Filters
total: 1025
-
Catalog
- Publications 607 available results
- Journals 14 available results
- Publishing Houses 2 available results
- People 40 available results
- Inventions 1 available results
- Projects 16 available results
- Laboratories 2 available results
- Research Teams 8 available results
- e-Learning Courses 312 available results
- Events 23 available results
displaying 1000 best results Help
Search results for: ENERGETYKA TRAKCYJNA
-
Reactive Energy Billing in Operator Tariffs in Poland
PublicationThe paper describes the current method of reactive energy billing in the tariffs of distribution grid operators in Poland. The current solutions are subject to critical assessment. Issues related to the motivation effect of the current solutions on consumers are analysed. Problems that occur in relation with connecting distributed generators to the distribution grid and challenges related to prosumer billing are indicated.
-
Testing Situation Awareness Network for the Electrical Power Infrastructure
PublicationThe contemporary electrical power infrastructure is exposed to new types of threats. The cause of such threats is related to the large number of new vulnerabilities and architectural weaknesses introduced by the extensive use of Information and Communication Technologies (ICT) in such complex critical systems. The power grid interconnection with the Internet exposes the grid to new types of attacks, such as Advanced Persistent...
-
Skuteczne prognozowanie krótkoterminowe mocy farm wiatrowych
PublicationPrognozowanie mocy wytwórczej konkretnej farmy wiatrowej (FW) w horyzoncie 24-godzinnymwymaga zarówno wiarygodnej prognozy wietrzności, jak i narzędzi wspomagających. Narzędzie to jest dedykowanym modelem mocy farmy. Model powinien uwzględniać nie tylko ogólne zasady przetwarzania energii wiatru na energię mechaniczną, ale także cechy szczególnekonkretnej farmy. Liczba czynników wpływających na moc farmy jest duża i dokładna prognozamocy,...
-
Calculations of Short-Circuit Current Flows in Earth Wires of HV Lines
PublicationThis paper presents a method which enables calculating flows of short-circuit currents in earth wires of high voltage transmission lines, and its implementation in the form of a computer programme. The algorithm enables performing calculations for a double-fed line and starconnected lines (three terminal lines). The developed programme enables verifying dimensioning of earth wires in the context of their short-circuit thermal withstand...
-
The Possibility to use a Nuclear Power Plant as a Source of Electrical Energy and Heat
PublicationIn this article issues concernig the possibility of nuclear power plant (NPP) operation also as a source of heat, which means combined heat and power production, have been described. CHP work is possible and profitable only in those areas where high thermal power demand occurs, which means near city agglomerations such as Warsaw or the Tri-City. Two levels of thermal power delivered to the heating system have been considered. Preliminary...
-
Estimation of Selected Synchronous Generator Parameters Based on the Gradient Method
PublicationThe authors present a method for the estimation of synchronous generator model parameters using a gradient algorithm. The paper shows an example of model parameter estimation for a turbogenerator and hydrogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test.
-
Optimization of Nuclear Power Share in the Structure of Electricity Production in Poland in Time Perspective by 2060
PublicationThe author of this paper presented the results of a system analysis using MARKAL model, aiming at the optimization of nuclear power share in power generation structure in Poland in time perspective by 2060. Optimization criterion is the minimization of the objective function, i.e. the total cost of energy system, taking into account constraints related to CO2, SOx and NOx emissions and obligatory shares of electricity from renewable...
-
Technical and Economic Analysis of an Intermediate Size Photovoltaic Power Plant. Case Study
PublicationThe article presents an analysis of the construction of a photovoltaic power plant with an installed capacity of about 30 kW. The principles of selecting the basic elements of the plant are shown. The impact of a high constant price on the profitability of the project is highlighted. The article also describes the existing mechanisms for subsidizing the investment.
-
Thermal and Electrodynamic Risk of Residual Current Devices in the Case of Back-Up Protection by Overcurrent Circuit Breakers
PublicationResidual current operated circuit breakers without integral overcurrent protection should be back-up protected. As back-up protection devices, overcurrent circuit breakers are used. The maximum let-through energy and let-through current of the overcurrent devices were evaluated under laboratory conditions. The thermal and electrodynamic risk of residual current devices was analyzed.
