Filters
total: 7742
-
Catalog
- Publications 5646 available results
- Journals 19 available results
- Conferences 2 available results
- People 64 available results
- Projects 1 available results
- Laboratories 1 available results
- Research Equipment 1 available results
- e-Learning Courses 56 available results
- Events 2 available results
- Open Research Data 1950 available results
displaying 1000 best results Help
Search results for: low-level features
-
Development of an emulation platform for synchronous machine power generation system using a nonlinear functional level model
PublicationThe article presents the Power Hardware in the Loop (PHIL) approach for an autonomous power system analysis based on the synchronous generator model incorporating magnetic saturation effects. The model was prepared in the MATLAB/Simulink environment and then compiled into the C language for the PHIL platform implementation. The 150 kVA bidirectional DC/AC commercial-grade converter was used to emulate the synchronous generator....
-
Influence of traffic schemes on the level of vessels safety / WPŁYW TYPU SKRZYŻOWANIA NA POZIOM BEZPIECZEŃSTWA STATKÓW
Publication -
Preconditioners with Low Memory Requirements for Higher-Order Finite-Element Method Applied to Solving Maxwell’s Equations on Multicore CPUs and GPUs
PublicationThis paper discusses two fast implementations of the conjugate gradient iterative method using a hierarchical multilevel preconditioner to solve the complex-valued, sparse systems obtained using the higher order finite-element method applied to the solution of the time-harmonic Maxwell equations. In the first implementation, denoted PCG-V, a classical V-cycle is applied and the system of equations on the lowest level is solved...
-
Low energy inelastic electron scattering from carbon monoxide: I. excitation of the a3Π, a’3Σ+ and AΠ1 electronic states.
PublicationDifferential scattering cross sections for electron excitation of the three lowest excited electron states of carbon monoxide are obtained experimentally using low-energy electron energy-loss spectroscopy and theoretically using the R-matrix method. The incident electron energies range from near-threshold of 6.3 eV to 20 eV. Experimental scattering angles range from 20◦ to 120◦. The normalization of the experimental cross sections...
-
Low-Power Receivers for Wireless Capacitive Coupling Transmission in 3-D-Integrated Massively Parallel CMOS Imager
PublicationThe paper presents pixel receivers for massively parallel transmission of video signal between capacitive coupled integrated circuits (ICs). The receivers meet the key requirements for massively parallel transmission, namely low-power consumption below a single μW, small area of less than 205 μm2, high sensitivity better than 160 mV, and good immunity to crosstalk. The receivers were implemented and measured in a 3-D IC (two face-to-face...
-
Endometrial stromal sarcoma, low grade - Female, 46 - Tissue image [1270630012691091]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 46 - Tissue image [1270630012696181]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 46 - Tissue image [1270630012696821]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 46 - Tissue image [1270630012694831]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 46 - Tissue image [1270630012691311]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 46 - Tissue image [1270630012692991]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 46 - Tissue image [1270630012699851]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multi-fidelity EM simulations and constrained surrogate modelling for low-cost multi-objective design optimisation of antennas
PublicationIn this study, a technique for low-cost multi-objective design optimisation of antenna structures has been proposed. The proposed approach is an enhancement of a recently reported surrogate-assisted technique exploiting variable-fidelity electromagnetic (EM) simulations and auxiliary kriging interpolation surrogate, the latter utilised to produce the initial approximation of the Pareto set. A bottleneck of the procedure for higher-dimensional...
-
Low energy inelastic electron scattering from carbon monoxide: II. Excitation of the b3Σ+, j3Σ+, B1Σ+, C1Σ+ and E1Π Rydberg electronic states
PublicationIn this second part of a two part paper (first part: Zawadzki et al (2020 J. Phys. B: At. Mol. Opt. Phys. 53 165201)) we present differential scattering cross sections for excitation of several Rydberg electronic states of carbon monoxide by electron impact. The first part concerned the low-lying valence states of CO. In the present study cross sections are obtained experimentally using low-energy electron energy-loss spectroscopy...
