Search results for: NON-STANDARD%20DIFFERENCE%20METHODS
-
Non-standard contact conditions in generalized continua: microblock contact model for a Cosserat body
PublicationGeneralized continuum theories involve non-standard boundary conditions that are associated with the additional kinematic variables introduced in those theories, e.g., higher gradients of the displacement field or additional kinematic degrees of freedom. Accordingly, formulation of a contact problem for such a continuum necessarily requires that adequate contact conditions are formulated for the additional kinematic variables and/or...
-
Non-standard binary weighted number systems
PublicationZdefiniowano szeroką klasę binarnych systemów wagowych. Wszystkie sa wzajemnie jednoznaczne ale mogą być zupełne lub niezupełne. Jeżeli wagi systemu są kolejnymi liczbami naturalnymi to system jest minimalny.Jesli wagi sa kolejnymi potęgami podstawy Z to system jest maksymalny. W przestrzeni między tymi systemami znajdują się inne systemy binarne. Kilka z nich przedstawiono w referacie.
-
Compact 4 × 4 butler matrix with non‐standard phase differences for IoT applications
PublicationButler matrices represent a popular class of feeding networks for antenna arrays. Large dimensions and the lack of flexibility in terms of achievable output phase difference make conventional Butler structures of limited use for modern communication devices. In this work, a compact planar 4 × 4 matrix with non-standard relative phase shifts of –30º, 150º, –120º, and 60º has been proposed. The structure is designed to operate at...
-
Non-matrix reference matrials- chalanges in the preparation of standard gas mixtures
PublicationIn the last few years particularly great pressure is exerted on quality control and assurance of analytical measurement results. An invaluable role in this process is played by reference materials. The paper presents the characteristics of basic types of reference materials, with particular attention to gaseous reference materials. In addition, a review of literature on techniques of preparation of gaseous standard materials, published...
-
Non-matrix reference materials-the challenges in the preparation of standard gas mixtures
PublicationIn the last few years particularly great pressure is exerted on quality control and assurance of analytical measurement results. An invaluable role in this process is played by reference materials. The paper presents the characteristics of basic types of reference materials, with particular attention to gaseous reference materials.
-
Design of IIR digital filters with non-standard characteristics using differential evolution algorithm
PublicationW artykule przedstawiono zastosowanie algorytmu ewolucji różnicowej do projektowania filtrów cyfrowych o niestandardowych charakterystykach. Przy użyciu tego algorytmu zaprojektowano trzy filtry z charakterystykami amplitudowymi: liniowo narastającą, liniowo opadającą i nieliniowo narastającą. Filtry uzyskane tą metodą są stabilne i ich charakterystykispełniają wszystkie założenia projektowe.
-
Design and optimization of IIR digital filters with non-standard characteristics using continuous ant colony optimization algorithm
PublicationW pracy przedstawiono metodę projektowania i optymalizacji stabilnych filtrów cyfrowych IIR o niestandardowych charakterystykach amplitudowych, przy zastosowaniu ''mrówkowego'' algorytmu optymalizującego ACO. W proponowanej metodzie (nazwanej ACO-IIRFD), wprowadzono dynamiczne zmiany parametrów. Dzięki tym zmianom parametrów filtru cyfrowego możliwe jest uzyskanie małych odchyłek charakterystyk między założonymi i aktualnymi....
-
Waldemar Kamiński prof. dr hab. inż.
People1978 - 1985 The Office for Geodesy and Rural Areas in Elbląg 1985 - 2017 University of Warmia and Mazury in Olsztyn 2017 - present Gdańsk University of Technology Science specialisation: non-standard geodetic calculations
-
Zero phase shift digital filtering for assessment of exposure to non-sinusoidal magnetic fields
PublicationAccuracy of assessment of human body exposure to magnetic fields is affected by several uncertainty sources. One of them is estimation of the total exposure to non-sinusoidal fields. Standard methods can be implemented using analogue or digital filters that introduce a phase shift that affect the result of total exposure level estimation. The paper presents a new method that allows performing more precise assessment of exposure...
-
Blob - standardowa architektura przyszłości?
PublicationRelacja z konferencji ''Non-standard Praxis'', Massachusetts Institute of Technology, Cambridge, USA, 24-26 września 2004, traktującej o współczesnej praktyce architekta w dobie cyfrowych technologii.
-
Non-Newtonian Mathematics Instead of Non-Newtonian Physics: Dark Matter and Dark Energy from a Mismatch of Arithmetics
PublicationNewtonian physics is based on Newtonian calculus applied to Newtonian dynamics. New paradigms such as ‘modified Newtonian dynamics’ (MOND) change the dynamics, but do not alter the calculus. However, calculus is dependent on arithmetic, that is the ways we add and multiply numbers. For example, in special relativity we add and subtract velocities by means of addition β1⊕β2=tanh(tanh−1(β1)+tanh−1(β2)), although multiplication β1⊙β2=tanh(tanh−1(β1)⋅tanh−1(β2)),...