-
Renewable Energy Sources on the Polish Electrical Energy Market
PublicationProduction of electricity from renewable energu sources in Poland is presented in the paper.The machanism of energy origin certifikates market and the proposal of mechanism modification are discused.
-
Power Electronics Building Blocks for implementing Smart MV/LV Distribution Transformers for Smart Grid
PublicationWith an observed increase in the involvement of active consumers in activities aimed at improving energy efficiency and increasing interest in producing energy from renewable sources, there is a need for the development of new technologies enabling the distribution network operators to offer new services and functionalities. Smart MV/LV distribution transformers are characterized by a compact three-stage design, including an...
-
Selected Technical Requirements for Photovoltaic Plant Interconnection with a Medium Voltage Grid
PublicationThe article discusses some selected technical requirements, which according to these authors should be recognised and met by photovoltaic power plants connected to national distribution grids in the context of their likely development. This development today is limited, since Polish legislation has not implemented the relevant EU Directive [8]. The study points out the purposefulness of incorporating the necessary requirements...
-
Modelling of power electronic compensators for the analysis of power system operation
PublicationThe article presents selected methods of modelling power electronic compensators in order to analyze their operation in the power systems. Advantages and disadvantages of models have been shown with an indication of their usefulness for modelling specific phenomena.
-
Human Factors in Nuclear Power Engineering in Polish Conditions
PublicationThe paper “Human factors in nuclear power engineering in polish conditions” focuses on analysis of dynamics of preparing polish society to build fi rst nuclear power plant in XXI century in Poland. Authors compare experience from constructing nuclear power plant Sizewell B (Great Britain) and Sizewell C, which is in preparation phase with polish nuclear power program. Paper includes aspects e.g. of creating nuclear safety culture and...
-
Energy Consumption Analysis Methods in Industry
PublicationThis paper overviews applied methods to evaluate energy consumption in Industry. The most important law regulations are presented, which decide on the necessity to conduct an effec - tive energetic economy. Basic assumptions are defined to calculate direct and cumulative energy consumption. The pros and cons of using each method are presented.
-
Badanie sieci świadomości sytuacyjnej dla infrastruktury elektroenergetycznej
PublicationWspółczesne systemy elektroenergetyczne są narażone na nowe rodzaje zagrożeń. Są one spowodowane lukami w zabezpieczeniach oraz słabościami architektonicznymi związanymi z szerszym zastosowaniem technologii teleinformatycznych (ICT) w tych systemach. Połączenie sieci elektroenergetycznych z Internetem naraża je na nowego rodzaju niebezpieczeństwa, takie jak ataki APT (ang. Advanced Persistent Threats) lub rozproszona odmowa usługi...
-
Hardware-Software Implementation of Basic Principles Simulator of Nuclear Reactor Processes
PublicationThe paper presents implementation process of basic principle simulators of a nuclear reactor processes. Simulators are based on point-models of processes: kinetics of neutrons, heat generation and exchange, poisoning and burning-up nuclear fuel. Reference simulator was developed in MATLAB/Simulink without taking into account real-time operation. Second simulator was built using the toolbox xPC with hard real-time requirements....
-
Laboratoryjny model odbioru oparty na przekształtniku częstotliwości o mocy 150 kVA i platformie Simulink Real-Time – koncepcja, realizacja, badania eksperymentalne
PublicationW artykule opisano koncepcję oraz sposób realizacji laboratoryjnego modelu odbioru o mocy 150 kVA. Odbiornik zaprojektowano w taki sposób, aby umożliwić emulację zmienności mocy dowolnego odbioru. Integralnym elementem modelu jest transformator z energoelektronicznym przełącznikiem zaczepów. W pierwszej części artykułu przedstawiono założenia, strukturę przyjętego algorytmu sterowania, wymieniono i opisano podstawowe wielkości...
-
Resonant Conditions in a Node with an SVC Compensator
PublicationThe primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.
