Filters
total: 3770
-
Catalog
- Publications 3044 available results
- Journals 72 available results
- Conferences 10 available results
- People 118 available results
- Inventions 1 available results
- Projects 5 available results
- Research Equipment 1 available results
- e-Learning Courses 36 available results
- Events 3 available results
- Offers 1 available results
- Open Research Data 479 available results
displaying 1000 best results Help
Search results for: TITANIUM DIOXIDENANOTUBESANODIZATIONLASER ANNEALINGCONDUCTING POLYMERELECTROCHROMIC DEVICE
-
Adaptive acoustic crosstalk cancellation in mobile computer device
PublicationThe cancellation of acoustic crosstalk is employed to enhance the stereo image in mobile listening conditions. A practical setup employing a mobile computer is employed. The adaptation of the crosstalk cancellation filter to the position of the listener's head is featured. The measurement evaluating the possibility of practical application of the method are described. The head and torso simulator was used for measurements. The...
-
Fitting the mobile device characteristics to the user's hearing preferences
PublicationA method for fitting the mobile computer audio characteristics to the user's hearing preferences is proposed. The process consists of two stages: calibration and dynamics processing. During the calibration phase the user performs a loudness scaling test giving their response regarding the perceived loudness. The dynamics processing made on above basis sets the loudness to the most comfortable level. The processing accounts both...
-
Using wearable device for biomedical signal acquisition and processing
PublicationIn this paper we present the research conducted on synchronous measurements of biosignals. The experiment was conducted to evaluate the possibility of estimating vital signs based on eye tracking. Method: The eGlasses platform was used for acquisition of ECG, respiration rate, eye and pupil movement and blood pressure. Data were acquired in three 5 min. intervals during which a subject was performing certain tasks. The signals...
-
COMPOSITE MATERIAL SELECTION FOR A PATIENT TRANSFER ASSIST DEVICE
PublicationLaminates - layered composites containing at least two elements (matrix and reinforcement) widely used in industry have also found their usage in medicine. Their main feature is the ability to modify the material in order to obtain the required properties. Depending on the needs, we can modify reinforcement, type of resin or the method of bonding substrates. Commonly used fibers are: carbon fiber, glass and aramid fibers; resins...
-
A device for measuring heat flux on a rocket skin surface
PublicationA novel method for measuring heat flux on a surface is presented. It is an extensive upgrade of currently known heat flux sensors used mostly in civil engineering. As the thermal environment of launchers, especially sounding rocket can have an enormous negative effect on payload, careful considerations have to be taken in the process of preparing insulation. Usually, thermal data provided by the launch vehicle manufacturer is limited...
-
Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment
PublicationNowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze...
-
Application of titanium dioxide thin films in fiber optic sensors
PublicationThe advance in the nanotechnology and fabrication of micro- and nanostructures has significant impact on development of new optical sensors. Presented study focuses on the applications of the titanium dioxide (TiO2) thin films in fiber optic sensors. The concept of a sensing fiber optic interferometer integrating TiO2 thin film is presented. The cavity of this interferometer is delimited by a 80 nm film fabricated on the end-face...
-
Modification of titanium dioxide with platinum ions and clusters: application in photocatalysis
PublicationW celu polepszenia właściwości fotokatalitycznych, TiO2 (komercyjny-P25 oraz syntezowany metoda zol-żel) był domieszkowany za pomocą jonów lub klasterów [Pt3(CO)6]62- platyny. Własności fizyczne fotokatalizatorów były badane za pomocą elektronowego mikroskopu transmisyjnego (TEM), dyfraktometru rentgenowskiego (XRD) oraz analizatora powierzchni właściwej (BET). Dyfuzyjna spektrometria odbiciowa (DRS) została zastosowana w celu...
-
Photocatalytic activity and surface properties of carbon-doped titanium dioxide
PublicationTiO2 domieszkowany węglem otrzymano poprzez hydrolizę izopropanolanu tytanu(IV) i kalcynację w 350ºC w atmosferze powietrza przez 2h. Przeprowadzone badania wykazały, że fenol (0.21 mM) jest efektywnie degradowany w fazie wodnej, w obecności otrzymanego fotokatalizatora oraz światła z zakresu widzialnego (λ>400 nm). Pole powierzchni właściwej otrzymanego C-TiO2 wynosiło około 127 m2/g, fotokatalizator absorbuje światło z zakresu...
-
Anodized multi – component titanium alloys carrying antibacterial features
Publication -
Environmental degradation of titanium biomaterials: mechanisms, effects, testing and evaluation
PublicationPrzedyskutowano możliwe przyczyny oraz mechanizmy degradacji biomateriałów tytanowych, używanych jako długoterminowe implanty stawów. Dokonano przeglądu wpływu impalntów metalicznych w ludzkim ciele. Przedstawiono bieżące procedury badania oraz ich wady. Zaproponowano procedurę oszacowania biomateriałów na implanty.
