prof. dr hab. inż. Zbigniew Lubośny
Employment
- Professor at Department of Electrical Power Engineering
Publications
Filters
total: 138
Catalog Publications
Year 2015
-
Effectiveness of the robust PSS design
PublicationThe paper discusses optimal PSS of synchronous generator synthesis. The optimal controller is an Hinf controller, what means that minimises Hinf norm of transfer function between the exogenous signals such as reference inputs and disturbances, and the error signals which are to be minimised to meet the control objective. The dynamic properties of the plant are shaped by choosing appropriate weighting function applied to the plant...
-
EHV transmission lines wires location on line operation issues - case studies
PublicationTransmission lines towers construction affects the line parameters and influences on its operation in the future. Misguided design of the tower can lead to serious problems such as overvoltages, electric arc extinction difficulties, voltage asymmetry, resonance phenomena or increasing of magnetic field near the line. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors....
-
Ekspertyza : Mapa rozwoju dyscypliny Elektrotechnika : Systemy Elektroenergetyczne
PublicationW publikacji przedstawiono trendy rozwojowe dyscypliny elektrotechnika opracowanej przez Komitet Elektrotechniki PAN.
-
Fractional-order Systems and Synchronous Generator Voltage Regulator
PublicationModern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using...
-
Induced sheath voltages in 110 kV power cables – case study
PublicationThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Influence of Shunt Compensation with SVC Devices on Resonance Risk in Power Systems
PublicationMany analyses are required to locate a new reactive power source in a power system. The choice of a location is a very complex matter which requires various aspects to be considered. Selecting a location also entails the necessity to assess it from the point of view of the selected compensator’s structure as well as the system’s performance in various states with the new device on. The paper presents the issues of assessing compensator...
-
Nonlinear secondary arc model use for evaluation of single pole auto-reclosing effectiveness
PublicationPurpose – The purpose of this paper is to discuss two evaluation methods of single pole autoreclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc implementation is presented. Design/methodology/approach – A computer simulation studies were...
-
Obliczanie rozpływu prądów zwarciowych w przewodach odgromowych linii WN
PublicationW referacie przedstawiono metodę oraz jej implementację w postaci programu komputerowego, które umożliwiają obliczenie rozpływu prądów zwarciowych w linkach odgromowych linii wysokiego napięcia. Algorytm umożliwia obliczenia dla linii dwustronne zasilanej oraz linii w układzie gwiazdowym (z odczepem). Opracowany program umożliwia weryfikację doboru przewodów odgromowych z punktu widzenia wytrzymałości zwarciowej cieplnej.
-
Obliczenia rozpływu prądów zwarciowych w przewodach odgromowych linii WN
PublicationW artykule przedstawiono metodę oraz jej implementację w postaci programu komputerowego, które umożliwiają obliczenie rozpływu prądów zwarciowych w linkach odgromowych linii wysokiego napięcia. Algorytm umożliwia obliczenia dla linii dwustronnie zasilanej oraz linii w układzie gwiazdowym (z odczepem). Opracowany program umożliwia weryfikację doboru przewodów odgromowych z punktu widzenia wytrzymałości zwarciowej cieplnej.
-
Problematyka doboru zabezpieczeń dławików kompensacyjnych pracujących w sieciach najwyższych napięć
PublicationW artykule przedstawiono trudności, jakie napotyka się podczas projektowania systemu zabezpieczeń dla dławików przyłączanych bezpośrednio do sieci najwyższych napięć (NN). Bazując na przykładzie budowanej aktualnie stacji 400 kV Ełk Bis, pokazano, że możliwości zabezpieczenia dławika, oparte na układach EAZ wykorzystujących pomiary sygnałów elektrycznych z przekładników prądowych i napięciowych, mają swoje ograniczenia i w pewnych...
-
Problematyka kompensacji mocy biernej linii elektroenergetycznych wysokiego napięcia
PublicationW artykule przedstawiono rozważania dotyczące doboru dławików kompensacyjnych dla linii elektroenergetycznej dwutorowej wysokiego napięcia 400 kV, na przykładzie nowo budowanej linii Ełk Bis – Alytus. W analizach uwzględniono różne stany pracy układu. Zamieszczone wyniki dotyczą poziomów napięć w stanach ustalonych, podczas procesów łączeniowych oraz zwarć.
-
Projektowanie i efektywność stabilizatora systemowego minimalizującego normę Hinf.
PublicationArtykuł opisuje możliwości syntezy krzepkiego stabilizatora systemowego minimalizującego normę Hinf, którego właściwości dynamiczne kształtowane są przez wybór odpowiedniej funkcji wagowej. Rozważana jest efektywność metody w procesie projektowania stabilizatora systemowego.