-
The Concept of a Methodology for Selecting the Optimal Parameters of Heat Received from a Nuclear Power Plant Operating in a Partial Cogeneration Mode
PublicationThe paper presents the concept of the objective function which is to allow the selection of optimal parameters of the district heating system using a nuclear power plant operating in partial cogeneration mode. The concept is based on research carried out a number of years ago. The size of annual expenses was proposed as the objective function, which allows to compare the operation of a nuclear power plant in partial cogeneration...
-
Electricity Supplier Switching Process in Poland – a Process Based on the General Distribution Agreement
PublicationPoland, as a Member State of the European Union, is committed to respect the common rules on the electricity market, among other things. One of the most important examples of these regulations is the perception of energy as a commodity subject to competitive market mechanisms. Competitive processes introduced in the national electricity market enable energy consumers, i.a., choice of electricity supplier under the TPA formula....
-
Application of MARKAL model to optimisation of electricity generation structure in Poland in the long-term time horizon. Part II. Model and forecasts assumptions
PublicationIn this paper, the next in a series of publications on the subject, assumptions are presented of a power system development model in terms of electricity generation technology infrastructure in Poland, in the long term perspective until 2060. The model is based on the mathematical structure of the MARKAL optimization package. Among other things developed are a forecast of the final demand for electricity and heat, the current...
-
Identification and non-integer order modelling of synchronous machines operating as generator
PublicationThis paper presents an original mathematical model of a synchronous generator using derivatives of fractional order. In contrast to classical models composed of a large number of R-L ladders, it comprises half-order impedances, which enable the accurate description of the electromagnetic induction phenomena in a wide frequency range, while minimizing the order and number of model parameters. The proposed model takes into account...
-
Application of MARKAL model to optimisation of electricity generation structure in Poland in the long-term time horizon Part I - concept of the model
PublicationIn this paper, which inaugurates a series of papers on this subject, a concept is proposed of a power system development model with regard to the technological structure of electricity generation in Poland, in the long-term time perspective – until 2060. The model is based on the mathematical structure of the MARKAL optimization package. The paper presents a brief description of the tool used in the model research. In addition,...
-
Influence of operation of national experimental nuclear reactor on the natural environment
PublicationThis paper presents the impact of experimental nuclear reactor operations on the national environment, based on assessment reports of the radiological protection of active nuclear technology sources. Using the analysis of measurements carried out in the last 15 years, the trends are presented in selected elements of the environment on the Świerk Nuclear Centre site and its surroundings. In addition, the impact of research results...
-
Wpływ pracy doświadczalnego reaktora jądrowego na krajowe środowisko naturalne
PublicationW artykule, na podstawie raportów oceny stanu ochrony radiologicznej eksploatowanych źródeł technologii jądrowych, przedstawiono wpływ pracy doświadczalnego reaktora jądrowego na krajowe środowisko naturalne. Korzystając z analiz wyników pomiarów przeprowadzonych w ostatnich 15 latach, przedstawiono trendy zmian w wybranych elementach środowiska naturalnego na terenie i w otoczeniu ośrodka Świerk. Ponadto zaprezentowano wpływ...
-
The Large Customer Reactive Power Control Possibilities
Publicationn this paper the authors wish to draw attention to the rationale for, and the possibility of, the use of local reactive power sources by the Transmission Node Master Controller (TNMC). Large Customers (LC) are one of the possible reactive power sources. The paper presents the issues related to the need for coordination between the control systems installed in the LC network, and coordination between control systems of the LC as...
-
Market Price Prediction of Property Rights from Gas Fired Plants or Plants with Total Installed CHP Source Capacity Below 1 MW until 2025
PublicationThe resolution on the Polish Energy Policy until 2030 (PEP-30) was adopted by the Council of Ministers on 10 November 2009. The document specifies the combined electricity and heat generation as a direction of pursuing the goals of energy efficiency, fuel and energy supply security, competitive fuel and energy markets development, and reduction of the energy sector’s environmental impact. PEP-30 assumes that electricity generation...