-
Preparation of the porous biomaterial based on titanium alloy for orthopaedic implants
PublicationObecnie tytan i jego stopy (Ti-6Al-4V lub Ti-13Nb-13Zr) są szeroko stosowane jako biomateriały dla implantów ortopedycznych. Stale prowadzone są badania nad ich najlepszą odpornością na korozję i zużycie ścierne oraz biozgodnością i bioaktywnością. Obecne badania również skoncentrowane są na projektowaniu, wytwarzaniu i właściwościach materiałów porowatych na podstawie na przykład stopu tytanu (Ti-13Nb-13Zr), które mogą być stosowane...
-
Aggregation of Rhodamine 6G in titanium dioxide nanolayers and bulk xerogels
PublicationNanolayers and bulk xerogels of Rhodamine 6G (Rh6G) in titanium dioxide (Rh6G/TiO2) were prepared using the sol–gel method. The spectroscopic and structural properties of these two types of hybrid matrices were studied as a function of dye concentration. In both cases absorption, fluorescence and time resolved emission spectra show the formation of fluorescent aggregates. The observed stronger changes in characteristics of bulk...
-
Impedance Studies of Phosphate-iron Glasses Containing Niobium and Titanium
PublicationThe ac and dc conductivity in phosphate-iron-niobate glasses with addition of titanium oxide was investigated as a function of temperature and frequency with the use of impedance spectroscopy. The topography and microstructure of glasses were investigated by the means of X-ray diffraction (XRD), scanning electron microscopy (SEM), and confocal microscopy methods. The obtained results show that all samples are amorphous but they...
-
Influence of titanium layer on counter electrode on electrical parameters of DSSC
PublicationIn this paper the influence of the Ti layer thickness at counter-electrode on electrical parameters of DSSCs was examined. The transparent conductive oxide – less (TCO-less) counter electrodes (CE) with titanium layers and platinum as catalyst on Bk7 glass were prepared. Thin metallic films were deposited by means of magnetron sputtering (titanium) and Pulsed Laser Deposition (platinum). The counter electrode with Pt layer on Fluorine...
-
Optimalization of titanium acaffold design using fuzzy reasoning approach
PublicationOpracowano metodę wnioskowania rozmytego do oszacowania geometrii scaffoldu Ti6Al4V, otrzymanego przy użyciu metody metalurgii proszków. Zaproponowana metoda umożliwia oszacowanie i optymalizację architektury scaffoldu poprzez dobór odpowiednich parametrów procesu. Zaprojektowano i przeprowadzono symulację działania sterownika rozmytego (FLC) za pomocą oprogramowania Matlab.
-
Preparation and photocatalytic activity of iron-modified titanium dioxide photocatalysts
PublicationTiO2 modyfikowany żelazem otrzymano dwiema metodami: metodą zol-żel oraz metodą impregnacji powierzchniowej. Fotokatalizatory kalcynowano w temperaturze 400C. Jako matrycę TiO2 zastosowano komercyjnie dostępne proszki ditlenku tytanu: P25 (Evonik, Niemcy, 50m2/g) oraz ST-01 (Ishihara Sangyo, Japonia, 300m2/g). Charakterystyka otrzymanych fotokatalizatorów obejmowała wyznaczenie właściwości absorpcyjnych, powierzchni właściwej BET...
-
Physicochemical and photocatalytic characterization of mesoporous carbon/titanium dioxide spheres
Publication -
Preparation of nano-tubular oxide layers on titanium alloy Ti13Nb13Zr
PublicationThe article presents results of oxidation tests and corrosion investigations of titanium alloy Ti13Nb13Zr preformed at different conditions. The oxide layers have been formed using electrochemical method in 2M H3PO4 + 0,3% HF solution for 30 min. and 1h at 20V constant voltage. The corrosion tests heve been made with poteniodynamic method in Ringer's solution at pH ranged 3 and 7. It has been shown that the nano-oxide films, which...
-
Biological and mechanical research of titanium implants covered with bactericidal coating
PublicationThe paper concerns the biological and mechanical properties of titanium implants with an antibacterial coating. The Ti13Zr13Nb alloy samples were coated with hydroxyapatite (HAp) coatings using the electrophoretic deposition technique (EPD). Subsequently, the surface of the samples was modified with silver, copper, and nickel nanoparticles by the immersion method. Different titanium sample types (i.e. HAp-only and nanometals-enriched...
-
Electron interactions with Bis(pentamethylcyclopentadienyl) titanium(IV) dichloride and difluoride
PublicationWe present a combined experimental and theoretical study of the interaction of electrons with Bis(pentamethylcyclopentadienyl)titanium(IV) dichloride (Cp∗2TiCl2) and difluoride (Cp∗2TiF2). We report the experimental measurements of partial cross sections for the dissociative electron attachment (DEA) and the electron ionization (EI) mass spectra of isolated molecules. Estimates of the absolute cross sections are done on the basis...