-
Secondary arc modelling for single pole reclosing analyses
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage calculation results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc model implementation is presented. The paper presents the study results for the three types of EHV transmission...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublicationThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
Wybrane problemy doboru zabezpieczeń dławików kompensacyjnych pracujących w sieciach najwyższych napięć
PublicationW referacie przedstawiono trudności jakie napotyka się podczas projektowania systemu zabezpieczeń dla dławików przyłączanych bezpośrednio do sieci najwyższych napięć (NN). Referat, bazując na przykładzie budowanej aktualnie stacji 400 kV Ełk Bis, pokazuje, że możliwości zabezpieczenia dławika, oparte na układach EAZ wykorzystujących pomiary sygnałów elektrycznych z przekładników prądowych i napięciowych mają swoje ograniczenia...
-
Wybrane problemy kompensacji mocy biernej linii elektroenergetycznej wysokiego napięcia
PublicationW artykule przedstawiono rozważania dotyczące doboru dławików kompensacyjnych dla linii elektroenergetycznej dwutorowej wysokiego napięcia 400 kV, na przykładzie nowobudowanej linii Ełk Bis-Alytus . W analizach uwzględniono różne stany pracy układu. Zamieszczone wyniki dotyczą poziomów napięć w stanach ustalonych, podczas procesów łączeniowych oraz zwarć.
Year 2014
-
Badanie działania sterownika telemechaniki z funkcją sygnalizatora zwarć w wykorzystaniem modelu referencyjnego sieci SN
PublicationPrzedmiotem opracowania jest analiza działania sterownika telemechaniki STGP-3 z funkcją sygnalizatora zwarć opracowanego przez Instytut Energetyki Oddział Gdańsk. Badania sterownika przeprowadzono w laboratorium Elektroenergetycznej Automatyki Zabezpieczeniowej Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej.
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublicationThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublicationMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Detection of high frequency current components by residual current devices
PublicationThe negative impact of current harmonics on the main components of residual current devices is presented. A solution for the improvement of the operation of residual current devices is proposed.
-
Elektroenergetyczna automatyka zabezpieczeniowa farm wiatrowych
PublicationKsiążka prezentuje zagadnienia związane z elektroenergetyczną automatyką zabezpieczeniową farm wiatrowych. Przedstawiono zasady doboru zabezpieczeń sieci farmy wiatrowej (w tym przekładników zabezpieczeniowych) oraz elementów systemu elektroenergetycznego przylegających do farmy wiatrowej. Rozważania powyższe poparto przykładem doboru zabezpieczeń, nastaw zabezpieczeń, przekładników prądowych i napięciowych zabezpieczeniowych dla...
-
Estimation of Selected Synchronous Generator Parameters Based on the Gradient Method
PublicationThe authors present a method for the estimation of synchronous generator model parameters using a gradient algorithm. The paper shows an example of model parameter estimation for a turbogenerator and hydrogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test.
-
Evaluation Of Single Pole Auto-Reclosing Effectiveness With Nonlinear Secondary Arc Model
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a non-linear secondary arc implementation is presented. The authors indicate, that precise representation of secondary electric arc leads to more...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublicationThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Proposition of the steam turbine governor structure modification
PublicationThere is considered the steam turbine governor operation during defense and restoration of the power system. It points out weaknesses of currently used governor structures. The new controller is proposed, that takes advantages of those curently used. The new controller allows for more effective control of the turbine in emergency situations, at frequencies much different from the nominal value.
-
Uzupełnienie klasycznego modelu matematycznego generatora synchronicznego
PublicationW artykule przedstawiono wyprowadzenie zależności matematycznych prowadzących do uzupełnienia tzw. klasycznego modelu matematycznego generatora synchronicznego typu generator – sieć sztywna, o możliwość obliczania transmitancji zakłóceniowej. Model ten zweryfikowano przez porównanie z modelem generator-sieć sztywna z modelem generatora 7-go rzędu.
-
Warunek zwarciowy SkQ/Sn>=20 ograniczeniem rozwoju OZE
PublicationW referacie omówiono zagadnienia związane z warunkiem zwarciowym, czyli ilorazem mocy zwarciowej w rozpatrywanym miejscu przyłączenia do sieci elektroenergetycznej źródła energii i mocy znamionowej tego źródła. Wskazano jego pochodzenie oraz przedyskutowano zasadność jego stosowania w analizach przyłączeniowych.
