Search results for: biomechanics
-
Friction and flow around growing tissue in bioreactor. Proceedings of the Biomechanics 2003. Engineering Biomechanics - Biomechanics of Sport - Medical Biomechanics.
PublicationPrzedstawione zostały problemy teoretyczne związane z wyznaczaniem sił tarcia, współczynników tarcia, rozkładów wartości ciśnienia w warstwie przyściennej wytworzonej wokół hodowanej tkanki w bioreaktorze w trakcie opływu tej tkanki cieczami biologicznymi o właściwościach lepkosprężystych. Model Rivlina Ericksena lepkosprężystej cieczy biologicznej jest tu brany pod uwagę.
-
Acta of Bioengineering and Biomechanics
Journals -
JOURNAL OF BIOMECHANICS
Journals -
Chosen aspects of muscle biomechanics
PublicationConsidering a striated skeletal muscle as a different properties mechanical system, one can understand series of important phenomena happening in a real muscle phenomenon of muscle: 1) force delivery to skeletal apparatus through tendons; 2) changing of exerted muscle belly mass distribution with regards to skeletal apparatus; 3) beginning drop of muscle force. A disregard of first phenomenon causes an impossibility to explain...
-
Biomechanics of the medial meniscus in the osteoarthritic knee joint
PublicationBackground. Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA...
-
CLINICAL BIOMECHANICS
Journals -
Możliwości modelowania w biomechanice = Modelling capabilities in biomechanics
PublicationOmówiono mozliwości modelowania w biomechanice. Zaprezentowano główne kierunki badań biomechanicznych oraz metody modelowania, w tym najbardziej popularne oprogramowania do symulacji komputerowej modeli biomechanicznych ciała człowieka. Przedstawiono metody wykorzystania programów komputerowych CHARM, SIMM oraz AnyBody System do utworzenia biomechanicznych modeli ramienia człowieka.
-
The Influence of Articular Cartilage Thickness Reduction on Meniscus Biomechanics
PublicationObjective Evaluation of the biomechanical interaction between meniscus and cartilage in medial compartment knee osteoarthritis. Methods The finite element method was used to simulate knee joint contact mechanics. Three knee models were created on the basis of knee geometry from the Open Knee project. We reduced the thickness of medial cartilages in the intact knee model by approximately 50% to obtain a medial knee osteoarthritis...
-
Jaw biomechanics: Estimation of activity of muscles acting at the temporomandibular joint
PublicationThe aim of this study was to elaborate a method of estimation of activity of surface muscles acting at the temporomandibular joint of the healthy subjects by using a surface electromyography (EMG). The scope of this study involved testing chosen jaw motions (open, close, lateral deviation) and process of mastication occurring during eating food with different toughness (chewing gum, cereal and carrot) by using mixed sides, right...
-
International Biomechanics
Journals -
Series on Biomechanics
Journals -
Sports Biomechanics
Journals -
Biomechanics of Lumbar Spine Injury in Road Barrier Collision–Finite Element Study
PublicationLiterature and field data from CIREN database have shown that lumbar spine injuries occur during car crashes. There are multiple hypotheses regarding how they occur; however, there is no biomechanical explanation for these injuries during collisions with road safety barriers (RSBs). Therefore, the objective of this study was to investigate the mechanics of vertebral fractures during car collisions with concrete RSBs. The finite...
-
Biomechanics of the front abdominal wall as a potential factorleading to recurrence with laparoscopic ventral hernia repair
PublicationThis study investigated the front abdominal wallto describe its elasticity in vivo and searched for elongationsthat possibly stretched an implanted mesh, therebycausing fixation failure and subsequent recurrence.To measure front abdominal wall elongations, amodel of fascia movements was created. Eight healthyvolunteers were measured during exercise to determine theextent of elongations in their front abdominal wall. Videoswere...
-
Biomaterials and Biomechanics in Bioengineering
Journals -
Molecular & Cellular Biomechanics
Journals -
JOURNAL OF APPLIED BIOMECHANICS
Journals -
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING
Journals -
Journal of Applied Biomaterials & Biomechanics
Journals -
Biomechanics and Modeling in Mechanobiology
Journals -
Applied Bionics and Biomechanics
Journals -
Russian Journal of Biomechanics
Journals -
Yiyong Shengwu Lixue/Journal of Medical Biomechanics
Journals -
Computer Methods in Biomechanics and Biomedical Engineering-Imaging and Visualization
Journals -
3D model of osteoarthritic (OA) knee joint for analysis of the medial meniscus biomechanics - input text file for computation
Open Research DataThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the OA model thickness of articular cartilage and material parameters of the cartilage and menisci were reduced to simulate degenerative changes in the...