-
Endometrial stromal sarcoma, low grade - Female, 42 - Tissue image [1270630012692851]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 42 - Tissue image [1270630012698271]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 42 - Tissue image [1270630012695391]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 42 - Tissue image [127063001269961]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 42 - Tissue image [1270630012692111]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 42 - Tissue image [127063001269641]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 42 - Tissue image [1270630012695581]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 42 - Tissue image [1270630012699461]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 42 - Tissue image [127063001269761]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Combined cold supply system for ship application based on low GWP refrigerants - Thermo-economic and ecological analyses
PublicationThe withdrawal of popular high-GWP refrigerants will significantly affect maritime industry. Refrigeration and air conditioning systems currently used on ships are not ready to fulfil future limitations. Therefore, there is a need for system, which will operate with low-GWP refrigerants and at the same time will be efficient and reliable in difficult environmental conditions. This paper explains the concept of a cold supply system,...
-
Low-dimensional bound entanglement with one-way distillable cryptographic key
PublicationIn this paper, we provide a class of bound entangled states that have positive distillable secure key rate. The smallest state of this kind is 4 circle times 4, which shows that peculiar security contained in bound entangled states does not need high-dimensional systems. We show that for these states a positive key rate can be obtained by one-way Devetak-Winter (DW) protocol. Subsequently, the volume of bound entangled key-distillable...
-
Shaping coherence function of sources used in low-coherent measurement techniques
PublicationW niskokoherencyjnych technikach pomiarowych kształt funkcji koherencji wykorzystywanego źródła ma bezpośredni wpływ na parametry metrologiczne układu pomiarowego. Z tego względu, w wielu aplikacjach niezbędne jest użycie metod pozwalających na zmianę kształtu tej funkcji. W artykule przeanalizowano możliwości kształtowania funkcji koherencji, a przedstawione analizy teoretyczne i wyniki symulacji komputerowych wskazują, że kształtowanie...
-
A low-band gap, nitrogen-modified titania visible-light photocatalyst
PublicationFotokatalizatory tlenku tytanu(IV) zmodyfikowanego azotem zostały zsyntetyzowane poprzez ogrzewanie wodorotlenku tytanu i mocznika w temperaturze 400ºC. Otrzymane fotokatalizatory charakteryzują się silną absorpcją w zakresie promieniowania widzialnego (400-500 nm) odznaczając się niskimi wartościami energii pasma wzbronionego (2,20 i 2,46 eV). Aktywność fotokatalityczną w świetle widzialnym potwierdzono przeprowadzając reakcję...
-
A virtual instrument for the adaptive analysis of low-frequency magnetic-field emissions
Publication -
High temperature corrosion of evaporator tubes in low-emission steam boilers
PublicationW artykule opisano zjawisko korozji wysokotemperaturowej rur ekranowych kotłów parowych niskoemisyjnych. Przeprowadzono badania rur po eksploatacji. Wykonano badania składu chemicznego zgorzelin. Stwierdzono, że główną przyczyną pocienienia rur na wyższych poziomach jest korozja siarkowa, natomiast na poziomach niższych oddziaływanie stopionych soli.
-
Regulation of replication of λ phage and λ plasmid DNAs at low temperature
Publication -
Chiral crystals from porphyrinoids possessing a very low racemization barrier
Publication -
Low-temperature air plasma modification of chitosan-coated PEEK biomaterials
Publication -
Effect of low-temperature plasma on chitosan-coated PEEK polymer characteristics
Publication -
Novel catalysts for low temperature synthesis of single wall carbon nanotubes
Publication -
Grouts with highly thermally conductive binder for low-temperature geothermal applications
Publication -
Tracts of high or low sequence divergence in the mouse major histocompatibility complex.
Publication -
Low and high field sites of Cr3+ ions in calcium tetraborate glasses
Publication -
Metal Oxides and Low Temperature SWCNT Synthesis via Laser Evaporation
Publication -
Neural Networks in the Diagnostics Process of Low-Power Solar Plant Devices
Publication -
Effects of Base π-Stacking on Damage to DNA by Low-Energy Electrons
Publication -
Shaping coherence function of sources used in low-coherent measurement techniques
Publication -
Dynamic current-voltage characteristics of dielectrics with extremely low heat conductivity
PublicationZaprezentowano teoretyczny opis metody dynamicznych charakterystyk prądowo-napięciowych w przypadku znacznego gradientu temperatury w ciałach stałych o przewodności jonowej. Otrzymano rozwiązania równania transportu oraz równania charakterystyk, odnoszące się do ruchu cienkiej warstwy nośników ostałej grubości oraz warstwy rozszerzającej się. Podano także przybliżone wyrażenia opisujące czas przelotu nośników. Wyniki zweryfikowano...
