dr hab. inż. Stefan Krakowiak
Employment
- Associate professor at Department of Electrochemistry, Corrosion and Materials Engineering
Research fields
Publications
Filters
total: 76
Catalog Publications
Year 2024
-
Vitamin B9 as a new eco-friendly corrosion inhibitor for copper in 3.5% NaCl solution
PublicationFolic acid salt (sodium folate) was studied as an eco-friendly and non-toxic copper corrosion inhibitor in 3.5% NaCl solution. Electrochemical impedance spectroscopy, polarization resistance and weight-loss measurements show that the inhibitor efficiency increases with concentration (the highest value- approx. 96% was reported for the solution containing 16 mM sodium folate after 24 h). EIS data and Tafel plots indicate that sodium...
Year 2022
-
Electrochemical investigations on corosivity of de-icing liquids for railway infrastructure
PublicationThe paper presents the results of electrochemical tests of the de-icing fluid for railway infrastructure. DC and AC electrochemical tests were performed to determine the corrosion rates of structural steel, cast iron and aluminium in the newly produced fluid. The results were compared with the corrosion rates of the same materials in the fluid without corrosion inhibitors. The obtained test results indicate a low corrosion risk...
-
Korozja w środowisku ropy naftowej. Czynniki i monitorowanie
PublicationPrzedstawiono analizy właściwości ropy naftowej z punktu widzenia zawartych w niej czynników korozyjnych oraz ich wpływu na korozję stali w trakcie procesu destylacji ropy naftowej. Krytycznej analizie poddane zostały możliwości oferowane przez współczesne techniki pomiarowe. Wskazano na istotność prowadzenia kompleksowego programu oceny ropy, monitorowania korozji oraz stosowania ochrony inhibitorowej w celu ochrony instalacji...
Year 2021
-
Analysis of the Possibility of Using New Types of Protective Coatings and Abrasion-Resistant Linings under the Operating Conditions of the Spiral Classifier at KGHM Polska Miedź S.A. Ore Concentration Plant
PublicationA study was carried out to select the appropriate coatings for corrosion protection of the spiral classifier working at KGHM Polska Miedź S.A. Ore Concentration Plant. The abrasion resistance of selected protective coatings and wear-resistant linings was investigated using a DT-523 rotary abrasion tester with Taber CS-10 rubber abrasive discs. The average weight loss of the coatings after a cycle of 2000 revolutions was determined....
-
Ekspertyza dotycząca przyczyn pęknięcia rurociągu 8”-096-P1059, zamówienie nr WU/0402/2020/MS
PublicationWykonano badania nieniszczące i niszczących próbek materiału rurociągu wraz z przygotowaniem próbek do badań z materiału rodzimego.
-
Ekspertyza z oceną przyczyn powstania korozji oraz oceną ryzyka obniżenia trwałości kabli sprężenia zewnętrznego konstrukcji nośnej mostu M-4 w ciągu drogi krajowej nr 90 przez rzekę Wisłę koło Kwidzyna
PublicationCelem pracy jest uzyskanie informacji pomocnych do podjęcia właściwej decyzji z punktu widzenia Zarządcy obiektu, co do określenia zakresu niezbędnych działań naprawczych na moście M-4 w ciągu drogi krajowej nr 90 przez rzekę Wisłę koło Kwidzyna, spowodowanych wystąpieniem korozji splotów kabli sprężenia zewnętrznego zlokalizowanego wewnątrz dźwigara skrzynkowego ustroju nośnego przedmiotowego mostu.
Year 2020
-
Określenie przyczyn korozji śrub napędowych ORP Drużno.
PublicationPrzedmiotem ekspertyzy było określenie przyczyn korozji śrub napędowych na okręcie ORP Drużno oraz wskazanie zaleceń odnośnie ograniczenia czynników powodujących ich korozję.