-
3D intact knee model used in analysis of the medial meniscus biomechanics in the osteoarthritic knee joint - input text file for computation
Open Research DataThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model with original geometry and material parametetrs was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. The file was created in Abaqus 6.14-2, but can be read in a text editor.
-
Journal of Mechanical Engineering and Biomechanics
Journals -
EXPERIMENTS AND SIMULATIONS FOR LAPAROSCOPICVENTRAL HERNIA REPAIR IMPROVEMENT
PublicationThe authors conducted a wide experimental and numerical study in order to determine effective approaches in the laparoscopic VH repair. At first the study covered identification of mechanical properties of the abdominal fascia, implants, tacks and transabdominalsutures. Basis on these data, the one and two-dimensional mathematical models were formulated and a number of numerical static and dynamic analyses were carried out. Then...
-
On implementation of fibrous connective tissues’ damage in Abaqus software
PublicationConnective fibrous tissues, such as tendons and ligaments, in humans and animals exhibit hyperelastic behaviour. The constitution of the material of these tissues is anisotropic due to the presence of the collagen fibres, where one family of fibres is the typical case. Traumatic events and/or aging may sometimes lead to the damage of the tissue. The study of motion of affected joints or limbs is usually not permitted in vivo. This...
-
Influence of meniscus shape in the cross sectional plane on the knee contact mechanics
PublicationWe present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with partial and complete radial posterior meniscus root...
-
Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia
PublicationThis paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative...
-
Tensile strength of a weave tendon suture using tendons of different sizes
PublicationThis study compared the maximum load, stress, elongation at failure and the mode of failure of three kinds of tendons most frequently used for tendon grafting and tendon transfers, using the Pulvertaftweave suture.
-
Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublicationAbstrakt artykułu pt. ''Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity''. The paper describes techniques to improve the bioactivity of titanium and ehnahnce the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotubular oxide layer.
-
Preparation of the porous biomaterial based on titanium alloy for orthopaedic implants
PublicationObecnie tytan i jego stopy (Ti-6Al-4V lub Ti-13Nb-13Zr) są szeroko stosowane jako biomateriały dla implantów ortopedycznych. Stale prowadzone są badania nad ich najlepszą odpornością na korozję i zużycie ścierne oraz biozgodnością i bioaktywnością. Obecne badania również skoncentrowane są na projektowaniu, wytwarzaniu i właściwościach materiałów porowatych na podstawie na przykład stopu tytanu (Ti-13Nb-13Zr), które mogą być stosowane...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublicationPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
A Multi Rig Screening Test for Thin Ceramic Coatings in Bio-Tribological Applications
PublicationZaprezentowano metodę badań ogólnej charakterystyki tribologicznej cienkich powłok ceramicznych z wykorzystaniem równoległych testów na wielu stanowiskach o różnej konfiguracji styku powierzchni trących i przy ruchu o różnym charakterze (jednokierunkowym i posuwisto zwrotnym). Przedstawiono wyniki porównania przy pomocy jednoczesnej analizy wyników testów z różnych stanowisk; w wyniku testów uzyskano ranking powłok ze wskazaniem...
-
Degradation of metallic implants
PublicationPresence of metallic implants made of stainless steels, Co and Ti alloys is sometimes followed by some undesired allergic reactions and inflammatory processes and consequently the necessity of reimplantation.
-
Investigation of abdomen surface deformation due to life excitation: implications for implant selection and orientation in laparoscopic ventral hernia repair
PublicationVentral hernia is a common medical problem. Statistically there are around 10% recurrences of the sickness. The authors' former investigation proved edges of the hernia orifice displacements to be one of the factors causing recurrence. Thus, experimental investigation of the abdomen surface deformation due to some normal activities of people is studied.The extreme strains, their localization and directions are identified. The acquired...
