EXPERIMENTS AND SIMULATIONS FOR LAPAROSCOPICVENTRAL HERNIA REPAIR IMPROVEMENT
PublicationThe authors conducted a wide experimental and numerical study in order to determine effective approaches in the laparoscopic VH repair. At first the study covered identification of mechanical properties of the abdominal fascia, implants, tacks and transabdominalsutures. Basis on these data, the one and two-dimensional mathematical models were formulated and a number of numerical static and dynamic analyses were carried out. Then...
-
Mechanical properties of mosquito nets in the context of hernia repair
PublicationThe paper deals with issue of applying mosquito nets as implants in hernia repair, which have already been used in resource-poor developing countries. Uniaxial tensile tests have been conducted on polyester mosquito meshes in two orthogonal directions. Non-linear elastic constitutive laws parameters have been identified to be applied in dense net material models. Mechanical performance of tested mosquito nets has been compared...
-
Two-criteria optimisation problem for ventral hernia repair
PublicationTwo-criteria optimisation problem related to laparoscopic ventral hernia repair is formulated in this paper. An optimal implant from a given set and its orientation is sought. The implant is subjected to kinematic extortions due to a patient’s body movement and intra-abdominal pressure. The first criterion of the optimisation problem deals with the reaction force in the implant fastener, while the deflection of the implant constitutes...
-
Assessment of usefulness of different tacks in laparoscopic ventral hernia repair
PublicationLaparoscopic ventral hernia repair is becoming a popular technique with good results and fast postoperative recovery. The mesh is placed directly under the peritoneum and anchored with transabdominal sutures and tacks. However, the ideal size of the mesh covering the hernia orifice is know, nor the ideal type or amount of tacks has to be described.
-
Paraesophageal Hernia Repair Followed by Cardiac Tamponade Caused by ProTacks
Publication -
Mathematical modelling of implant in an operated hernia for estimation of the repair persistence
PublicationThis paper presents mathematical modelling of an implanted surgical mesh used in the repair process of the abdominal hernia. The synthetic implant is simulated by a membrane structure. The author provides a material modelling of the implant based on the dense net model appropriate for technical fabrics. The accuracy of the proposed solution is evaluated by comparing the simulations of the dynamic behaviour of the system with the...
-
Mechanical compatibility of implants used in hernia repair with abdominal wall
PublicationThe paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...
-
SIMULATION OF PROCEED® SURGICAL MESH APPLIED TO VENTRAL HERNIA REPAIR
PublicationIn the present research, Proceed® implant is considered. The system is subjected to short-time dynamic pressure load, similar to post-operative cough naturally occurring in human abdomen. The model refers to a clinical case of 5cm of hernia operated by Proceed implant fixed by 15 joints every 3cm around the orifice. The simulations of the implanted mesh are performed by means of the Finite Element Method. The implant is modelled...
-
Mechanical Modelling of Human Fascia in the Problem of Ventral Hernia Repair
PublicationPraca dotyczy badań doświadczalnych tkanki ludzkiej oraz symulacji numerycznej zachowania tej tkanki. Na podstawie eksperymentu dokonuje się identyfikacji modelu materiałowego tkanki a następnie w celu wweryfikacji przeprowadza się symulacje numeryczną zachowania modelowanej struktury. Celem badań jest uzyskanie informacji przydatnych podczas leczenia przepuklin brzusznych u ludzi.
-
Mechanical behaviour of knit synthetic mesh used in hernia surgery
PublicationPurpose: There is a discussion in literature concerning mechanical properties and modelling of surgical meshes. An important feature of elastic modulus dependency on load history is taken into account in this paper, as implants are subjected to variable loading during human activity. The example of DynaMesh®-IPOM surgical implant is studied. Methods: The analysis is based on failure tension tests and cyclic loading and unloading...
-
In vivo performance of intraperitoneal onlay mesh after ventral hernia repair
PublicationBackground: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures...
-
IMPLANT USED IN HERNIA REPAIR UNDER PHYSIOLOGICAL MOVEMENTS OF HUMAN ABDOMEN
PublicationThe study deals with the mechanical behaviour of implant used in repair of abdominal hernia. The influence of orientation of the orthotropic implants in different areas of abdominal wall is studied.
-
Dynamics of mechanical model of implant-tissue system in ventral hernia repair
PublicationThe paper deals with a finite element modelling of implants in the problem of ventral hernia repair. The synthetic mesh implanted in the abdomen during surgery is here modelled as a membrane structure. Thesystem undergoes the internal abdominal pressure that occurs during the postoperative cough, the load identified in the literature as the main cause of the connection failure and hernia recurrence. The model can be used to estimate...