Year 2019
-
Galvanostatic impedance measurements for the efficient adsorption isotherm construction in corrosion inhibitor studies
PublicationWe present an approach towards an accurate and time-efficient adsorption isotherm determination to evaluate the corrosion inhibitor interaction in electrolytic environments. The approach is based on dynamic impedance spectroscopy measurements in galvanostatic mode (g-DEIS). The studied corrosion inhibitor is continuously injected between the secondary cell and the corrosion cell. The efficiency corresponding to instantaneous inhibitor...
-
The Impact of Crushed Rock Spoil on Pitting Corrosion of Selected Stainless Steel
PublicationThe paper presents the results of the pitting resistance investigations of selected stainless steels in the chloride environment and the simultaneous impact of erosive factors using the cyclic polarization technique. Additionally, using electrochemical techniques, ie: electrochemical impedance spectroscopy (EIS) and measurement of corrosion potential, the behavior of the passive layer of selected stainless steels in the environment...
-
Understanding the origin of high corrosion inhibition efficiency of bee products towards aluminium alloys in alkaline environments
PublicationVarious bee products were found to be efficient corrosion inhibitors of aluminium in different environments. In particular, bee pollen was found to be highly effective in alkaline electrolytes, yet its highly complex composition and possible synergistic interactions hinder determination of the compounds acting as active corrosion inhibitors. The main purpose of the following work is to investigate the effect of solvents used for...
Year 2018
-
Carboxylic acids as efficient corrosion inhibitors of aluminium alloys in alkaline media
PublicationThe efficiency of AA5754 aluminium alloy corrosion inhibition achieved with maleic, malic, succinic, tartaric, citric, tricarballylic acids and serine in alkaline environment (pH 11) was examined. Selected corrosion inhibitors are characterized by different numbers and distribution of carbonyl and hydroxyl groups within their molecules. We have proposed and verified a novel approach for determining the adsorption isotherms based...
-
Complex Corrosion Monitoring System for Crude Distillation Unit in Form of Neutral Network
PublicationComplex and successful corrosion monitoring of refinery processes can significantly reduce material losses and failure risk. The developed corrosion monitoring system is based on online ultrasonic sensors, ER (electrical resistance) probes, gravimetric method and multipoint analytical analysis of chemical composition of the fluids. Additional online LPR (linear polarization resistance) sensors controlling corrosiveness of sour...
-
Degradation of protective coatings in steel chimneys of flue gas desulfurisation system
PublicationThis paper presents problems associated with corrosion of steel stacks and changes in philosophy of corrosion protection when implemented into flue gas desulphurization systems. In-situ tests were taken by means of electrochemical impedance spectroscopy at the stack which discharges flue gas before wet lime/limestone desulphurization. A very quick electrolyte absorption by the spherical infill vinylester coating was found using...
-
Ocena przyczyn zniszczenia powłoki ChemLine na zbiorniku 1300T2
PublicationWykonano ekspertyzę związaną z oceną zniszczeń powłoki siloxiranowej na łożonej na powierzchnie wewnętrzne zbiornika magazynowego chlorku metylenu i chlorku etylenu.
Year 2017
-
CORROSION TESTING OF SAMPLES ACCORDING TO ASTM G36
PublicationAt the end of the study, samples were found to have structures characteristic for intercrystalline corrosion. This indicates that the samples provided (fragments of the whole) were sensitized before starting the study in boiling MgCl2.On cross sections, fine cracks are observed on all samples tested.
-
Evaluation of citric acid corrosion inhibition efficiency and passivation kinetics for aluminium alloys in alkaline media by means of dynamic impedance monitoring
PublicationA novel approach is proposed for constructing the adsorption isotherm in corrosion studies, based on a well-known interaction between citric acid and aluminium in alkaline electrolytes. Our approach utilizes the instantaneous impedance measurements via Dynamic Electrochemical Impedance Spectroscopy in galvanostatic mode (g-DEIS). Unlike other common tools, g-DEIS delivers exact information about the concentration required for full...