-
Influence of laser melting on surface layer properties of titanium alloy Ti6Al4V
PublicationIn time of rapid technology and medicine progress, implants are becoming more widely used in the human body, ranging from dental implants, stabilizing plates, screws, orthopaedic prostheses. For example, there are many types of hip prostheses used for hip replacement as well as various types of materials used for these orthopaedic prostheses. Properties of titanium alloys used in hip prostheses combined with good strength properties,...
-
The early failure of the gamma nail and the dynamic hip screw in femurs with a wide medullary canal. A biomechanical study of intertrochanteric fractures
PublicationBackground: Intertrochanteric fractures may occur in a bone with a wide medullary canal that may lead to significant mobility of a intramedullary nail, contrary to an extramedullary device. This study evaluates the Dynamic Hip Screw and the gamma nail in AO 31.A2.1 fractures in these circumstances. Methods: Synthetic femora with canals drilled to 18 mm were used. Five fixation types were examined: a 2 - hole and a 4 – hole Dynamic...
-
In vivo performance of intraperitoneal onlay mesh after ventral hernia repair
PublicationBackground: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures...
-
Dynamic characteristics of interaperitoneal perfusion.
PublicationPrzedstawiono wyniki badań laboratoryjnych perfuzyjnego przepływu przez model jamy brzusznej człowieka. Szczególną uwagę zwrócono na techniczne aspekty modelu oraz wyników badań. Omówiono technikę pomiarową oraz przeanalizowano rezultaty pod kątem teorii przepływów przez zbiorniki i reaktory.
-
Effect of pulse laser treatment at different process variables on mechanical behavior of carbon nanotubes electrophoretically deposited on titanium alloy
PublicationPurpose: Titanium and its alloys are widely used as biomaterials for long-term implants, but they are usually surface-modified due to their weak bioactivity and wear resistance. Laser processing was used to modify the surface layer, and elemental carbon was a component of the deposited coatings. This research aims to use a combination of both methods based on preliminary electrophoretic deposition of multi-wall carbon nanotubes...
-
Enhancing rheological muscle models with stochastic processes
PublicationPurpose: Biological musculoskeletal systems operate under variable conditions. Muscle stiffness, activation signals, and loads change during each movement. The presence of noise and different harmonic components in force production significantly influences the behaviour of the muscular system. Therefore, it is essential to consider these factors in numerical simulations. Methods: This study aims to develop a rheological mathematical...
-
Modelling and simulation of striated muscle and groups of muscles in arm-forearm system 2D
PublicationModel mięśnia szkieletowego poprzecznie prążkowanego został przedstawiony jako szeregowe połączenie aktywnych i pasywnych odcinków reologicznych. Zasymulowane zostały: skurcze pojedyncze, niecałkowity skurcz tężcowy, całkowity skurcz tężcowy. Model zespołu mięśni w układzie ramię-przedramię opisu-je zmianę kąta obrotu przedramienia względem nieruchomego ramienia. Pobudzając zginacze i prostowniki był zasymulowany obrót przedramienia.
-
Estimation of flow for tissue perfusion of nutrient liquids in bioreactor.
PublicationPrzedstawione zostały problemy związane z wyznaczaniem pola prędkości w warstwie przyściennej opływanej tkanki miękkiej w bioreaktorze. Warunki brzegowe na powierzchni miękkiej tkanki o właściwościach porowatych zostały w niniejszej pracy sformułowane.
-
Analysis of muscles behaviour : The computational model of muscle. -Part I
PublicationW artykule zaproponowano model obliczeniowy mięśnia szkieletowego, który potraktowano jako strukturę o złożonych i zróżnicowanych właściwościach mechanicznych. Szczegółowo opisano metodę identyfikacji tych właściwości. Ponadto określono sposób przeprowadzenia weryfikacji ilościowej i jakościowej zaproponowanego modelu. Za pomocą takiego obliczeniowego modelu mięśnia można łatwo określać siły w mięśniach, które należą do zespołu...
-
Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction
PublicationCementless implants have become widely used for total hip replacement surgery. The long-term stability of these implants is achieved by bone growing around and into the rough surface of the implant, a process called osseointegration. However, debonding of the bone–implant interface can still occur due to aseptic implant loosening and insufficient osseointegration, which may have dramatic consequences. The aim of this work is to...
-
Method for assessing the dynamics and efficiency of diving fins
Publication -
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublicationIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...
