Search results for: medical diagnostics
-
Experimental guinea pig model of dermatophytosis: a simple and useful tool for the evaluation of new diagnostics and antifungals
PublicationCelem badań było opracowanie prostego modelu zwierzęcego (świnki morskie) odpowiedniego do sprawdzania systemów diagnostycznych oraz terapii infekcji dermatofitów. Następujące zmienne były analizowane: przygotowanie skóry przez golenie versus użycie taśmy, testowy szczep Microsporum canis czy Trichophyton mentagrophytes jako czynnik etiologiczny, sposób inokulacji. Przebieg infekcji był oceniany poprzez ocenę zaczerwienienia i...
-
Chemiluminogenic acridinium salts: A comparison study. Detection of intermediate entities appearing upon light generation
PublicationThe nine derivatives of acridine-9-carboxylic acid (CMADs) capable for chemiluminescence (CL), representing various classes of compounds were isolated in a chemically pure state (assessed by RP-HPLC) and identified using high resolution mass spectrometry (ESI-QTOF) and magnetic resonance (1H NMR) techniques. Among them are aryl acridinium esters, containing certainly selected and located substituents in both aromatic systems, an...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Framework for extracting rails and setting-out railway line axis based on UAV photogrammetric measurements
Open Research DataTechnical diagnostics enables assessing the current technical condition of a railway line and adjacent infrastructure, and to forecast its changes over a specific time horizon. One of its elements is the periodic monitoring of rail position and their geometry. The data set presents a new framework for the setting-out of a railway track axis. The process...
-
Silicon microcantilever with impedance sensor
Open Research DataThe issue of microelectromechanical systems (MEMS) [1] has been enjoying popularity and interest since the 90s of the 20th century. Microcells are one of the simplest devices of this type, but they can be widely used in sensors. There are reports on the possibility of using this type of sensors in the context of such important issues as diagnostics...
-
Instantaneous power signal measurements for bearing diagnostics
Open Research DataBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
AeroSense Measurements: Wind Tunnel EPFL
Open Research DataData from wind tunnel tests of Aerosesne measurement system installed on NACA63418 at EPFL wind tunnel.
-
Finite element models used in diagnostics of transverse cracks in bridge approach pavement
Open Research DataTransverse cracks in the asphalt pavement were observed on bridge structures next to single-module expansion joints with a 5 meter approach slab set at the depth of 1 m. The finite element (FE) models of the approach pavement were created to investigate the reasons of premature cracking and crack initiation mechanism over the back edge of the abutment...
-
Agnieszka Mikołajczyk-Bareła dr inż.
People -
Optoelectronic device for hematocrit measurements
PublicationAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
DIFFRACTION PHASE MICROSCOPY FOR OBSERVATION ON RED BLOOD CELLS FLUCTUATION
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – RBCs (Red Blood Cells). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations observation...
-
Observation on red blood cells fluctuations by diffraction phase microscopy
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – Red Blood Cells (RBCs). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations...