Filters
total: 1242
-
Catalog
displaying 1000 best results Help
Search results for: MEASUREMENT SYSTEMS
-
The impact of slowly biodegradable organic compounds on the oxygen uptake rate in activated sludge systems
PublicationThe hydrolysis process of slowly biodegradable substrate (Xs) have impact on the efficiencies of nutrient removal in activated sludge systems. Measurement of OUR and corresponding COD is accepted as a very useful tool to reflect the consumption of biodegradable substrates. The influence of the readily biodegradable substrate (Ss) in biological wastewater treatment systems has been extensively investigated, but little is known about...
-
The impact of slowly biodegradable organic compounds on the oxygen uptake rate in activated sludge systems
PublicationThe hydrolysis process of slowly biodegradable substrate (Xs) have impact on the efficiencies of nutrient removal in activated sludge systems. Measurement of OUR and corresponding COD is accepted as a very useful tool to reflect the consumption of biodegradable substrates. The influence of the readily biodegradable substrate (Ss) in biological wastewater treatment systems has been extensively investigated, but little is known about...
-
Evaluation and behaviour of slowly biodegradable substrate on mathematical modelling of oxygen uptake rate in activated sludge systems
PublicationThe effect of the readily biodegradable (Ss) fraction in activated sludge systems has been extensively investigated, but only minor information can be found about the effect of Xs on OUR in activated sludge systems. The aim of this study was to determine the evaluation and behaviour of Xs on mathematical modelling of OUR using ASM2d and its modification. The essential study was divided into two major parts: experimental investigation...
-
PULSE and ECG measurement from the hand with elbows in the air - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
DOP and Pseudorange Error Estimation in Mobile GNSS Systems for Android OS Applications
PublicationIn the near past, GNSS (Global Navigation Satellite Systems) were only offered for a narrow group of recipients. Nowadays, thanks to mobile devices, they are available to anyone and everywhere. Personal navigation, searching for POI (Point of Interest), etc., had become a basic essential activity. Thanks to the widespread and availability of smartphones each user can obtain information considering his or her location even in an...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Hydrodron — New Step for Professional Hydrography for Restricted Waters
PublicationHydrographic surveys in restricted areas are becoming increasingly important, but often impossible to carry out with conventional hydrographic vessels. Presumably in this case an employment of unmanned vehicles is the only reasonable solution. As restricted water areas include, among others: harbours, roadsteads, rivers or lakes. The HydroDron platform, due to its mobility, can operate in the above-mentioned areas. It is adapted...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Dynamic unattended measurement based routing algorithm for diffServ architecture
PublicationDynamic routing is very important in terms of assuring QoS in today's packet networks especially for streaming and elastic services. Existing solutions dedicated to dynamic routing are often too complicated and seem to be not usable in real time traffic scenarios where transferred traffic may vary significantly. This was the main reason for research and new routing mechanism proposal which should apply to today's packet networks....
-
Measurement of engine and vehicle parameters using onboard CAN network
PublicationWspółczesne samochody wyposażane są w dużą liczbę układów elektronicznych, które wymagają wzajemnej wymiany informacji. Techniczne problemy niezależnego łączenia ze sobą dużej liczby sterowników doprowadziły do powstania pokładowych sieci wymiany danych. Do najpopularniejszych z nich zalicza się obecnie system CAN. W pracy przedstawiono metodę rozpoznawania ramek wiadomości transmitowanych w pokładowej sieci CAN pojazdu przez sterowniki....
-
Measurement of benzene concentration in urban air using passive sampling
PublicationAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Drift, wow and flutter measurement and reduction in shrunken movie soundtracks
PublicationReferat przedstawia metodę i algorytmy do oceny i redukcji dryfu, kołysania i drżenia w skurczonych taśmach filmowych. Przedstawione algorytmy działają w oparciu o przetwarzaniu obrazu taśmy filmowej w celu wyznaczenia jej lokalnego skurczu, który jest jednym z powodów powstawania dryfu, kołysania i drżenia. Lokalny skurcz taśmy można wyznaczyć dzięki analizie wysokości: ramki obrazu, perforacji, lub innego, standaryzowanego elementu...