-
Application of muscle model to the musculoskeletal modeling
PublicationThe purpose of this paper is to investigate new fusiform muscle models. Each of these models treats a muscle as a system composedof parts characterized by different mechanical properties. These models explain the influence of differences in the stiffness of lateral parts and the degree of muscle model discretization. Each muscle model is described by a system of differential equations and a single integro-differential equation....
-
Tribology of the cartilage cells in the intelligent bioreactor
PublicationW badaniach analityczno-numerycznych wyznaczone zostały pola prędkości przepływu lepkosprężystej, odżywczej nienewtonowskiej cieczy biologicznej, a także powstające siły tarcia w trakcie hodowli w warstwie granicznej wokoło powierzchni hodowanych komórek w bioreaktorach, stawach człowieka oraz w szczelinach mikrołożysk. Dodatkowo rozpatrywane będą przepływy potencjalne płynu stawowego z jamy stawowej, które odżywiają chrząstkę...
-
Hydrodynamic pressure in micro-and nano bearing gap
Publication.
-
Influence of geometry and annealing temperature in argon atmosphere of TiO2 nanotubes on their electrochemical properties
Publication -
Analysis of muscles behaviour. Part II. The computational model of muscles group acting on the elbow joint
PublicationThe purpose of this paper is to present the computational model of muscles' group describing the movements of flexion/extension at the elbow joint in the sagittal plane of the body when the forearm is being kept in the fixed state of supination/pronation. The method ofevaluating the muscle forces is discussed in detail. This method is the basis for the quantitative and qualitative verification of the proposed computational model...
-
Deposition of phosphate coatings on titanium within scaffold structure
PublicationPurpose: Existing knowledge about the appearance, thickness, and chemical composition of phosphate coatings on titanium inside porous structures is insufficient. Such knowledge is important for the design and fabrication of porous implants. Methods: Metallic scaffolds were fabricated by selective laser melting of 316L stainless steel powder. Phosphate coatings were deposited on Ti sensors placed either outside the scaffolds or...
-
The effective elastic properties of human trabecular bone may be approximated using micro-finite element analyses of embedded volume elements.
PublicationBoundary conditions (BCs) and sample size affect the measured elastic properties of cancellous bone. Samples too small to be representative appear stiffer under kinematic uniform BCs (KUBCs) than under periodicity-compatible mixed uniform BCs (PMUBCs). To avoid those effects, we propose to determine the effective properties of trabecular bone using an embedded configuration. Cubic samples of various sizes (2.63, 5.29, 7.96, 10.58...
-
Mechanical behaviour of knit synthetic mesh used in hernia surgery
PublicationPurpose: There is a discussion in literature concerning mechanical properties and modelling of surgical meshes. An important feature of elastic modulus dependency on load history is taken into account in this paper, as implants are subjected to variable loading during human activity. The example of DynaMesh®-IPOM surgical implant is studied. Methods: The analysis is based on failure tension tests and cyclic loading and unloading...
-
Mechanical and structural investigations of wings of selected insect species
PublicationThis paper presents research and measurements leading to obtaining the Young’s modulus of wing bearing structures of selected insect species. A small testing machine intended for three-point bending and equipped with instruments registering low forces was constructed for the needs of the experiment. The machine was used to perform numerous bending tests of wings of three species of insects (obtained from a breeding farm): Attacus...
-
Validation of Hydraulic Mechanism during Blowout Trauma of Human Orbit Depending on the Method of Load Application
PublicationThe more we know about mechanisms of the human orbital blowout type of trauma, the better we will be able to prevent them in the future. As long as the buckling mechanism’s veracity is not in doubt, the hydraulic mechanism is not based on equally strong premises. To investigate the correctness of the hydraulic mechanism’s theory, two different methods of implementation of the hydraulic load to the finite element method (FEM) model...
-
The Influence of External Additional Loading on the Muscle Activity and Ground Reaction Forces during Gait
PublicationAsymmetrical external loading acting on the usculoskeletal system is generally considered unhealthy. Despite this knowledge, carrying loads in an asymmetrical manner like carrying on one shoulder, with one hand, or on the strap across the torso is a common practice. This study is aimed at presenting the effects of the mentioned load carrying methods on muscle activity assessed by using thermal field and ground reaction forces....
