Filters
total: 4155
filtered: 3080
-
Catalog
- Publications 3080 available results
- Journals 328 available results
- Conferences 2 available results
- Publishing Houses 1 available results
- People 190 available results
- Projects 1 available results
- e-Learning Courses 30 available results
- Events 2 available results
- Open Research Data 521 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: CURRENT CONVEYOR
-
Current molecular methods for the detection of hepatitis B virus quasispecies
Publication -
Current rectification in molecular junctions produced by local potential fields
Publication -
Ionic transport in silica xerogels investigated by dynamic current voltagecharacteristics.
PublicationPodano wstępne rezultaty badania transportu ujemnych jonów w kserożelach Si02 w warunkach wysokiego gradientu temperatury w próbce, wywołanego jej ekstremalnie niską przewodnością cieplną. Uzyskane charakterystyki pozostają w zgodzie z przewidywaniami teoretycznymi. Na ich podstawie określono znak jonów, ich ruchliwość i energię aktywacji.
-
Measurements and Analysis of Motor Supplying Current Waveform for Diagnostic Purposes
PublicationPodano proponowaną metodę diagnostyki łożysk tocznych w silnikach indukcyjnych poprzez pomiar i analizę prądu zasilającego. Przedstawiono opracowany system pomiarowy oraz wyniki badań na łożyskach o specjalnie wprowadzonych uszkodzeniach.
-
A new method of current limitation. Nowa metoda ograniczania prądu.
PublicationZaprezentowano nowa ideę hybrydowego, bezstykowego ogranicznika prądów zwarciowych oraz możliwości jego aplikacji. W ograniczniku tym zastąpiono łącznik zestykowy bezpiecznikiem o ultra krótkim topiku, dzięki czemu uniknięto niedogodności związanych z napędem występujących w klasycznych łącznikach hybrydowych. Rolą bezpiecznika w tym nowym zestawie jest wyłącznie zadziałanie w warunkach zwarciowych, a po przejęciu prądu...
-
Dark current characteristics of single crystalline silicon solar cells.
PublicationW pracy przedstawiono wpływ szkodliwych rezystancji na parametry pracy krzemowych ogniw fotowoltaicznych. W tym celu wyznaczono ciemne charakterystyki prądowo-napięciowe. W celu opisu własności elektrycznych ogniw zastosowano model jedno- i dwu-diodowy. Wyznaczono współczynniki nieidealności charakterystyki i rezystancję szeregową w całym zakresie temperatur pracy ogniw fotowoltaicznych dla zastosowań naziemnych. Wyznaczona za...
-
Advanced current regulated PWM inverter with simplified load model.
PublicationW artykule przedstawionio nowy regulator prądu stojana silnika asynchronicznego zasilanego z falownika napięcia. Regulator wykorzystuje obliczenia siły elektromotorycznej silnika. Rozważonio wpływ zmian parametrów silnika na działanie regulatora. Wykorzystano uproszczony model silnika bez uwzględnienienia rezystancji stojana. Zastosowano stałą częstotliwość próbkowania prądu. Układ zrealizowania w programie symulacyjnym oraz na...
-
Comparision of the current-mode backprojection and Jacobian-based reconstruction algorithms.
PublicationW pracy przedstawiono wynik porównania jakości dwóch algorytmów, pierwszego opartego na pomiarze rozpływu prądu pomiędzy elektrody pomiarowe i algorytmu wykorzystującego informację zawartą w Jakobianie. Porównano szybkość i dokładność tych algorytmów. Wskazano na dużą szybkość pierwszego i znacznie lepszą jakość drugiego algorytmu.
-
Mechatronic design for improve current performences of machines : Chapter 3
PublicationPrzedstawiono wybrane zagadnienia z zakresu projektowania mechatronicznego w zastosowaniu do maszyn służących do transpoetu wibracyjnego w procesie suszenia i do przecinarek ściernicowych. Opisano układy sterowania i optymalizację parametrów technologicznych.
-
Thermally affected parameters of the current-voltage characteristics of silicon photocell
PublicationW pracy wykazano: zależność wzrostu prądu zwarcia wskutek absorpcji dodatkowych fotonów ze wzrostem temperatury, spadek napięcia wbudowanego złącza p-n wraz ze wzrostem temperatury, wpływ temperatury na zmianę napięcia otwartego obwodu. Dodatkowo wyznaczone odpowiednie współczynniki temperaturowe porównano z wartościami wynikającymi z rozważań teoretycznych. Badano parametry elektryczne następujących elementów wykonanych z amorficznego...