-
Modification of titanium dioxide towards photocatalytic activity in visible light
Publication.
-
Noise of optoelectronic coupled devices
Publication -
Organic light emitting devices
PublicationW pracy przedstawiono podstawowe procesy fizyczne zachodzące w organicznych emiterach elektroluminescencyjnych oraz parametry techniczne tego typu układów.
-
Noise of optoelectronic coupled devices.
PublicationOpisano trzy systemy do pomiaru szumów transoptora a mianowicie: system do pomiaru szumów m. cz. diod LED, system do pomiaru szumów m. cz. fototranzystorów oraz system do pomiaru szumów m. cz. transoptorów. Przedstawiono wyniki pomiaru szumów m. cz. próby 13 transoptorów. Określono współczynnik korelacji między intensywnością szumów a wybranymi parametrami stałoprądowymi tych transoptorów.
-
Noise of optoelectronic coupled devices.
PublicationOpisano dwa systemy do pomiaru szumów transoptorów. System do pomiaru szumów fototranzystora oraz system do pomiaru szumów transoptora. Przedstawiono porównanie wyników pomiarów szumów 27 transoptorów trzech różnych producentów.
-
Service and service decomposition model - theoretical foundation of it service management
PublicationThe publication contains different definitions of Service - one of the fundamental IT Service Management term. It describes types of Service attributes nad introduces so-called ''distinguish functions'' in order to propose different categories of Services. It proposes both general model of Service decomposition and practical model based on CMDB implementation limitations. In summarizes obtained results and gives some remarks about...
-
Design of a continuous intra-oral distraction device for mandibular bone
PublicationIn this paper we present example of a specific device used for distraction osteogenesis. Distraction osteogenesis (also called callus distraction, collotasis or osteodistraction) is a surgical process for reconstructing bone deformities or lengthening bones.
-
Rehabilitation device supporting active and passive upper limb exercises
PublicationThis article presents a mechatronic solution for rehabilitation devices supporting active and passive exercises in persons with motor dysfunctions of the upper limbs in the area of the elbow and shoulder joints. A planar positioner integrated with original software and a control system, served as the basis for creating the present solution. Bellman’s programming method was applied to optimize the motion trajectory of the planar...
-
A Method and Device for 3D Recognition of Cutting Edge Micro Geometry
Publication -
A Method of Lathe Checks Measurement; SMOF device and its software
Publication -
Auto adaptation of mobile device characteristics to various acoustic conditions
PublicationThe proposed methodology of auto adaptation of the mobile device characteristics to various acoustic conditions is presented in the paper. The first goal of this study was to determine the parameters of the acoustic path of the mobile device, for both transmitting (speaker) and receiver (microphone). Results of the measurement of characteristics of mobile devices were presented. Information about characteristics of individual parts...
-
A Method and Device for 3D Recognition of Cutting Edge Micro Geometry
PublicationA very useful method was successfully applied in the investigation of tools for machining wood and wood based composites. It allows scanning of the cutting edge micro geometry in three dimensions and reproducing it in a virtual space as a 3D surface. The application of the method opens new possibilities of studying tool wear by scanning, including the calculation of volume loss and other analysis of tool wedge geometry along and...
-
Device-independent quantum key distribution based on measurement inputs
PublicationWe provide an analysis of a family of device-independent quantum key distribution (QKD) protocols that has the following features. (a) The bits used for the secret key do not come from the results of the measurements on an entangled state but from the choices of settings. (b) Instead of a single security parameter (a violation of some Bell inequality) a set of them is used to estimate the level of trust in the secrecy of the key....
-
A New Technique of Spine Disease Treatment Supported by ADRSK1 Device
Publication -
Shrinking-shifting and amplifying-shifting device using transformation optics
PublicationBased on transformation optics (TO), this paper uses geometric divisions and linear coordinate transformations to design “shrinking-shifting—and reshaping”, and “amplifying-shifting—and reshaping” devices. The proposed devices can reshape the sizes and locations of the wrapped-objects inside the core-region. The shrinking-shifting device shrinks the larger object into a smaller one and shifts it to different location, whereas the...
-
Design and material selection for a patient transport device in field hospitals
PublicationACKGROUND: A major cause of patient and hospital worker injuries occurs transferring patients between two planes. The main aim of this paper was to propose a design of patient’s lift and transfer apparatus for use in field hospitals. The assumption was to design lightweight, durable and ergonomic device using innovative material. The authors concentrated on partial elimination of manual lifting in order to device could work both...