-
Wpływ odnawialnych źródeł generacji energii na bezpieczeństwo pracy krajowego systemu elektroenergetycznego
PublicationW referacie omówiono ogólne problemy związane z rozwojem systemów elektroenergetycznych, w tym związane z tzw. źródłami energii odnawialnej (OZE). Na tym tle przedstawiono zagadnienia związane z bezpieczeństwem energetycznym, wpływem OZE na bezpieczeństwo i dalej zagadnienia związane z kierunkami rozwoju systemów elektroenergetycznych.
-
Zastosowanie gramianów w automatyce APKO
PublicationPrzedstawiono zastosowanie gramianów do oceny zapasu stabilności systemu elektroenergetycznego. Zaproponowano układ regulacji turbiny w postaci Automatyki Przeciw-Kołysaniowo Odciążającej (APKO) do ochrony turbozespołu wytwórczego przed utratą stabilności.
Year 2013
-
Estymacja wybranych parametrów modelu generatora synchronicznego z wykorzystaniem metody gradientowej rozmytej – referat konferencyjny
PublicationReferat prezentuje metodę estymacji parametrów modelu generatora synchronicznego z wykorzystaniem algorytmu gradientowego. Przedstawiono przykład estymacji parametrów modelu hydrogeneratora w oparciu o przebiegi napięcia generatora podczas dwóch testów: zrzutu mocy czynnej i zrzutu mocy biernej. Prezentowane analizy zostały wykonane w autorskim programie wykorzystującym środowisko modelowania PowerFactory firmy DIgSILENT.
-
Interior Point Method Evaluation for Reactive Power Flow Optimization in the Power System
PublicationThe paper verifies the performance of an interior point method in reactive power flow optimization in the power system. The study was conducted on a 28 node CIGRE system, using the interior point method optimization procedures implemented in Power Factory software.
-
Koncepcja przyłączenia elektrowni fotowoltaicznej na terenie działki nr 43 obręb 2 Nowy Staw do istniejącej sieci
PublicationW Pracy przedstawiono wstępną koncepcję przyłączenia elektrowni fotowoltaicznej do sieci średniego napięcia na terenie gminy Nowy Staw.
-
Ocena możliwości wykorzystania metody punktu wewnętrznego do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym – referat konferencyjny.
PublicationW referacie poddano weryfikacji metodę punktu wewnętrznego pod kątem jej wykorzystania do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym. Rozważania przeprowadzono na 28 węzłowym systemie CIGRE, z wykorzystaniem zaimplementowanej metody punktu wewnętrznego w programie PowerFactory firmy DIgSILENT.
-
Optymalizacja poziomów napięć i rozpływów mocy biernej w systemie elektroenergetycznym z wykorzystaniem logiki rozmytej – referat konferencyjny
PublicationReferat prezentuje zagadnienia związane ze sterowaniem poziomami napięć w systemie elektroenergetycznym. Rozważana jest autorska metody optymalizacji rozpływu mocy biernej, prowadząca do poprawy warunków napięciowych w systemie elektroenergetycznym i ograniczenia strat mocy czynnej. Opracowana metoda optymalizacyjna bazuje na procedurze opartej o logikę rozmytą, wspomaganej algorytmem gradientowym. Metoda została zaimplementowana...
-
Start-up of a power unit of a thermal power plant auxiliary systems with supply from a hydropower plant
PublicationThis article discusses the issues related to a power unit of a thermal power plant start-up with the use of a hydropower plant. Hydropower plant can supply and will enable start-up of auxiliary equipment in a power unit of a thermal power plant. Due to high capacity of auxiliary drives, start-up of auxiliaries in a thermal power plant after blackout (and boiler shutdown) is not possible from emergency energy sources in the power...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublicationThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
VSC converters control for offshore wind farms HVDC grid connection
PublicationThe paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.
Year 2012
-
A Paradigm for HV, MV, LV Distribution Grid Development Planning
PublicationIn the literature, including that relating to businesses in the energy (and power) sector, the concept of these organizations’ operating paradigm may be found. The paper discusses the concept of the paradigm, with a focus on the power grid development planning paradigm. Against this background, issues related to energy security and power systems development trends and problems are presented. A new paradigm is proposed for distribution...
-
Optymalizacja rozpływów mocy biernej w systemie elektroenergetycznym
PublicationReferat prezentuje zagadnienia związane ze sterowaniem poziomami napięć w systemie elektroenergetycznym. Rozważane są dwie metody optymalizacji rozpływu mocy biernej, prowadzące do poprawy warunków napięciowych w systemie elektroenergetycznym i ograniczenia strat mocy czynnej. Pierwsza z metod optymalizacyjnych poddanych weryfikacji została zaimplementowana w programie PLANS, a bazuje na autorskiej procedurze opartej o logikę rozmytą,...