-
Examination of the epoxy coating system's resistance to Corrobill
PublicationThe tests of the influence of the surface cleaning agent on the epoxy coating were carried out. Electrochemical and corrosion tests were carried out. The effect of the preparation on the adhesion and hardness of the tested coating was tested.
-
Mrówczan sodu z nowym pakietem inhibitorów korozji jako ekologiczny środek do odladzania infrastruktury lotniczej.
PublicationPrzedstawiono wyniki badań korozji kadmowej powłoki na stali oraz korozji po zanurzeniu stopów metali w mrówczanie sodu z nowym pakietem inhibitorów korozji, zawierającym synergiczną kompozycję poliasparaginianu sodu oraz imidazolu. Ponadto wyznaczono zdolność penetracji lodu przez badany układ. Właściwo- ści opracowanej kompozycji odladzającej porównano z właściwościami środków dostępnych na rynku. Uzyskane wyniki wskazują, że otrzymany...
-
Płyny do odladzania i zabezpieczania przed oblodzeniem samolotów, bazujące na trójskładnikowym ekologicznym układzie glikoli propylenowych i glicerolu.
PublicationPrzedstwiono wyniki badań korozji w zanurzeniu stopów metali i korozji9 powłoki kadmowej na stali w nowym płynie do odladzania samolotów (typI) i nowym płynie zapobiegającym ich ponownemu oblodzeniu (typII). Opracowane kompozycje oparto na ekologicznej, trójskładnikowej mieszaninie glikolu 1,2-propylenowego, 1,3-propylenowego oraz glicerolu.
-
Wykonanie oceny stanu wykładziny chemoodpornej wieży Absorbcyjnej T102 Solinox
PublicationPrzeprowadzono szczegółowe badania wykładziny chroniącej wewnętrzną częśc absorbera SO2. Na podstawie wykonanych badań i pomiarów zaproponowano alternatywne metody poprawy jakosci wykładziny.
Year 2016
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublicationCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...
-
Effect of Thermal Shock During Legionella Bacteria Removal on the Corrosion Properties of Zinc-Coated Steel Pipes
PublicationThe purpose of this investigation was to conduct the failure analysis of a water-supply system made from zinc-coated steel. The observed corrosion process had an intense and complex character. The brownish deposits and perforations were present after 2-3 years of exploitation. The electrochemical study based on the Tafel polarization, corrosion potential monitoring, and electrochemical impedance spectroscopy together with microscopic...
-
Electrolytic corrosion of water pipeline system in the remote distance from stray currents– case study
PublicationCase study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800 ÷ 1,000 meters from the point of failure. At the point of failure stray currents flowed from the pipeline...
-
Investigation of the electrochemical behaviour of AA1050 aluminium alloy in aqueous alkaline solutions using Dynamic Electrochemical Impedance Spectroscopy
PublicationThe paper presents the electrochemical behaviour of aluminium alloy AA1050 in aqueous alkaline media in the pH range 14–8.5. Electrochemical study was applied in order to obtain comprehensive information on the mechanism and kinetics of the process of anodic dissolution of aluminium, supplemented by monitoring of surface topography using an electron microscope. The corrosion rate of AA1050 increases with increasing concentration...
-
Microstructure and corrosion behaviour of carbon steel and ferritic and austenitic stainless steels in NaCl solutions and the effect of p-nitrophenyl phosphate disodium salt
PublicationThe microstructure and corrosion behavior of carbon steel (CSA516) and ferritic (SS410) and austenitic (SS304L) stainless steels were studied and compared. Corrosion tests were carried out in 0.5 M NaCl solutions. Rates of corrosion were monitored based on weight loss, Tafel extrapolation and linear polarization resistance (LPR) methods. Rates of corrosion were ranked following the order: CSA516 >> SS410 > SS304L. The impact of...