-
Measurement of noise parameter set in the low frequency range: requirements and instrumentation.
PublicationOpisano dwa podstawowe szumowe modele metrologiczne czwórnika: ze źródłami szumów odniesionymi do wejścia i ze zwarciowymi prądami szumów. Parametry szumowe opisujące modele zawierające korelację pomiędzy prądami i/lub napięciami są mierzone przy zastosowaniu metod bezpośrednich i pośrednich. Przedstawiono kilka technik redukcji szumów własnych systemu pomiarowego. Szerzej zaprezentowano dwukanałowy system do pomiaru szumów z komputerowym...
-
A Surrounding World Knowledge Acquiring by Using a Low-cost Ultrasound Sensors
Publication -
Sensitivity performance of all pole canonical low pass GmC filters.
PublicationW pracy badano własności częstotliwościowe kanonicznych filtrów dolnoprzepustowych GmC bez zer transmisyjnych. Przedstawiono ogólną strukturę kanonicznego filtru dolnoprzepustowego i jej opis macierzowy. Wyprowadzono ogólne wzory określające funkcje wrażliwościowe filtru. Dokonano porównania struktur do 10-go rzędu włącznie dla aproksymacji Butterwortha, Czebyshewa i Bessela.
-
Low frequency noise and DLTS as silicon solar cell characterization tools
PublicationPraca zawiera wyniki pomiarów DLTS próbek o powierzchni 1 mm2 krzemowych baterii słonecznych wykazujących znaczne niejednorodności wykryte za pomocą metody LBIV (Light Beam Induced Voltage). Wyniki pomiarów charakterystyk stałoprądowych oraz szumowych tych próbek zostały także przedstawione.
-
Hydrogen-enhanced stress corrosion cracking in low alloy steels in seawater
PublicationBadano podatność stali niskostopowych w wodzie morskiej w warunkach polaryzacji katodowej. Stwierdzono spadek czasu do zniszczenia, energii zniszczenia i przewężenia ze wzrostem potencjału katodowego. Wykazano znaczącą korelację między stopniem degradacji wodorowej a stężeniem wodoru dyfuzyjnego.
-
Low order autoregressive (AR) models for FDTD analysis of microwave filters.
PublicationArtykuł opisuje zastosowanie modeli AR w celu poprawy efektywności analizy struktur filtrujących metodą różnic skończonych w dziedzinie czasu (FD-TD). Opisanych jest szereg kryteriów pozwalających na automatyczne tworzenie modeli AR sygnałów czasowych, w tym wybór fragmentu odpowiedzi układu stanowiący podstawę ekstrakcji współczynników modelu, współczynnika decymacji oraz rzędu modelu. Skuteczność wprowadzonych kryteriów...
-
Weldability of S460ML High Strength Low Alloy Steel in Underwater Conditions
PublicationThe paper presents experimental evaluation of susceptibility of the high strength S460ML steel to cold cracking in the conditions of wet welding with the use of covered electrodes. From the results of Tekken tests it was found out that the investigated steel was characterised, in the conditions of the carried out experiments (underwater wet welding and air welding with rutile electrodes), of high susceptibility to cold cracking....
-
The low energy house using an air solar collector - a case study
PublicationCelem tego artykułu jest przedstawienie możliwości ogrzewania i chłodzenia domu jednorodzinnego przy wykorzystaniu słonecznych kolektorów powietrznych. W analizie uwzględniono dom energooszczędny, którego wskaźnik sezonowego zapotrzebowania na ciepło wynosi 40kWh/m2/a. Do obliczeń przyjęto kolektory powietrzne dostępne na rynku o powierzchni 60m2 i wydajności wynoszącej 70%. W analizowanym budynku występuje prawie pełne pokrycie...