmentaluninspected liquids. In the paper are presented ways of experiments definitions carried outwith...
-
Influence of meniscus shape in the cross sectional plane on the knee contact mechanics
PublicationWe present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with partial and complete radial posterior meniscus root...
-
Life tests of a rotary single-stage magnetic-fluid seal for shipbuilding applications
PublicationUse of the magnetic fluid seal technology in water is much more difficult technological problem in comparisonto gas or vacuum environment. Some seals constructed up to time been are designed as hybrid, two stagesealing structures with shields or mechanical seals used as protection measures to the magnetic fluid seal.Anyway, there is always problem with immediate contact between magnetic fluid and the environmentalliquid. In the...
-
Improving Accuracy of Respiratory Rate Estimation by Restoring High Resolution Features With Transformers and Recursive Convolutional Models
PublicationNon-contact evaluation of vital signs has been becoming increasingly important, especially in light of the COVID- 19 pandemic, which is causing the whole world to examine people’s interactions in public places at a scale never seen before. However, evaluating one’s vital signs can be a relatively complex procedure, which requires both time and physical contact between examiner and examinee. These re- quirements limit the number...
-
Influence of concentration on contact angle of water-Cu nanofluid on glass substrate
PublicationIn the paper the results of an experimental investigation of influence of nanoparticle concentration on contact angle of water-Cu nanofluid on glass substrate have been presented. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. In the present study copper was applied as nanoparticle while distilled, deionized water was used as a base fluid. The mean diameter of nanoparticle is estimated to be 50...
-
AUGMENTATION OF THE CRITICAL HEAT FLUX IN WATER-Al2O3, WATER-TiO2 AND WATER-Cu NANOFLUIDS
PublicationThe main aim of the proposed study is therefore recognition of the phenomena accompanying nucleate boiling crisis of selected nanofluids during boiling on horizontal tubes of various outside diameters. Of particular interest is impact of contact angle and tube diameter on the value of critical heat flux. The results obtained should give more light on the nature of nucleate boiling crisis and will serve as a basis for future theoretical...
-
Comparative modeling of shear localization in granular bodies with FEM and DEM
PublicationThe intention of the paper is to compare the calculations of shear zones in granular bodies using two different approaches: a continuum and a discrete one. In the first case, the FEM based on a micro-polar hypoplastic constitutive law was used. In the second case, the DEM was taken advantage of, where contact moments were taken into account to model grain roughness. The comparative calculations were performed for a passive case...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K08
Open Research DataOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig:...