Filters
total: 1914
filtered: 378
-
Catalog
Chosen catalog filters
Search results for: abandonment ratio
-
The level of VAT in relation to the GDP of selected European Union countries in 2007-2015 (in%)
Open Research DataVAT (Value Added Tax) is part of a strictly harmonized tax within the European Union. Under the so-called The Sixth Directive introduced provisions regulating the subject and subject of taxation, tax exemptions and exclusions as well as the tax collection mechanism in all Member States.
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=2.1, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.1, b=0.14) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=2.1, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.1, b=0.14) and (C=5.5, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=5.5, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=2.0, b=0.11) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=2.1, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=5.5, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=2.0, b=0.11) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=5.5, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=2.8, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=5.30, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.20, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.40, b=0.45) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.40, b=0.45) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Instantaneous power signal measurements for bearing diagnostics
Open Research DataBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
The profiles and spectrum of aqua solution of tannic acid by HPLC-DAD-MS analysis.
Open Research DataThe profiling of tannic acid is determined by examining the content and proportion / ratio of gallotannins [Aras et al. 2016, Clifford et al. 2007, Gauri et al. 2012, Nishizawa et al. 1982]. In order to check the ion mass distribution (TIC) in an aqueous solution of commercial tannic acid, a direct sample injection (TA) was performed into the mass spectrometer....
-
XPS analysis of TBBO glass
Open Research DataGlasses and glass-ceramics with nominal composition 73 TeO2– 4BaO– 3Bi2O3–18SrF2-2RE2O3 (where RE = Eu, Dy) have been synthesized by conventional melt-quenching technique and subsequent heat treatment at 370 °C for 24 h in air atmosphere. Various Eu3+ to Dy3+ molar ratio have been applied to investigate luminescence properties in both glass and glass-ceramic...
-
XRD, DTA and luminescence measurements of B2O3-Bi2O3-AlF3 glasses doped with Eu3+, Tb3+ and Tm3+ ions
Open Research DataThe DataSet contains the XRD,DTA and luminescence measurements for the B2O3-Bi2O3-AlF3 glass system. Samples were prepared by the conventional melt quenching technique. Starting materials were melted in porcelain crucibles at 950 oC for 20 min. XRD and DTA data were collected for 50B2O3-50Bi2O3,45B2O3-45Bi2O3+10AlF3 and 40B2O3-40Bi2O3+20AlF3 glasses....
-
Change of catalytic parameters for SOFC fueled by H2 and biogas mixture at 750 C
Open Research DataThe dataset contains the Change of catalytic parameters for SOFC fueled by H2 and biogas mixture at 750 C (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit. The parameters are conversion rates, selectivities and yields of products
-
The electrical properties mesurements of SOFC with Ce0.9Cu0.1O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.9Cu0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
Phylogenetic analysis of Oncidieae subtribe - matK plastid region
Open Research DataThe dataset contains alignment and consensus matrix files, and results of phylogenetic analysis of plastid matK region from 186 orchid species considered to belong Oncidieae subtribe. Sequences were assessed from NCBI GeneBank (list of all records with identifiers in the separate file)
-
The electrical properties mesurements of SOFC with Ce0.9Co0.1O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.9Co0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of SOFC with Ce0.8Co0.1Cu0.1O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.8Co0.1Cu0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of SOFC with Ce0.8Co0.15Cu0.05O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.8Co0.15Cu0.05O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
Phylogenetic analysis of Oncidieae subtribe - ITS1-5,8S-ITS2
Open Research DataThe dataset contains alignment and consensus matrix files, and results of phylogenetic analysis of ITS1- 5,8S-ITS2 region from 186 orchid species considered to belong Oncidieae subtribe. Sequences were assessed from NCBI GeneBank (list of all records with identifiers in the separate file)
-
SEM images of Mo2Ga2C MAX material
Open Research DataIn the dataset, are included SEM images of molybdenum gallium carbide MAX materials.
-
SEM micrographs of diamond-phase (sp3-C) rich boron-doped carbon nanowalls (sp2-C)
Open Research DataThis dataset contains the Scanning Electron Microscopy (SEM) micrographs taken for rich boron-doped carbon nanowalls structures, with different boron addition during the synthesis process and different CVD synthesis duration. The [B]/[C] ratios in the plasma were set to 0k, 1.2k, 2k and 5k ppm. The time of growth was ranging between 4 and 9 hours. This...
-
Data for meta-analysis on interversions reducing car use
Open Research DataThis dataset contains the results of a meta-analysis of reported interventions reducing car use. To standardise intervention effects reported in different scales, the Hedges’ g effect size measure was used (ratio of raw difference in samples’ means and pooled standard deviation). The standardised studies outcomes, along with overall outcome, were...
-
The electrochemical studies of thin boron-doped diamond films deposited at conductive poly(lactic acid) 3D prints
Open Research DataThe dataset contains the electrochemical characteristics of the electrodes composed of thin boron-doped diamond films coated on commercially available graphene-doped polylactide acid. The boron doping level expressed as the [B]/[C] ratio in the gas phase for these studies was 500 and 10,000 ppm.
-
The Rayleigh model of the multipath fading channel
Open Research DataThe dataset contains the results of simulations that are part of the research on modelling the multipath fading in the communication channel. The Rayleigh fading envelope is generated using the Monte-Carlo simulation (MCS) in the LabVIEW programming environment.
-
Nonlinear impedance of as-quenched Bi2VO5.5 glass-ceramic was measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrical properties of as-quenched Bi2VO5.5 glass-ceramic was measured by impedance spectroscopy method.