-
On-line measurement of cell impedance during charging and discharging process
PublicationW pracy przedstawiono założenia metody pomiaru impedancji, która w przeciwieństwie do dotychczasowych technik impedancyjnych stosowanych w badaniach ogniw, umożliwia pracę on-line. W celu zaprezentowania możliwości metody wykonano eksperyment polegający na cyklicznym ładowaniu i rozładowywaniu elektrody ołowianej w 4.8M H2SO4 z jednoczesnym pomiarem impedancji. Zmiany parametrów elektrycznych otrzymanych w wyniku analizy widm impedancyjnych...
-
Continuous-time delay system identification insensitive to measurement faults
PublicationW pracy wykorzystuje się algorytmy identyfikacji do estymacji parametrów systemów ciągłych z opóźnieniem. Zastosowanie filtrów całkujących ze skończonym horyzontem obserwacji pozwala przekształcić równanie różniczkowe opisujące system ciągły do użytecznej postaci regresyjnej z czasem dyskretnym. Uzyskany w ten sposób i zachowujący oryginalną parametryzację model dyskretny daje się identyfikować stosując klasyczną metodę najmniejszych...
-
Theoretical and Measurement Investigations of DS CDMA Signal Detection Problem
PublicationPrzedstawiono opis teoretyczny wybranej motody wykrywania sygnałów z widmem rozproszonym DS CDMA. Przedstawiono prototypowe stanowisko laboratoryjne do wykrywania sygnałów DS CDMA i zaprezentowano wyniki pomiarowe.
-
Measurement accuracy evaluation of transmission line earthings by impulse tests
PublicationUziemienia słupów linii energetycznych powinny być sprawdzane okresowo. Pomiary rezystancji takich uziemień przy pomocy metody niskoczęstotliwościowej wymaga wyłaczania linii i odkręcania przewodów odprowadzających od konstrukcji słupa. Metoda udarowa jest znacznie łatwiejsza w tej aplikacji i nie wymaga wyłaczania linii na czas pomiarów. W pracy oszacowano wpływ uziemień sąsiednich słupów na dokładność pomiarów metodą udarową.
-
Quality of Analytical Results: Classifiying Errors and Estimating Measurement Uncertainty
Publication -
Cost‐effectiveness of blood pressure measurement and hypertension follow‐up
Publication -
<title>Measurement and control of field in RF GUN at FLASH</title>
Publication -
Setups for measurement of thermal time constant of bolometers and resistive layers
PublicationPrzedstawiono dwa układy do pomiaru termicznej stałej czasowejbolometrów i warstw rezystywnych, umożliwiające pomiar wartości tego parametru w zakresie od pojedynczych milisekund do kilku sekund. Przedstawiono wyniki pomiarów termicznej stałej czasowej wybranych warstw rezystywnych wykonanych w technologii LTCC z niestechiometrycznych tlenków lantanowo-strontowo-żelazowych oraz bolometru cienkowarstwowego wykonanego w tej samej...
-
The Effect of the Phenomenon of “Spectrum Leakage” on the Measurement of Power Quality Parameters
Publication -
A Method of Lathe Checks Measurement; SMOF device and its software
Publication -
Analysis of Uncertainty of the Emission Measurement of Gaseous Pollutants on Chassis Dynamometer
Publication -
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublicationMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Measurement of Coherence Bandwidth in UHF Radio Channels for Narrowband Networks
PublicationThis paper presents results of investigation on the coherence bandwidth of narrowband radio channels in 430MHz band. The coherence bandwidth values were estimated froma power delay profile obtained by recording CDMA2000 forward channel signals during real-fieldmeasurements in various environments:mediumcity, flat terrain, and hilly terrain in northern Poland.The results of measurements are compared with characteristic parameters...
-
IMPEDANCE MEASUREMENT MODULE FOR GAS SENSORS WITH TEMPERATURE CONDITIONING FEATURE
PublicationThe paper presents an impedance measurement module which is aimed for gas sensor. Sensor’s heater temperature conditioning and modulation feature is available in order to allow implementation of different techniques improving selectivity and sensitivity of gas sensors. The measurement module uses three-parameter sine-fitting technique for impedance measurement. To monitor sensor temperature, the resistance of the sensor’s heater...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...