-
A universal standard for health-promoting places. Example of assessment -on the basis of a case study of Rahway River Park
PublicationThe purpose of this paper is to contribute to development of approaches to the evaluation of the design of public open green spaces (POS). This paper presents a universal standard for the design of health-promoting urban places. The standard is a conceptual framework which was developed after visiting over one hundred public parks and therapeutic gardens in Europe and the United States. The universal standard is a simple and...
-
Failure of cold-formed beam: How does residual stress affect stability?
PublicationIn machine industry, stresses are often calculated using simple linear FEM analysis. Occasional failures of elements designed in such a way require recomputation by means of more sophisticated methods, eg. including plasticity and non-linear effects. It usually leads to investigation of failure causes and improvement of an element in order to prevent its unwanted behavior in the future. The study presents the case where both linear...
-
Simple Fractal Calculus from Fractal Arithmetic
PublicationNon-Newtonian calculus that starts with elementary non-Diophantine arithmetic operations of a Burgin type is applicable to all fractals whose cardinality is continuum. The resulting definitions of derivatives and integrals are simpler from what one finds in the more traditional literature of the subject, and they often work in the cases where the standard methods fail. As an illustration, we perform a Fourier transform of a real-valued...
-
Fast method for IEEE 802.16-2004 standard-based networks coverage measuring
PublicationThis paper presents the time and cost efficient method for measuring effective coverage of IEEE 802.16-2004 standard-based networks. This is done by performing a series of continuous measurements on the grid basis. Due to this kind of signal quality surveying, estimationof the probable coverage area can be made. It is significant that themethod is fast and is uses a standard customer equipment which makes it more accessible for...
-
Verification of punching shear outside the shear cap by the direct method
PublicationThe proposition of a method to verify the punching resistance for very large supports based on the EN 1992-1-1 standard is described in this paper. The present standard guidelines for the calculation of the punching resistance for large supports are also summarised. The proposed direct method is compared with other standard methods using an example taken from design practice. This method consists of a direct check of the shear...
-
On Solvability of Boundary Value Problems for Elastic Micropolar Shells with Rigid Inclusions
PublicationIn the framework of the linear theory of micropolar shells, existence and uniqueness theorems for weak solutions of boundary value problems describing small deformations of elastic micropolar shells connected to a system of absolutely rigid bodies are proved. The definition of a weak solution is based on the principle of virial movements. A feature of this problem is non-standard boundary conditions at the interface between the...
-
Thermal self-action effects of acoustic beam in a vibrationally relaxing gas
PublicationThermal self-action of acoustic beam in a molecular gas with excited internal degrees of molecules’ freedom, is studied. This kind of thermal self-action differs from that in a Newtonian fluid. Heating or cooling of a medium takes place due to transfer of internal vibrational energy. Equilibrium and non-equilibrium gases, which may be acoustically active, are considered. A beam in an acoustically active gas is self-focusing unlike...
-
Analysis of EN 1993-1-6 guidelines about determining amplitudes of equivalent imperfections of steel cylindrical shells subjected to uniform external pressure
PublicationCivil engineering structures should be designed with reference to relevant standards. One of them is a Eurocode 3 standard EN 1993-1-6:2007: Design of steel structures Part 1-6: Strength and Stability of Shell Structures. According to this standard, the value of buckling load can be determined using different approaches: classical hand calculations (stress design) and geometrical and material non-linear analysis of an imperfect...
-
Interaction of Acoustic and Thermal Modes in the Gas with Nonequilibrium Chemical Reactions: Possibilities of Acoustic Cooling
PublicationNonlinear generation of thermal mode during propagation of dominative sound in a chemically reacting gas is considered. The dynamic equation of excess temperature associated with the thermal mode is derived. It is instantaneous and includes quadratic nonlinear acoustic source reflecting the nonlinear character of interaction between acoustic and non-acoustic types of gas motion. Both periodic and aperiodic sound may be considered...
-
Assessment of unusual failure in crankshaft of heavy-duty truck engine
PublicationThe unusual premature failure of a heavy-duty truck engine crankshaft has been the subject of a rigorous study, and this manuscript describes it in detail. The failure was happened to begin with the growth of the crack from the surface defects, in the form of the clusters of non-metallic inclusions, in the lubrication hole zone of the first main journal, which was the stress concentration zone. A series of experiments including...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...