-
Research on causes of corrosion in the municipal water supply system
PublicationThis paper presents results of failure analysis study to characterize the corrosion damage that occurred in the water supply system in Krakow. This analysis includes: electrochemical noise, linear polarization and resistometric measurements. Water aggressiveness of four water intakes was defined using Langelier and Ryznar indices. Results from this indices did not reveal the causes of considerable corrosion losses in water systems....
Year 2015
-
Assessment of protective properties of rubber lining in absorbers of flue gas desulphurization systems.
PublicationResults of research on degradation of rubber lining which is the main protection of absorbers in flue gas desulphurization (FGD) systems were presented. The power plant where the system operated is lignite-fired. Owing to measurements using electrochemical impedance spectroscopy and gravimetric determination of water content in the lining, the areas of the system which are most exposed to degradation were shown. The results obtained...
-
Instantaneous impedance monitoring of AA 7075 aluminum alloy corrosion in borate buffer with admixed chloride ions
PublicationThe study presents a research capabilities of Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a tool used for instantaneous on-line monitoring of corrosion processes on the example of AA 7075 aluminum alloy. A borate buffer with admixed chloride ions in a quantity ranging from 0.05 to 25 mM was used to represent different types of corrosion attack. The surface of samples specimens was evaluated before and after the tests...
-
Zagrożenia korozyjne stali nierdzewnych w przemyśle spozywczym
PublicationPrzedstawiono przyczyny występowania zagrożeń korozyjnych stali nierdzewnych w przemyśle spożywczym. Szczegółowo omówiono mechanizm oraz sposób zapobiegania korozji wżerowej, szczelinowej oraz pękania korozyjnego. Zaprezentowano dokumentację fotograficzną omówionych typów korozji. Wskazano podstawowe problemy związane z doborem materiałów konstrukcyjnych do budowy instalacji w przemyśle spożywczym.
Year 2014
-
EVALUATION OF CAUSES OF CORROSION OF PLATE HEATEXCHANGER
PublicationPrzeprowadzono analizę zniszczeń korozyjnych wykrytych na płycie wymiennika ciepła stosowanego do chłodzenia silnika głównego statku. Stwierdzono obecność wżerów korozyjnych oraz korozji szczelinowej. Przedstawiono możliwe przyczyny wystąpienia w.w. uszkodzeń.
-
PROBLEMS WITH CORROSION PROTECTION STEEL STACKS IN FGD SYSTEMS
PublicationThis paper presents problems associated with corrosion of steel stacks and changes in philosophy of corrosion protection when implemented into flue gas desulphurization systems. In-situ tests were taken by means of electrochemical impedance spectroscopy at a stack which discharges flue gas before wet lime/limestone desulphurization. A very rapid soaking of spherical infill vinylester coating with electrolyte has been observed....
-
WYKONANIE BADAŃ I POMIARÓW POWŁOK ANTYKOROZYJNYCH ZABEZPIECZAJĄCYCH ELEMENTY METALOWE KONSTRUKCJI STALOWYCH, APARATÓW I URZĄDZEŃ INSTALACJI ODZYSKU OPARÓW BENZYN W BAZIE PALIW GRUPY LOTOS S.A. w POZNANIU
PublicationPrzeprowadzono inspekcję powłok malarskich na konstrukcji odzysku oparów w bazie Paliw Płynnych Grupy Lotos. Na podstawie wyników inspekcji przedstawiono wnioski i zalecenia związane ze stanem powłok i ich ewentualną naprawą.
-
Zbadanie środowiska korozyjnego oraz jego wpływu na rozkład, wielkość i głębokość wżerów korozyjnych rur.
PublicationPrzedstawiono wyniki oceny wizualnej rurociągów składowanych w okolicy Warszawy. Stwierdzono występowanie korozji galwanicznej w wyniku tworzenia się ogniw zmiennego napowietrzenia. Obserwacje poparto badaniami laboratoryjnymi.