-
Comparison of Transmission Capacities of Two Regulation Systems: Lateral and in-phase Control Transformers
PublicationThis paper presents a comparison of regulation capabilities of lateral and in-phase control transformers in a selected node of a power system. Their regulation capabilities are presented, as well as cross-system exchange options.
-
Comparison of AHP and Numerical Taxonomy Methods Based on Biogas Plant Location Analysis
PublicationThe paper presents a comparison of the multi-criteria Analytic Hierarchy Process (AHP) method and numerical taxonomy in biogas plant location selection. Biogas plants are sources that will significantly contribute to the implementation of the provisions of the energy and climate package for Poland by 2030. Increasing the share of energy produced from renewable sources, e.g. biogas plants, will increase the country’s energy security....
-
Possibilities of Increasing the Overall Efficiency of Gas-steam CHP Microplant
PublicationThe paper presents ways to increase the efficiency of a gas-steam micro power plant by modifying the cycle combination. The modification consists in partial release of the fluid downstream of the gas turbine and using it for ORC fluid overheating and evaporation. Advantages of this solution over the simplest gas and steam cycles’ combination are demonstrated.
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublicationThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Porównanie możliwości przesyłowych dwóch układów regulacyjnych: transformatorów z regulacją poprzeczną oraz transformatorów z regulacją wzdłużną
PublicationW artykule przedstawiono porównanie możliwości regulacyjnych transformatorów z regulacją poprzeczną oraz wzdłużną w wybranym węźle systemu elektroenergetycznego. Zaprezentowano możliwości regulacyjne tych układów oraz możliwości kształtowania wymiany międzysystemowej.
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublicationThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
Hydropower potential of the lower Vistula
PublicationThis paper presents an estimate analysis of the hydropower potential of the lower Vistula River from Warsaw to Gdańsk Bay. The calculations were made for a hydraulic model of the lower Vistula which takes into account potential development of barrages in a cascade system. Results obtained from the model simulations and from hydrological calculations were used to estimate the power of hydropower plants and the average annual energy...
-
REALIZACJE SPRZĘTOWO-PROGRAMOWE SYMULATORÓW PODSTAWOWYCH ZASAD PRZEBIEGU PROCESÓW REAKTORA JĄDROWEGO
PublicationW artykule przedstawiono możliwości i proces budowy symulatorów podstawowych zasad działania procesów reaktora jądrowego. Proces budowy i badania oparte są na modelach punktowych: kinetyki neutronów, procesów generacji i wymiany ciepła oraz procesów zatruwania i wypalania paliwa. Badano możliwości realizacji symulatorów, wykorzystując różne środowiska programowe i platformy sprzętowe. Referencyjny symulator został opracowany w...
-
Mechanical Strength of MV Ship-switchgear During Fault Arc
PublicationIn the paper the analysis of pressure stressed in enclosure during fault arc inside switchgear is pre-sented as well. There is introduced the method based on determining stresses which are sum of tensile stresses (membrane) and deflection stresses. For tensile stresses nalysis the energy method, for unrestrainedly supported rectangular plate, was used. In the further part of the paper, the calculations and measurements results...
-
Kogeneracja jądrowa: analiza technicznych możliwości i szacowanie kosztów
PublicationW artykule przedstawiono koncepcję równoległego połączenia elektrowni jądrowej, przystosowanej do oddawania ciepła do celów grzejnych, z istniejącymi elektrociepłowniami i ciepłowniami w rejonie zasilania, w tym przypadku z ciepłowniczymi systemami Wejherowa i Gdyni. Zaproponowano warianty uciepłownienia elektrowni jądrowej, w postaci zasilania wymienników ciepłowniczych parą pobieraną z upustów części niskoprężnej turbiny...
-
Zastosowanie metody AHP do porównania kryteriów wyboru lokalizacji budowy farmy wiatrowej
PublicationArtykuł przedstawia opis oraz porównanie kryteriów wyboru lokalizacji farmy wiatrowej. Kryteria te uwzględniają pomiary wietrzności na rozpatrywanym terenie, lokalizację turbin wiatrowych, lokalizację linii elektroenergetycznej służącej do przesyłu wyprodukowanej energii elektrycznej od farmy wiatrowej do stacji elektroenergetycznej (GPZ), infrastrukturę towarzyszącą, warunki techniczne przyłączenia do sieci elektroenergetycznej...