-
Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair
PublicationEven though the incisional hernia repair surgery is a well known procedure, mechanical properties of the tissue-implant system are unknown so the implantation of the repairing mesh is quite intuitive and, recurrences of the illness still take place. The main objective of the study is to define an operated hernia model that can be used for surgery planning and the assessment of the repair persistence. The load applied to the structure...
-
Constitutive Modelling of Knitted Abdominal Implants in Numerical Simulations of Repaired Hernia Mechanics
PublicationThe paper presents a numerical approach to describe mechanical behavior of anisotropic textile material, which is a selected abdominal prosthesis. Two constitutive nonlinear concepts are compared. In the first one the material is considered composed from two families of threads (dense net model) and in the second one the material is homogeneous but anisotropic (as proposed by Gassel, Ogden, Holzapfel). Parameters of both models...
-
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublicationIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...
-
Cough influence on fascia-mesh system built for a hernia repair - an experimental research
PublicationAn experimental approach to identify stronger and weaker fixation schemes in laparoscopic ventral hernia repair is presented in the paper. Two types of implants, whose mechanical properties are significantly different and five kinds of connectors are considered. Physical models of operated hernia have been built using those materials and porcine abdominal tissue. The models have been subjected to dynamic impulse load, similar to...
-
A PRELIMINARY STUDY ON THE OPTIMAL CHOICE OF AN IMPLANT AND ITS ORIENTATION IN VENTRAL HERNIA REPAIR
PublicationThis paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic...
-
Antibiotic prophylaxis in open inguinal hernia repair: a literature review and summary of current knowledge
Publication -
Biomechanics of the front abdominal wall as a potential factorleading to recurrence with laparoscopic ventral hernia repair
PublicationThis study investigated the front abdominal wallto describe its elasticity in vivo and searched for elongationsthat possibly stretched an implanted mesh, therebycausing fixation failure and subsequent recurrence.To measure front abdominal wall elongations, amodel of fascia movements was created. Eight healthyvolunteers were measured during exercise to determine theextent of elongations in their front abdominal wall. Videoswere...
-
Surgical implant used in ventral hernia repair subjected to physiological pressure - computer simulation
PublicationW streszczeniu przedstawiono matemayczny model implantu wszczepionego pacjentowi podczas laparoskopowej naprawy przepukliny brzusznej. Wykonano go z użyciem metody elementów skończonych. Przyjęto ortotropowy model materiałowy implantu.
-
Towards Understanding of Mechanics of Hernia Managed by Synthetic Mesh in Laparoscopic Operation: A Single Case Study
PublicationIn this paper a research towards understanding of mechanics of ventral hernia operated with the use of Physiomesh Open image in new window implant and SecureStrap Open image in new window staples is described. Experimental and numerical studies are conducted for that purpose. Experimental works cover uni-axial tension tests of the implant samples and of the implant-staples-tissue system. Also experiments on implant-staples-tissue...
-
Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation
Publicationrelation to the different range of typical deformations observed in different directions and zones of abdomen surface due to the patients’ life activities, has a significant influence on the extreme junction forces in the mesh–tissue connections and hence the repair persistence. The finite element model of the orthotropic implant was developed, and the junction forces in the connections of tissue and mesh were studied. The kinematical...
-
Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia
PublicationThis paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative...
-
A FEM membrane model of human fascia-synthetic implant system in a case of a stiff ventral hernia orifice
PublicationPraca prezdstawia model matematyczny układu tkanka ludzka - implant syntetyczny w postaci tzw. siatki w leczeniu przepuklin brzusznych. Implant jest tu moelowany jako struktura membranowa. Ocena wpływu danych materiałowych oraz wstępnego napięcia na zachowanie pracującej membrany po implantacji została przedstawiona na podstawie analizy wrażliwości. Pracę podsumowują pewne wskazówki dla chirurgów implantujących siatki.
-
Modeling of the fascia-mesh system and sensitivity analysis of a junction force after a laparoscopic ventral hernia repair
PublicationW pracy rozpatrywano prosty model cięgnowy układu powięż-siatka do oszacowania siły połączenia siatki z powięzią po operacji laparoskopowej przepukliny brzusznej. Cięgno obciążone jest ciśnieniem wewnątrz brzusznym, symulującym kaszel, oraz przemieszczeniami jego końców wywołanymi skłonami pacjenta. Wpływ poszczególnych parametrów cięgna na siłę połączenia określono za pomocą analizy wrażliwości. Sformułowano pewne wnioski ważne...