-
Biological and mechanical properties of bone cement with nanoarticles - in vitro and in vivo research
PublicationDespite antibiotic preventive treatment both before and after implant implementation, the risks of infection are real. These infections develop at the implant surface a few months after inserting them into the body. To prevent the development of bacteria and reduce the risk of infection, implants coated with nanoparticles are used. The Mechanical Department of the Technical University of Gdansk carries out research into using bone...
-
Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation
Publicationrelation to the different range of typical deformations observed in different directions and zones of abdomen surface due to the patients’ life activities, has a significant influence on the extreme junction forces in the mesh–tissue connections and hence the repair persistence. The finite element model of the orthotropic implant was developed, and the junction forces in the connections of tissue and mesh were studied. The kinematical...
-
Mechanical properties of mosquito nets in the context of hernia repair
PublicationThe paper deals with issue of applying mosquito nets as implants in hernia repair, which have already been used in resource-poor developing countries. Uniaxial tensile tests have been conducted on polyester mosquito meshes in two orthogonal directions. Non-linear elastic constitutive laws parameters have been identified to be applied in dense net material models. Mechanical performance of tested mosquito nets has been compared...
-
Mathematical modelling of implant in an operated hernia for estimation of the repair persistence
PublicationThis paper presents mathematical modelling of an implanted surgical mesh used in the repair process of the abdominal hernia. The synthetic implant is simulated by a membrane structure. The author provides a material modelling of the implant based on the dense net model appropriate for technical fabrics. The accuracy of the proposed solution is evaluated by comparing the simulations of the dynamic behaviour of the system with the...
-
Influence of energy absorbers on Malgaigne fracture mechanism in lumbar-pelvic system under vertical impact load
Publication -
Two-criteria optimisation problem for ventral hernia repair
PublicationTwo-criteria optimisation problem related to laparoscopic ventral hernia repair is formulated in this paper. An optimal implant from a given set and its orientation is sought. The implant is subjected to kinematic extortions due to a patient’s body movement and intra-abdominal pressure. The first criterion of the optimisation problem deals with the reaction force in the implant fastener, while the deflection of the implant constitutes...
-
Combined numerical and experimental approach to determine numerical model of abdominal scaffold
PublicationA proper junction of the prosthesis and the abdominal wall is important in successful hernia repair. The number of tacks should be balanced to assure appropriate mesh fixation and not to induce post-operative pain. Numerical simulations help to find this balance. The study is aimed at creating a proper numerical model of a knitted surgical mesh subjected to boundary conditions and load occurring in the abdominal cavity. Continuous,...
-
Wiktoria Wojnicz dr hab. inż.
PeopleDSc in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2019 PhD in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2009 (with distinction) List of papers (2009 - ) Wojnicz W., Wittbrodt E., Analysis of muscles' behaviour. Part I. The computational model of muscle. Acta of Bioengineering and Biomechanics, Vol. 11, No.4, 2009, s. 15-21 Wojnicz W., Wittbrodt E., Analysis of...
-
Czesław Kazimierz Szymczak prof. dr hab. inż.
People -
Leszek Dąbrowski dr inż.
PeopleLeszek Dabrowski Senior Lecturer in the Chair of Machine Design and Automotive Engineering in the Department of Mechanical Engineering. He graduated in 1985 and obtained PhD in mechanical engineering, specializing in the field of tribology in 1997. His scientifical interests also include computational methods in engineering, biomechanics, medical engineering. His recent work focuses on the use of CT data in FEM and its application...
-
Katarzyna Szepietowska dr inż.
People -
Validation of lumbar spine finite element model
Open Research DataThe functional biomechanics of the lumbar spine have been better understood by finite element method (FEM) simulations. However, there are still areas where the behavior of soft tissues can be better modeled or described in a different way. The purpose of this research is to develop and validate a lumbar spine section intended for biomechanical research....
-
Biomechanika,Wykład,IMM,letni 2023-2024 (PG_00055757)
e-Learning CoursesCelem przedmiotu jest uzyskanie wiedzy z biomechaniki ciała człowieka.The aim of this subject is to acquire knowledge about the human body biomechanics.
-
Biomechanika,Wykład,IM,IMSiB,letni 2023-2024(PG_00048715)
e-Learning CoursesCelem przedmiotu jest uzyskanie wiedzy z biomechaniki ciała człowieka.The aim of this subject is to acquire knowledge about the human body biomechanics.