-
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments
PublicationFirst section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...
-
Advanced Control Structures of Turbo Generator System of Nuclear Power Plant
PublicationIn the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multi-regional fuzzy control systems with local linear controllers, including...
-
A Preliminary Study and Analysis of Tidal Stream Generators
PublicationFor a sustainable future, tidal energy can play a vital role. Tidal energy relies on the gravitational pull of the Moon and the Sun along with the centrifugal forces created by the Earth. Tidal barrage uses the potential energy from the tide and has been very successful in electricity production. With the help of a turbine, kinetic energy can also be harnessed from tidal currents to generate electricity. However, it is not economically...
-
Ranking of Generation Source Locations by a Hybrid Multi-Criteria Method
PublicationThe paper presents a ranking of the locations of eight renewable energy sources (RES) made using a hybrid multi-criteria analysis method. The method is a combination of the analytical hierarchical process (AHP) method and numerical taxonomy. The considered generating sources, i.e. solar plants, biogas plants, and wind farms are sources that will significantly contribute to implementing the provisions of the energy and climate package...
-
An Optimal Power Point Tracking Algorithm in a Solar PV Generation System
PublicationThe non-linearity in I-V characteristics of a PV panel requires to be operated at knee point to extract maximum power. In order to operate the panel at optimal point, maximum power point tracking (MPPT) algorithm is employed in the control structure. The main objective of MPP tracking is to keep the operation at knee point of I-V characteristics under varying condition of temperature and solar insolation. Under non uniform solar...
-
Calculation of the Effects of Implementing a DSM Electricity Demand Management Strategy Using the Example of Analysis of Changes in the Power System Load
PublicationThe paper presents the impact of implementing Demand Side Management (DSM) solutions through proper management and control of the process of charging and discharging electric car batteries. As a result, the daily load curves were shaped so as to fill valleys and cut down peaks. Therefore, the implementation of power demand management solutions had a significant impact on the power system operation. The impact of DSM solutions manifested...
-
Hydro Power Plant in the Process of Voltage Control in the Electric Power System and the System Restoration
PublicationThe article covers selected issues related to the share of hydroelectric power in the process of rebuilding the power system after black-out and voltage control during that process. Selected results of measurements made during the creation of the transmission chain for the need to start a block of a thermal power plant from a hydroelectric power plant were presented.
-
Installation of Compensators in the Power System Transmission Grid
PublicationThe article discusses issues of reactive power compensation in transmission grids, with particular focus on the selection of compensator locations and basic parameters. Attention was focused on modern power electronics systems that ensure full automatic compensator adjustment to voltage or power criteria.
-
Cross-Bonding of MV Cable Lines for Energy Losses Decrease
PublicationCurrently, almost all medium voltage cable lines (MV) operate with the return wires earthed at both ends of the cable. Such a way of operation causes that during normal states of operation as well as during disturbances, e.g. short-circuits, in the return wires induce currents whose values mainly depend on the currents flowing in the phase wires. These currents in normal operating states are a source of additional energy losses...
-
Qualitative Indicators Used to Select the Placement and Parameters of Energy Storage Installed in the Distribution Network
PublicationThe technology related to energy storage has developed in recent years. Continuous improvement of the solutions available on the market resulted in wider usability of energy storage. They are also increasingly used in a distribution network. This study contains a synthesised description of physical features of the energy storage used in distribution networks. Several criteria of algorithms used to determine the placement and...
-
Oversizing the photovoltaic generator capacity in a micro photovoltaic plant
PublicationA significant part of photovoltaic micro installations in Poland is characterized by photovoltaic generator oversizing in relation to the inverter. The idea of oversizing, however, still raises doubts among some plant owners. In the paper, the energy yield of installation with an oversized and not oversized photovoltaic generator is presented on selected examples, showing the legitimacy of oversizing.