Year 2013
-
ANALIZA STANU TECHNICZNEGO RUROCIĄGÓW: WODY PRZeMYSŁOWEJ I SOLANKI
PublicationPracę wykonano na zlecenie Przedsiębiorstwa Badawczo-Wdrożeniowego "HYDRO-POMP" Sp. z o.o. ul. Wróblewskiego 19, 93-578 Łódź. Wykonawcą zlecenia jest Politechnika Gdańska, Wydział Chemiczny, Katedra Elektrochemii, Korozji i Inżynierii Materiałowej, 80-233 Gdańsk, ul. G. Narutowicza 11/12. Celem pracy była analiza stanu technicznego i badania dwóch rurociągów: solanki oraz wody przemysłowej. Badania wykonywano w warunkach terenowych...
-
Badanie przyczyn korozji skraplaczy aluminiowych.
PublicationPrzeprowadzono badania aluminiowych skraplaczy pracujących w układach chłodzenia tramwajów. Stwierdzono, że problemy z korozją są wynikiem stosowania środków myjących o właściwościach korozyjnych w stosunku do zastosowanego aluminium.
-
Badanie przyczyn korozji zbiorników magazynowych na paliwa na terenie stacji benzynowej grupy Lotos w Pruszkowie
PublicationPrzedstawiono wyniki oględzin zbiornika na olej napędowy eksploatowany na stacji benzynowej w Pruszkowie. Przedstawiono możliwe przyczyny powstania zniszczeń korozyjnych w dolnej części zbiornika.
-
BADANIE REAKTYWNOŚCI CZYNNIKA ORGANICZNEGO W STOSUNKU DO WYBRANYCH STOPÓW
PublicationPrzeprowadzono badanie odporności korozyjnej stali konstrukcyjnej zwykłej jakosci, stali ferrytycznej oraz stopu łozyskowego i próbek uszczelnienia gumowego na działanie oleju silikonowego o sciśle zdefiniowanych właściwościach fizyko-chemicznych. Stwierdzono praktycznie brak znaczących ubytków korozyjnych przekazanych do badań materiałów.
-
EVALUATION OF CAUSES OF CORROSION OF HEATING PIPES AND BALLAST CHAMBERS ON HLVJ INNOVATION
Publication..
-
Ocena właściwości ochronnych preparatu Tectyl 477D oraz preparatu SteelRed
Publication..
-
Opinia dotycząca zagrożenia korozyjnego zbiorników wody ciepłej na terenie warzelni browaru w Białymstoku
PublicationStwierdzono występowanie pęknięć w zbiorniku wody ciepłej procesowej w browarze w Białymstoku. Propagacja pęknięć ma miejsce w obrębie spawu. Wykonano niezbędne badania, oraz zaproponowano metodę ochrony zbiornika przed dalszym rozwojem korozji naprężeniowej.
-
Pitting corrosion and stress-corrosion cracking of buffer tanks in a brewery
PublicationW pracy przedstawiono wyniki ekspertyzy zbiornika magazynowego na ciepłą wodę do produkcji piwa w browarze. Zbiornik uległ przyśpieszonym procesom korozyjnym, które doprowadziły do jego perforacji. Podczas eksploatacji zbiornika wystąpił proces korozji wżerowej oraz pękania korozyjnego. Przyśpieszone procesy korozyjne zbiornika związane były z wysoką zawartością jonów chlorkowych w wodzie oraz statycznymi naprężeniami mechanicznymi....
Year 2012
-
Cyclic analysis of thermal impedance of a passive layer of aluminium in a neutral borate buffer solution
PublicationW pracy przedstawiono wyniki badań warstwy pasywnej tworzącej się na stopie 1050 A w warunkach zmieniającej się temperatury. Zmiany realizowano w sposób cykliczny zwiększając a następnie zmniejszając temperaturę. W czasie zmian temperatury prowadzono badania metodę dynamicznej elektrochemicznej spektroskopii impedancyjnej. Stwierdzono największe zmiany parametrów elektrycznego schematu zastępczego w czasie pierwszego cyklu zmian....