-
Measuring system for analysis of motor supplying current for diagnostic purposes
PublicationProblemy, jakie pojawiają się przy interpretacji wyników pomiarów prądu silnika dla celów diagnostycznych wynikają z różnicy częstotliwości składowych obliczonych teoretycznie i uzyskanych w badaniach eksperymentalnych. W przedstawionym systemie pomiarowym problem ten rozwiązano w ten sposób, że pomiar częstotliwości sieci zasilającej i prędkości obrotowej jest wykonywany w tym samym przedziale czasowym, co pomiar składowych widma.
-
Application of residual current devices in electrical installations with frequency converters
PublicationW instalacjach elektrycznych, w których znajdują się przemienniki częstotliwości mogą pojawić się prądy zwarcia doziemnego o różnej częstotliwości lub stałe. Większość wyłączników różnicowoprądowych nie reaguje na tego typu prądy, co powoduje, że ochrona przeciwporażeniowa jest nieskuteczna. W obwodach z przemiennikami częstotliwości mogą pojawiać się przejściowe i ustalone prądy upływowe o znacznych wartościach. Prądy te znacząco...
-
New Methods of Short-Circuit Current Limiting and Switching-off
PublicationPrzedstawiono wyniki badań symulacyjnych i eksperymentalnych hybrydowych indukcyjno-tyrystorowych ograniczników i wyłączników prądu zwarciowego. Impedancja dławika ogranicznika prądu jest wtrącana do obwodu zwarciowego dopiero w chwili, gdy prąd zwarciowy przekroczy wartość prądu wymuszonego w dławiku przez zewnętrzne źródło prądu. Ograniczanie dynamiki prądu zwarciowego jest bezzwłoczne. Układ nie generuje przepięć łączeniowych....
-
Hybrid inductance-thyristor short-circuit current limiting devices
PublicationDla wartości prądu w gałęzi w której zainstalowane jest urządzenie jest mniejsza od prądu w dławiku urządzenia, dławik jest zwarty gałęzią z tyrystorem. Impedancja bieguna urządzenia hybrydowego jest praktycznie równa zero. W chwili wzrostu prądu w gałęzi z urządzeniem ograniczającym ponad tę wartość, do obwodu głównego wtrącona zostaje impedancja kolejno dwóch dławików, ograniczając bezzwłocznie dynamikę i amplitudę prądu zwarciowego....
-
Excitonic stimulation of current flowing along thin tetracene layer
PublicationW pracy badane były prądy będące wynikiem oddziaływania ekscytonów tripletowych ze spułapkowanymi nośnikami ładunku w warstwach tetracenu. Badane próbki oświetlane były od strony podłoża oraz od strony przeciwległej podłożu.
-
Oxylipin profiling for clinical research: Current status and future perspectives
PublicationOxylipins are potent lipid mediators with increasing interest in clinical research. They are usually measured in systemic circulation and can provide a wealth of information regarding key biological processes such as inflammation, vascular tone, or blood coagulation. Although procedures still require harmonization to generate comparable oxylipin datasets, performing comprehensive profiling of circulating oxylipins in large studies...
-
Case Study of Stray Current Corrosion of Tall Ship Mast
PublicationNowadays, in the present technical civilization there are numerous complex technical systems that may generate various hazards. Large transport units like ships can be considered as the most dangerous systems. Therefore, it is important to eliminate all possible hazards, especially for ship crewmembers. Destruction of ship structural components caused by vast corrosion is one of these hazards. Usually, its activity leads to a decrease...
-
3D scanning system for railway current collector contact strips
PublicationUndisturbed collection of current from a contact wire of the catenary constitutes one of the basic elements in reliable operation of electrified rail transport, particularly when vehicles move at high speed. Quality of current collection is influenced by the construction of catenary and current collectors, as well as by the technical condition and regulation of these two elements. Total contact force of a current collector head...
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublicationMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Sensorless Control of Induction Machine Supplied by Current Source Inverter
PublicationThe paper describes the voltage control technique of induction machines supplied by a current source inverter. The control system is based on proposed new multi-scalar variables, which are named “r.” The control system contains the output filter capacitor's model. In the sensorless control system the Z type backstepping speed observer was applied. The mathematical dependences are confirmed by simulation and experimental research.