-
Synthesis and hydrogen evolving catalysis of a panchromatic photochemical molecular device
PublicationA dinuclear hydrogen evolution photocatalyst [(tbbpy)2Os(tpphz)PtI2](PF6)2 (tbbpy = 4,4′-tert-butyl-2,2′-bipyridine; tpphz = tetrapyrido[3,2-a:2′,3′-c:2′′,3′′-h:2′′′,3′′′-j]phenazine) is synthesized in order to make use of the broader range of visible light absorption mitigated by the osmium center. In a first step, the activity of the complex for hydrogen evolution is investigated by evaluating the role of different electron donors...
-
Devices and Methods of Measurements
Journals -
IEEE CIRCUITS & DEVICES
Journals -
PLASMA DEVICES AND OPERATIONS
Journals -
Reactivity study of a β-diketiminate titanium(III) complex with a phosphanylphosphido ligand towards chlorophosphanes. A new method of synthesis of β-diketiminate titanium(IV) complexes with versatile phosphanylphosphinidenes
PublicationThe reactivity of ab-diketiminate titanium(III) complex with a phosphanylphosphido ligand, [MeNacNacTi(Cl){g2-P(SiMe3)-PtBu2}] (1)(MeNacNac= [Ar]NC(Me)CHC(Me)N[Ar]; Ar = 2,6-iPr2Ph), was investigatedtowards selected chlorophosphanes, such astBu2PCl,iPr2PCl, Cy2PCl, (Cy)tBuPCl, (Me)tBuPCl, (Ph)tBuPCl, Ph2PCl, (iPr2N)tBuPCl and (Et2N)2PCl. The reactions withtBu2PCl and Ph2PCl lead mainly to theearlier described complex [MeNacNacTi(Cl){g2-P-PtBu2}]...
-
Effect of double thermal and electrochemical oxidation on titanium alloys for medical applications
PublicationThe research focuses on the development and characterization of innovative thin hybrid oxide coatings obtained in subsequent processes of thermal (TO) and electrochemical (EO) oxidation. Four different surface modifications were investigated and the microstructure was determined, the mechanical, chemical and biological properties of the Ti-13Nb-13Zr alloy were assessed using scanning electron microscopy, X-ray dispersion analysis,...
-
Comprehensive Evaluation of the Biological Properties of Surface-Modified Titanium Alloy Implants
PublicationAn increasing interest in the fabrication of implants made of titanium and its alloys results from their capacity to be integrated into the bone system. This integration is facilitated by different modifications of the implant surface. Here, we assessed the bioactivity of amorphous titania nanoporous and nanotubular coatings (TNTs), produced by electrochemical oxidation of Ti6Al4V orthopedic implants’ surface. The chemical composition...
-
Effects of the Origin and Deacetylation Degree of Chitosan on Properties of Its Coatings on Titanium
PublicationThe properties of chitosan coatings on titanium surfaces may be influenced by a variety of factors, including their chemical characteristics and the deposition method. The aim of this research was to determine the influence of a chitosan’s origin (a type of shrimp) and deacetylation degree (DD), when deposited on a very smooth titanium surface, on adhesion and biological behavior. The tests were performed using chitosan of a degree...
-
In Vitro Biological Characterization of Silver-Doped Anodic Oxide Coating on Titanium
PublicationDespite the high biocompatibility and clinical effectiveness of Ti-based implants, surface functionalization (with complex osteointegrative/antibacterial strategies) is still required. To enhance the dental implant surface and to provide additional osteoinductive and antibacterial properties, plasma electrolytic oxidation of a pure Ti was performed using a nitrilotriacetic acid (NTA)-based Ag nanoparticles (AgNP)-loaded calcium–phosphate...
-
Nanotubular oxide layers and hydroxyapatite coatings on porous titanium alloy Ti13Nb13Zr
PublicationThe surface condition of an implant has a significant impact on response occurring at the implant-biosystem border. The knowledge of physical-chemical and biological processes allows for targeted modification of biomaterials to induce a specified response of a tissue. The present research was aimed at development of technology composing of obtaining the nanotube oxide layers on a porous titanium alloy Ti13Nb13Zr, followed by the...
-
Modification of Titanium (IV) Dioxide with Small Silver Nanoparticles: Application in Photocatalysis
PublicationThe surface of commercial TiO2 compounds (P25 and ST01) has been modified with Ag nanoparticles induced by radiolysis. On P25, the Ag nanoclusters are very small (1−2 nm) and homogeneous in size while on ST01, two populations of nanoparticles are obtained, small nanoparticles (1−2 nm) and larger ones (mean diameter 7 to 12 nm depending on the silver loading). The photocatalytic properties of Ag-modified TiO2 have been studied for...
-
Ammonium Hydroxide Mediated Hydrothermal Crystallization of Hydroxyapatite Coatings on Titanium Substrate
Publication -
The influence of implantation on mechanical degradation of the nanotubular oxide layer on titanium screws
Publication