-
Robotics for human health and performance 03.2022
e-Learning CoursesThis course is to provide knowledge in area of biomechanics, necessary to design instrumentation for human health and performance, and automatics necessary to design simple instrumentation as well as about human-robot interface.
-
Krzysztof Jan Kaliński prof. dr hab. inż.
PeopleKrzysztof J. Kaliński completed his MSc study at Gdańsk University of Technology (GUT) Faculty of Production Engineering (1980, result – get a first). He obtained PhD at GUT Faculty of Machine Building (1988, result – get a first), DSc at GUT Faculty of Mechanical Engineering (ME) (2002, result – get a first), and professor’s title – w 2013 r. In 2015 r. he became full professor.His research area includes: theoretical and applied...
-
Surface and interfacial anti-plane waves in micropolar solids with surface energy
PublicationIn this work, the propagation behaviour of a surface wave in a micropolar elastic half-space with surface strain and kinetic energies localized at the surface and the propagation behaviour of an interfacial anti-plane wave between two micropolar elastic half-spaces with interfacial strain and kinetic energies localized at the interface have been studied. The Gurtin–Murdoch model has been adopted for surface and interfacial elasticity....
-
A significance of multi slip condition for inclined MHD nano-fluid flow with non linear thermal radiations, Dufuor and Sorrot, and chemically reactive bio-convection effect
PublicationThe aim of this research is to discuss the significance of slip conditions for magnetized nanofluid flow with the impact of nonlinear thermal radiations, activation energy, inclined MHD, sorrot and dufour, and gyrotactic micro motile organisms over continuous stretching of a two-dimensional sheet. The governing equations emerge in the form of partial differential equations. Since the resultant governing differential equations...
-
Cost-Effective and Sufficiently Precise Integration Method Adapted to the FEM Calculations of Bone Tissue
PublicationThe technique of Young’s modulus variation in the finite element is not spread in biomechanics. Our future goal is to adapt this technique to bone tissue strength calculations. The aim of this paper is to present the necessary studies of the element’s integration method that takes into account changes in material properties. For research purposes, a virtual sample with the size and distribution of mechanical properties similar...
-
The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion
PublicationObjective The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. Methods One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then...
-
Numerical Model of Femur Part
PublicationThe aim of the study is to create a new more accurate method of femur part modelling by using the finite element method. According to this new method, a femur part is treated as a complex structure composed of trabecular bone (internal part) and cortical bone (external part). The internal part is modelled as a scaffold, thus the external part is modelled as a coat (i.e. covering). Applying the programme ABAQUS, there were created...
-
Development and validation of lumbar spine finite element model
PublicationThe functional biomechanics of the lumbar spine have been better understood by finite element method (FEM) simulations. However, there are still areas where the behavior of soft tissues can be better modeled or described in a different way. The purpose of this research is to develop and validate a lumbar spine section intended for biomechanical research. A FE model of the 50th percentile adult male (AM) Total Human Model for Safety...
-
Numerical analysis of lumbar spine injury during road safety barrier collision
PublicationPurpose: Enhancing road safety is a critical goal worldwide, necessitating the development of clear standards for road safety systems. This study focuses on lumbar spine (L-spine) compression injuries during collisions with concrete road safety barriers (RSBs). It aims to analyze internal forces during impact to understand L-spine injury biomechanics in such accidents. Methods: The research included a literature review, analyzing...
-
Krzysztof Żerdzicki dr inż.
People -
Mechanical response of human thoracic spine ligaments under quasi-static loading: An experimental study
PublicationPurpose This study aimed to investigate the geometrical and mechanical properties of human thoracic spine ligaments subjected to uniaxial quasi-static tensile test. Methods Four human thoracic spines, obtained through a body donation program, were utilized for the study. The anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), capsular ligament (CL), ligamenta flava (LF), and the interspinous ligament and...
-
BJS-03 DO WE NEED FIXATION OF THE MESH IN LAPAROENDOSCOPIC TECHNIQUES FOR M3 INGUINAL DEFECTS? AN EXPERIMENTAL STUDY
PublicationThe authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. The results showed that mesh fixation is not the only alternative to preventing recurrence in complex defects and that the type of implant seems to be a key factor from the point of view of mechanics and biophysics.