-
Propozycja modyfikacji struktury regulatorów turbin parowych
PublicationReferat podejmuje tematykę wpływu struktury regulatora turbiny na proces obrony i odbudowy systemu elektroenergetycznego. Wskazując niedoskonałości obecnie stosowanych regulatorów zaproponowano autorską strukturę regulatora turbiny parowej. Nowy regulator wykorzystuje zalety stosowanych obecnie regulatorów mocy z korektą od częstotliwości, pozwalając jednocześnie na efektywniejsze sterowanie turbinami w stanach awaryjnych, przy...
-
Steam turbines governors in power system restoration process
PublicationThe paper discusses problems related to electric power system restoration process. The turbine controller operating mode influence in small subsystem is analyzed. There are considered abilities, advantages and drawbacks of the controller's two operating modes: power control and speed (frequen-cy) control, to rebuild electric power system from a single generating unit to a few parallel running generators.
-
Weryfikacja działania blokad przeciwkołysaniowych na przykładzie zabezpieczeń firmy Siemens
PublicationReferat podejmuje tematykę działania zabezpieczeń impedancyjnych w czasie trwania synchronicznych i asynchronicznych kołysań mocy. W referacie analizowano działanie zabezpieczeń impedancyjnych generatora synchronicznego oraz linii blokowej. Wskazano na niebezpieczeństwo błędnego działania zabezpieczeń przy obecnie stosowanych sposobach ich nastawiania.
-
Weryfikacja nastawień zabezpieczeń od utraty wzbudzenia na przykładzie elektrociepłowni przemysłowej
PublicationW artykule przedstawiono rozważania dotyczące działania zabezpieczeń reaktancyjnych od utraty wzbudzenia generatorów synchronicznych, pracujących w elektrociepłowni przemysłowej. Pokazano możliwości niewłaściwego działania zabezpieczenia od utraty wzbudzenia, wskazując że dobór nastawień powinien każdorazowo wykorzystywać badania modelowe. Przyjmowanie nastawień typowych zgodnych z wiedzą inżynierską może być przyczyną niewłaściwego...
-
Zabezpieczenia elektroenergetyczne bloku w początkowym okresie odbudowy systemu po blackoucie
PublicationOmówiono etapy przechodzenia bloku elektroenergetycznego z pracy na potrzeby własne do pracy na sieć wydzieloną w procesie odbudowy systemu. Przedstawiono wymagane zabezpieczenia, które powinny chronić poszczególne elementy systemu elektroenergtycznego w poszczególnych etapach tego procesu. Przedstawiono wymagania dotyczące charakterystyk zabezpeiczenia reagującego na utratę synchronizmu wzbudzonego generatora w warunkach pracy...
-
Zabezpieczenia elektroenergetyczne bloku w początkowym okresie odbudowy systemu po blekaucie
PublicationOmówiono etapy przechodzenia bloku elektroenergetycznego z pracy na potrzeby własne do pracy na sieć wydzieloną w procesie odbudowy systemu. Przedstawiono wymagane zabezpieczenia, które powinny chronić poszczególne elementy systemu elektroenergtycznego w poszczególnych etapach tego procesu. Przedstawiono wymagania dotyczące charakterystyk zabezpeiczenia reagującego na utratę synchronizmu wzbudzonego generatora w warunkach pracy...
Year 2011
-
Application capabilities of the maximum distributed generation estimate methodology
PublicationThe paper presents application capabilities of the maximum distributed generation estimate methodology. This subject is an example of solutions to the problem that today face the transmission system operator and distribution system operators, which is related to the high saturation with wind power generation predicted for the near future.
-
Możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej
PublicationW referacie przedstawiono możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej. Temat ten jest jednym z przykładowych rozwiązań problemu, który stoi dzisiaj przed operatorami systemów dystrybucyjnych, a związany jest z prognozowanym dużym nasyceniem energetyką wiatrową w najbliższych latach.
-
Możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej
PublicationW artykule przedstawiono możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej. Temat ten jest jednym z przykładowych rozwiązań problemu, który stoi dzisiaj przed operatorem systemu przesyłowego oraz przed operatorami systemów dystrybucyjnych, a związany jest z prognozowanym dużym nasyceniem energetyką wiatrową w najbliższych latach.
-
The impact of wind farms with fixed speed induction generators on grid damping in Northern Ireland
Publication
seen 4526 times