-
Speed sensorless induction motor drive with predictive current controller
PublicationToday, speed sensorless modes of operation are becoming standard solutions in the area of electric drives. This paper presents a speed sensorless control system of an induction motor with a predictive current controller. A closed-loop estimation system with robustness against motor parameter variation is used for the control approach. The proposed algorithm has been implemented using field-programmable gate arrays (FPGAs) and a...
-
Sensorless Control of Induction Motor Supplied by Current Source Inverter
Publication -
Errors of a Linear Current Approximation in High-Speed PMSM Drives
PublicationCurrent sampling techniques and predictive algorithms used in the digital control of electric drives rely on a simple mathematical model that assumes linear current changes upon constant supplying voltages. This paper identifies rotor movement as a factor that makes this assumption invalid when the rotor covers an angular distance of a few tens of degrees during the control interval duration. The errors of the linear current approximation...
-
CURRENT TRENDS IN RECYCLING OF PHOTOVOLTAIC SOLAR CELLS AND MODULES WASTE
PublicationIn comparison to other energy producing techniques, photovoltaics (PV) is one of the most promising options: no emission of any matter into the environment during operation; extremely long operation period (estimated average: 25 years), minimum maintenance, robust technique, aesthetic aspects. The use of photovoltaics is rapidly increasing, and the respective market is developing accordingly. Although PV manufacturing equipment...
-
Determination of Local Corrosion Current from Individual Harmonic Components
PublicationHarmonic analysis has been used in corrosion measurements for several decades. During this period the method has been refined and developed. Nevertheless, the technique has not been applied to properties determination in local scale yet. This paper is focused on local corrosion current measurements based on harmonic analysis. For this purpose, a non-linear nature of electrode processes is used and measured in local scale applying...
-
Mainstream shortcut N removal modeling current status and perspectives
PublicationThis work gives an overview of the state-of-the-art in modelling of short-cut processes for nitrogen removal in mainstream wastewater treatment and presents future perspectives for directing research efforts in line with the needs of practice. The modelling status for deammonification (i.e., anammox-based) and nitrite-shunt processes is presented with its challenges and limitations. The importance of mathematical models for considering...
-
Modal analysis of railway current collectors using Autodesk Inventor
PublicationThe paper presents the results of modal analysis of railway current collector type 160EC. In the first place, the analysis was carried out analytically for a simplified two lumped mass pantograph model. Then numerical analysis was conducted in the Autodesk Inventor (AI) on the prepared multibody model using the AI modal analysis algorithm, which is based on the finite element method (FEM). Model elements which are most relevant...
-
Determining the leakage current resistive component by the orthogonal vector method
PublicationThe measurement of the metal – oxide surge arresters (MOSA) leakage current and the analysis of its components is a key diagnostic criterion according to technical standards. During on site MOSA condition assessment, the easy way is based on the measurement only leakage current, without the inconvenient live working measurements of supply voltage. Orthogonal vectors method of determination the resistive leakage current is presented....
-
Remarks on the Subject of Back-Up Protection of Residual Current Devices
PublicationResidual current devices without integral overcurrent protection (RCCBs) are back-up protected by fuses or miniature circuit-breakers (MCBs). If the latter are used, special attention must be given to the coordination between an RCCB and an MCB. This paper indicates probable cases of the aforementioned devices coordination, in which back-up protection of the RCCB is not adequate. A laboratory test has shown that depending on the...
-
Time-current tripping curves of arc fault detection devices
PublicationTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Security of Cryptocurrencies: A View on the State-of-the-Art Research and Current Developments
Publication[Context] The goal of security is to protect digital assets, devices, and services from being disrupted, exploited or stolen by unauthorized users. It is also about having reliable information available at the right time. [Motivation] Since the inception in 2009 of the first cryptocurrency, few studies have been undertaken to analyze and review the state-of-the-art research and current developments with respect to the security...
-
IPMSM rotor position estimator based on analysis of phase current derivatives
PublicationThis paper describes an algorithm for estimation of IPMSM angular rotor position. The algorithm uses derivatives of motor phase currents resulting from PWM modulation to obtain the rotor position. The presented method is designed for medium- and high-speed range, since it is based on determination of the EMF vector. Algorithm is characterised by a very simple formulae. The calculation of rotor position is performed in every PWM...