-
Static and dynamic modelling blow- out type trauma of orbital wall
PublicationAuthors of the paper present initial results of finite element analysis of a blow-out type trauma of orbital wall. The research is liked with laboratory tests for the Young’s modulus of bones evaluation. In the finite element analysis the neighbourhood of orbital wall is modelled by triangle thin shell finite elements. In the paper results of nonlinear static and transient dynamic analysis (including damping) are compared. The...
-
Posttraumatic Orbital Emphysema: A Numerical Model
PublicationOrbital emphysema is a common symptom accompanying orbital fracture. The pathomechanism is still not recognized and the usually assumed cause, elevated pressure in the upper airways connected with sneezing or coughing, does not always contribute to the occurrence of this type of fracture. Observations based on the finite model (simulating blowout type fracture) of the deformations of the inferior orbital wall after a strike in...
-
SIMULATION OF PROCEED® SURGICAL MESH APPLIED TO VENTRAL HERNIA REPAIR
PublicationIn the present research, Proceed® implant is considered. The system is subjected to short-time dynamic pressure load, similar to post-operative cough naturally occurring in human abdomen. The model refers to a clinical case of 5cm of hernia operated by Proceed implant fixed by 15 joints every 3cm around the orifice. The simulations of the implanted mesh are performed by means of the Finite Element Method. The implant is modelled...
-
Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair
PublicationEven though the incisional hernia repair surgery is a well known procedure, mechanical properties of the tissue-implant system are unknown so the implantation of the repairing mesh is quite intuitive and, recurrences of the illness still take place. The main objective of the study is to define an operated hernia model that can be used for surgery planning and the assessment of the repair persistence. The load applied to the structure...
-
IMPLANT USED IN HERNIA REPAIR UNDER PHYSIOLOGICAL MOVEMENTS OF HUMAN ABDOMEN
PublicationThe study deals with the mechanical behaviour of implant used in repair of abdominal hernia. The influence of orientation of the orthotropic implants in different areas of abdominal wall is studied.
-
Surface sliding in human abdominal wall numerical models: Comparison of single-surface and multi-surface composites
PublicationDetermining mechanical properties of abdominal soft tissues requires a coupled experimental-numerical study, but first an appropriate numerical model needs to be built. Precise modeling of human abdominal wall mechanics is difficult because of its complicated multi-layer composition and large variation between specimens. There are several approaches concerning simplification of numerical models, but it is unclear how far one could...
-
A PRELIMINARY STUDY ON THE OPTIMAL CHOICE OF AN IMPLANT AND ITS ORIENTATION IN VENTRAL HERNIA REPAIR
PublicationThis paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic...
-
Destruction of shell structures under the dynamic load on the human skull trauma basis
PublicationThe main aim of this work is to investigate patterns of potential orbital bone fractures due to mechanical injuries. The solution of the main problem is followed by analysis of several testing examples having straight correlation with civil engineering structures, in which materials of wide range of stiffness are applied. To solve the main problem, the three-dimensional finite element method (FEM) model of the orbital region has...
-
ReFlexeNN - the Wearable EMG Interface with Neural Network Based Gesture Classification
PublicationThe electromyographic activity of muscles was measured using a wireless biofeedback device. The aim of the study was to examine the possibility of creating an automatic muscle tension classifier. Several measurement series were conducted and the participant performed simple physical exercises - forcing the muscle to increase its activity accordingly to the selected scale. A small wireless device was attached to the electrodes placed...
-
A Biofeedback System that Uses the Game to Study Electrical Muscle Activity
PublicationThe aim of this project was to design a system that will allow performing repetitive muscle exercises using a biofeedback device. It is supposed to enhance the motivation and attractiveness of the performed tasks thanks to an interactive game developed for mobile devices with the Android operating system. The built-in calibration mechanisms enable the users to play a game that is independent of their abilities which evens out the...
-
Upper Limb Bionic Orthoses: General Overview and Forecasting Changes
PublicationUsing robotics in modern medicine is slowly becoming a common practice. However, there are still important life science fields which are currently devoid of such advanced technology. A noteworthy example of a life sciences field which would benefit from process automation and advanced robotic technology is rehabilitation of the upper limb with the use of an orthosis. Here, we present the state-of-the-art and prospects for development...
-
Test Stand for Multi-option Stretching of Soft Tissues
PublicationThe paper presents the genesis of the design and possibilities of the test stand for stretching soft tissues as well as examples of tests carried out on this device.
-
Tomasz Wiczenbach mgr inż.
People