-
Investigation of abdomen surface deformation due to life excitation: implications for implant selection and orientation in laparoscopic ventral hernia repair
PublicationVentral hernia is a common medical problem. Statistically there are around 10% recurrences of the sickness. The authors' former investigation proved edges of the hernia orifice displacements to be one of the factors causing recurrence. Thus, experimental investigation of the abdomen surface deformation due to some normal activities of people is studied.The extreme strains, their localization and directions are identified. The acquired...
-
Gdańska Międzynarodowa Szkoła Letnia na WETI
PublicationW dniach 5-12 września 2017 roku Katedra Algorytmów i Modelowania Systemów23, przy wydatnej pomocy,WETI, zorganizowała Międzynarodową Szkołę Letnią poświęconą algorytmom dla problemów optymalizacji dyskretnej.
-
Gdańska Międzynarodowa Szkoła Letnia na WETI
PublicationW dniach 6-12 lipca 2019 roku Katedra Algorytmów i Modelowania Systemów zorganizowała 3. Międzynarodową Szkołę Letnią poświęconą algorytmom dla problemów optymalizacji dyskretnej.
-
Walery Starczewski. Śladami założyciela Korporacji Akademickiej Helania
PublicationPrzedstawiono życiorys i dokonania inżyniera Walerego Starczewskiego, absolwenta Politechniki Gdańskiej z roku 1926 i założyciela Korporacji Akademickiej "Helania" w Gdańsku oraz działacza Stowarzyszenia "Polonia Technica" w USA
-
Flavonoids from Ficaria verna Huds.
Publication -
Nanocrystalline undoped ceria oxygen sensor.
PublicationW pracy przedstawiono wyniki badań struktury i elektrycznych właściwości nanokrystalicznego czujnika na bazie niedomieszkowanego tlenku ceru. Zbadano wpływ ciśnienia parcjalnego tlenu na rezystancję cienkowarstwowego tlenku ceru. Konduktancja tlenku ceru w zakresie stężeń tlenu od 10ppm do 100% ma charakter eksponecjalny z parametrem -0.25. Zbadano szybkość odpowiedzi oraz wpływ dwutlenku azotu oraz dwutlenku siarki na odpowiedź...
-
Safety and efficacy of a Ventralight ST echo ps implant for a laparoscopic ventral hernia repair – a prospective cohort study with a one-year follow-up
Publicationing new products Thus, every mesh prior to introduction in clinical settings should be tested with a dedicated tacker to discover the proper fixation algorithm. The aim of the study was to assess the safety and efficacy of the Ventralight ST implant with an ECHO positioning system and a dedicated fixation device, the SorbaFix stapler, in a prospective cohort of patients. Material and methods. The study was a prospective single...
-
Szkoła letnia Wydziału Architektury - artykuł w Piśmie PG
PublicationArtykuł opisuje tematykę cyklu szkół letnich Wydziału Architektury pn. "Architektura dla miejsca" Wakacyjne warsztaty stanowią realizację ważnego celu w dydaktyce projektowania architektonicznego, jakim jest gotowość projektanta do gromadzenia doświadczeń bezpośrednio w terenie i poznawania wielowymiarowych – ekologicznych, społecznych, kulturowych – uwarunkowań kształtowania przestrzeni. Małomiasteczkowe lub wiejskie, studio projektowania...
-
Lichenochora tertia (Phyllachorales): the third species of the genus growing on Xanthoria elegans
Publication -
Fouling mechanisms in anoxic-aerobic sequencing batch membrane bioreactor based on adapted Hermia models and main foulant characteristics
PublicationVarious derivatives of Hermia models (complete pore blocking, intermediate pore blocking, cake layer formation, and standard pore blocking) and different assessments of foulant characteristics have long been used to determine the membrane fouling mechanisms. Accordingly, this study aims to adapt Hermia models and their combination according to the operating conditions of an anoxic-aerobic sequencing batch membrane bioreactor (A/O-SBMBR)....
-
Electrical properties of nanocrystalline Sm-doped ceria ceramics
PublicationWłaściwości ceramiki z cerii zależa zwykle silnie od struktury ziaren. W pracy przedstawiono właściwości elektryczne ceramiki z cerii domieszkowanej samarem wykonanje w technologii 'net shape' posiadającej strukturę nanokrystaliczną.