-
Pasywacja stali nierdzewnych
Publication -
Pasywacja stali nierdzewnych
PublicationOdporność chemiczna stali odpornych na korozję oparta jest calkowicie na pasywnym charakterze warstw powierzchniowych istniejących na tych stalach. Pasywność to stan, w którym metal aktywny wykazuje podwyższoną odporność korozyjną dzięki tworzeniu na powierzchni warstewki, która jest stabilna w danym środowisku, pH i potencjale oraz stanowi produkt korozji.
Year 2011
-
Badania procesu trawienia stali wysokostopowej za pomocą spektroskopii impedancyjnej
PublicationPrzeprowadzono badania trawienia stali wysokostopowej w mieszaninie kwasu HF IHNO3 wykorzystując elektrochemiczna spektroskopie impedancyjną. W celu odwzorowania warunków naturalnych eksperyment przeprowadzono przy uzyciu DEIS w trybie galwanostatycznym z wypadkowym prądem równym zero. Wyznaczone zostały zmiany parametrów elektrycznych opisujących układ ew czasie zmian. Zaobserwowano wpływ stężenia HF na czas trwania procesu.
-
Emisja akustyczna podczas korozji stopów na bazie metali lekkich
PublicationPrzedstawiono wyniki badań elektrochemicznych metodą polaryzacji cyklicznej oraz emisji akustycznej technicznie czystego aluminium(stop1050) oraz magnezu. W przypadku aluminium aktywność akustyczna jest związana z inicjacją i wzrostem wżerów. Aktywność akustyczna magnezu występuje w obszarze inicjacji i wzrostu wżerów oraz w czasie repasywacji wżerów.
-
Zwiększenie odporności stali austenitycznych poprzez obróbkę chemiczna powierzchni
PublicationPrzedstawiono wyniki badań elektrochemicznych stali stopowej 1.4301 w środowisku korozyjnym zawierającym jony chlorkowe. Powierzchnia stali została poddana przed badaniami różnym typom obróbki powierzchniowej. Porównano odporność na korozję wżerową stali poddanej trawieniu, trawieniu i pasywacji oraz samej pasywacji. Stwierdzono poprawę odporności stali poddanej dodatkowej obróbce powierzchniowej w stosunku do stali przygotowanej...
Year 2010
-
Corrosion resistance evaluation of Al-based alloys by means of dynamic electrochemical impedance spectroscopy
PublicationW pracy przedstawiono wyniki badań stopów aluminium wykonane za pomocą dynamicznej elektrochemicznej spektroskopii. Na podstawie uzyskanych widm impedancyjnych zostały pokazane zmiany parametrów elektrycznego schematu zastępczego z potencjałem. Stwierdzono, że dodatek magnezu do badanego stopu obniża właściwości przeciwkorozyjne stopu.
-
Wpływ zawartości jonów chlorkowych w brzeczce i piwie na korozję wżerową instalacji browarniczych
PublicationPrzedstawiono wyniki badań wpływu zawartości jonów chlorkowych w piwie na zagrożenie korozja wżerową stali stopowej. Badania wskazują, że wzrost stężenia jonów chlorkowych zwiększa zagrożenie korozją wżerową, występuje brak prostej korelacji pomiędzy zawartością jonów chlorkowych a podatnością stali na korozję.
Year 2009
-
Electrochemical and acoustic emission studies of aluminium pitting corrosion
PublicationBadania metodą potencjokinetyczną i emisjii akustycznej przeprowadzono w typowej trójelektrodowej celce elektrochemicznej. Elektrodę badaną przygotowano z stopu aluminium 1050A. Badania metodą cyklicznej polaryzacji i emisjii akustycznej wykonywano jednocześnie. Na podstawie wyników akustycznych i polaryzacyjnych wyznaczono potencjał korozji wzerowej.
seen 3064 times