-
Analysis of Factors Having an Influence on Current in Non-Linear Inductive Brunch
PublicationArtykuł prezentuje analityczny opis pršdu włšczania nieliniowej gałęzi indukcyjnej. Analizę przeprowadzono w oparciu o odcinkowo-liniowš aproksymację charakterystyki magnesowania. Przeanalizowano wpływ chwili właczenia napięcia, charakteru obwodu i magnetyzmu szczštkowego rdzenia na przebieg i wartoć maksymalnš pršdu.
-
Performance improvement method for the voltage-fed qZSI with continuous input current
Publication -
Bearing current path and pulse rate in PWM-inverter-fed induction
Publication -
MEDIUM-TERM WAVE AND CURRENT MODELLING FOR A MESOTIDAL WADDEN SEA COAST
Publication -
Quality assessments of electrochromic devices: the possibleuse of 1/f current noise
PublicationElementy wykorzystujące zjawisko elektrochromizmu, potrafiące zmieniać przezroczystość za pomocą ładowania/rozładowania ładunkiem elektrycznym, wykonano na bazie laminatów pokrytych porowatą strukturą tlenków Ni oraz tlenków Wi-V. Oba laminaty, na które naniesiono przewodzącą warstwę In2O3, przedzielono warstwą elektrolitu. Obserwowano szumy typu 1/f w prądzie I płynącym w trakcie rozładowywania urządzenia. Gęstość widmowa mocy...
-
Physical activity of future health care professionals: adherence to current recommendations
Publication -
Minimization of Eddy Current Losses in a Straight Rectangular Cross Section Conductor
Publication -
<title>Current developments of multicrucible technology of tailored optical fibers</title>
Publication -
Current methods and technologies for degradation of atrazine in contaminated soil and water: A review
Publication -
Investigations of non-uniform structure of the tetacene layer by photoen-hanced current
PublicationBadano stany pułapkujące nośniki w powierzchniowych obszarach warstwy tetra-cenu. W badaniach wykorzystano metodę prądów fotowzmocnionych. Wykazano obe-cność różnych rozkładów energetycznych pułapek przy obu powierzchniach war-stw tetracenu.
-
Theoretical analysis of current induced by high-energetic radiation in dielectric materials
PublicationW pracy poddano analizie mechanizmy generacji i rekombinacji nośników ładunku w obecności wysokoenergetycznego promieniowania. Przedstawiono zależności gęstości prądu elektrycznego od natężenia promieniowania i napięcia polaryzujacego próbkę.
-
Dynamic current-voltage characteristics of dielectrics with extremely low heat conductivity
PublicationZaprezentowano teoretyczny opis metody dynamicznych charakterystyk prądowo-napięciowych w przypadku znacznego gradientu temperatury w ciałach stałych o przewodności jonowej. Otrzymano rozwiązania równania transportu oraz równania charakterystyk, odnoszące się do ruchu cienkiej warstwy nośników ostałej grubości oraz warstwy rozszerzającej się. Podano także przybliżone wyrażenia opisujące czas przelotu nośników. Wyniki zweryfikowano...
-
Effect of contactless hybrid current limiter on voltage dips in power system
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
Magnetic field effects on emission and current in Alq3 - based electroluminescent devices.
PublicationW pracy zaobserwowano stromy wzrost natężenia elektroluminescencji w polach magnetycznych nie przekraczających 300mT. Efekt ten wywołany jest magnetyczno polową redukcją stopnia zmieszania singletowych i trypletowych par elektron dziura, wymuszonego przez nadsubtelne oddziaływanie spinów elektronowych z ich otoczeniem jądrowym.
-
Effect of contactless hybrid current limiter on voltage dips in power system.
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
Photoenhanced current as a tool for investigating non-uniform structures of tetracene layer.
PublicationPowierzchniowe prądy fotowzmocnione używane były jako narzędzie do badań fizycznych własności powierzchni warstw od strony podłoża, a także od strony przeciwległej podłożu.
-
Detection of stray current field interference on metal constructions using STFT
PublicationZaprezentowano metodę detekcji pola prądów błądzących wykorzystującą krótkoczasową transformatę Fouriera STFT. Ten sposób analizy umożliwia wyznaczenie zmian spektralnej gęstości mocy sygnału (np. potencjału konstrukcji) w funkcji czasu. Przedstawiono rezultaty analizy zmian potencjału w polu prądów błądzących generowanych przez trakcję tramwajową. Spektrogramy są kompozycją prążków w łącznej dziedzinie czasu i częstotliwości....