-
Electrical properties of poros nanocrystalline undoped ceria oxygen sensor
PublicationW pracy zaprezentowano wykonanie czujnika z niedomieszkowanego tlenku ceru o nanometrowych ziarnach krystalicznych. Zastosowana metoda nanoszenia warstw zalicza się do metod niskotemperaturowych. Wytworzone warstwy przebadano za pomocą dyfrakcji rentgenowskiej, mikroskopii elektronowej oraz spektroskopii impedancyjnej. Wykonane czujniki charakteryzują się szybkim czasem odpowiedzi i stabilnym zachowaniem przy zmianach ciśnienia...
-
Quantitative Analysis of Flavonoids in the Flowers and Leaves of Ficaria verna Huds.
Publication -
Nanocrystalline doped zirconia and ceria films for fuel cell application
PublicationW artykule przestawiono porównanie właścowości warstw nanokrystalicznych przygotowanych w technologii 'net-shape'. Materiały te mają zastosowanie w tlenkowychogniwach paliwowych.
-
Nanocrystalline doped zirconia and ceria films for fuel cell application
PublicationW artykule przedstawiono i porównano właściwości nanokrystalicznych warstw ceramicznych przygotowanych na bazie tlenku ceru i tlenku cyrkonu.
-
Electrical properties of ceria films prepared by net shape technology
PublicationW pracy przedtswiono procedurę przygotowania gęstych warstw elektrolitu z wykorzystaniem technologii Net Shpe. Technologia ta na znaczne obniżenie temperatury przygotania tego typu warst. Okresloślono parametry elektryczne warst domieszkowanego ceru przygotowanych w tej technologii.
-
Flavonoids and Essential Oil of Bidens cernua of Polish Origin and in Vitro Antimicrobial Activity of the Oil
Publication -
Gigantic electro-chemo-mechanical properties of nanostructured praseodymium doped ceria
PublicationSome oxygen defective fluorites are non-Newnham electrostrictors, i.e., the electromechanical response does not depend on their dielectric properties. Here, we show gigantic electrostriction in nanocrystalline 25 mol% praseodymium doped ceria (PCO) bulk ceramics. The material was fabricated with a fieldassisted spark plasma sintering (SPS) process from high-purity nanoscale PCO powders (<20 nm). The SPS process consolidates the...
-
Ceria Based Protective Coatings for Steel Interconnects Prepared by Spray Pyrolysis
PublicationStainless steels can be used in solid oxide fuel/electrolysis stacks as interconnects. For successful long term operation they require protective coatings, that lower the corrosion rate and block chemical reactions between the interconnect and adjacent layers of the oxygen or the hydrogen electrode. One of the promising coating materials for the hydrogen side is ceria. Using standard sintering techniques, ceria sinters at around...
-
Benchmarking parków technologicznych w Polsce. Wyniki badania. - [Seria Innowacje]
PublicationAutorzy na podstawie przeprowadzonych badań dokonują benchmarkingu parków technologicznych w Polsce, wskazując na najlepsze rozwiązania w funkcjonowaniu analizowanych organizacji.
-
Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.
Publicationrepairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of highquality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. Method The authors conducted...
-
Spray pyrolysis of doped-ceria barrier layers for solid oxide fuel cells
PublicationGadolinium doped ceria (Ce0.8Gd0.2O2 − x-CGO) layer fabricated by spray pyrolysis is investigated as the diffusion barrier for solid oxide fuel cell. It is deposited between the La0.6Sr0.4FeO3 − δ cathode and the yttria stabilized zirconia electrolyte to mitigate harmful interdiffusion of elements. The parameters of the fabrication process are linked to the measured area specific resistances of the symmetrical cells and the efficiency...
-
Corrosion Study of Ceria Protective Layer Deposited by Spray Pyrolysis on Steel Interconnects
PublicationSingle fuel cells and electrolysis cells are assembled into stacks using interconnects in order to increase power and gas production capacity. The most common choice for the interconnect material is stainless steel. It has good electrical and mechanical properties and is also cost effective. One of the problems when using steel is the formation of a thermally grown oxide scale during use which has a lower electrical conductivity...
-
Nanocomposite nickel ceria cermet with low nickel content for anode-supported SOFCs
PublicationW pracy przedstawiono badania nanokompozytowego cermetu z zawartościa niklu 7.5, 11, 14% niklu w cermecie. Cermet przygotowno z wykorzystanim technologii net shape.