dr inż. Adam Mazikowski
Zatrudnienie
- Adiunkt w Katedra Metrologii i Optoelektroniki
Publikacje
Filtry
wszystkich: 46
Katalog Publikacji
Rok 2024
-
Extra-curricular project-oriented education in optoelectronics in the Faculty of Electronics, Telecommunications and Informatics at Gdańsk University of Technology, Poland
PublikacjaProject-oriented education constitutes a key part of the curriculum in the Faculty of Electronics, Telecommunications and Informatics of Gdańsk University of Technology (Gdańsk Tech), Poland. Students on the Engineer and Master of Science level studies take part in several projects, both individually and in teams. In addition to compulsory activities, students have the opportunity to take part in the activities of student scientific...
Rok 2023
-
16-kanałowy moduł LED do systemu wspomagającego rozwój roślin sterowany za pomocą Raspberry PI
PublikacjaOpracowywane są nowe rozkłady widma światła, które wpływają na poprawę zarówno ilości plonów i jakości dokonywanych zbiorów. W celu uproszczenia wprowadzania zmian widma w procesach badawczych oraz w celu przyspieszenia i zrównoleglenia badań w tym zakresie został opracowany niedrogi programowalny moduł LED pozwalający sterować 16 niezależnymi stałoprądowymi kanałami. Niska cena proponowanego rozwiązania oraz jeden sterownik obsługujący...
Rok 2021
-
Examination of Spectral Properties of Medicinal Plant Leaves Grown in Different Lighting Conditions Based on Mint Cultivation
PublikacjaCultivation in controlled environmental conditions can provide good quality medicinal herbs with consistent properties. A sensing system that can determine the contents of medicinal substances in plants using spectral characteristics of leaves would be a valuable tool. Viability of such sensing approach for mint had to be confirmed experimentally, as no data correlating contents of medicinal substances with spectral characteristics...
-
Multiuser Stereoscopic Projection Techniques for CAVE-Type Virtual Reality Systems
PublikacjaDespite the development of increasingly popular head mounted displays, CAVE-type systems may still be considered one of the most immersive virtual reality systems with many advantages. However, a serious limitation of most CAVE-type systems is the generation of a three-dimensional (3-D) image from the perspective of only one person. This problem is significant because in some applications, the participants must cooperate with each...
-
QUASI-DISTRIBUTED NETWORK OF LOW-COHERENCE FIBER-OPTIC FABRY-PÉROT SENSORS WITH CAVITY LENGTH-BASED ADDRESSING
PublikacjaDistributed measurement often relies on sensor networks. In this paper, we present the construction of low coherent fiber-optic Fabry-Pérot sensors connected into a quasi-distributed network. We discuss the mechanism of spectrum modulation in this type of sensor and the constraints of assembly of such sensors in the network. Particular attention was paid to separate the signals from individual sensors, which can be achieved by...
Rok 2020
-
Formation of the hollow nanopillar arrays through the laser-induced transformation of TiO2 nanotubes
PublikacjaIn the following article, we present a simple, two-step method of creating spaced, hollow nanopillars, from the titania nanotube arrays via pulsed laser-treatment. Due to the high ordering of the structure, the prepared material exhibits photonic properties, which has been shown to increase the overall photoefficiency. The optical and morphological changes in the titania nanotubes after pulsed laser-treatment with 532, 355, and...
Rok 2019
-
A Measurement System for Quasi-Spectral Determination of Absorption and Scattering Parameters of Veterinary Tissue Phantoms
PublikacjaThis paper describes the construction of a system for the quasi-spectral determination of absorption and scattering parameters of animal tissue phantoms. Several tissue phantoms, including one reference and two modified for examination, were prepared from polydimethylsiloxane (PDMS). The phantoms were measured using a system based on an integrating sphere and the light sources of wavelengths commonly used for the treatment of various...
-
Analiza efektywności systemów oświetlania roślin na przykładzie uprawy bazylii
Publikacja -
Analiza efektywności systemów oświetlania roślin na przykładzie uprawy bazylii
PublikacjaDynamiczny rozwój technologii LED oraz znaczące podwyżki cen energii elektrycznej wymuszają badania mające na celu zwiększenie efektywności systemów oświetleniowych do uprawy roślin. W pracy przeprowadzono analizę efektywności oświetlenia na przykładzie uprawy bazylii. Na wstępie dokonano pomiarów spektralnych liści bazylii. Na podstawie otrzymanych wyników opracowano i wykonano oświetlenie dopasowane do charakterystyki spektralnej...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublikacjaIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
Investigation of optical properties of Infitec and Active Stereo stereoscopic techniques for CAVE-type virtual reality systems
PublikacjaIn recent years, many scientific and industrial centres in the world developed virtual reality systems or laboratories. At present, among the most advanced virtual reality systems are CAVE-type (Cave Automatic Virtual Environment) installations. Such systems usually consist of four, five, or six projection screens arranged in the form of a closed or hemi-closed space. The basic task of such systems is to ensure the effect of user...
Rok 2018
-
Analysis of luminance distribution uniformity in CAVE-type virtual reality systems
PublikacjaIn recent years, many scientific and industrial centers in the world developed a virtual reality systems or laboratories. The effect of user “immersion” into virtual reality in such systems is largely dependent of optical properties of the system. In this paper, problems of luminance distribution uniformity in CAVE-type virtual reality systems are analyzed. For better characterization of CAVE luminance nonuniformity corner and...
-
Automatic system for optical parameters measurements of biological tissues
PublikacjaIn this paper a system allowing execution of automatic measurements of optical parameters of scattering materials in an efficient and accurate manner is proposed and described. The system is designed especially for measurements of biological tissues including phantoms, which closely imitate optical characteristics of real tissue. The system has modular construction and is based on the ISEL system, luminance and color meter and...
-
Comparison of modelling and measurement results of spectra emitted by a programmable lamp
PublikacjaNowadays artificial light with an optimized spectrum is used in many different applications. For instance, it is widely used in museums and exhibitions to illuminate the art. Moreover, such light stimulates the growth of plants, or can be applied in industry and healthcare. To achieve the best results for each application, the adjusting of a dedicated spectrum is required, which is a complicated task. The ongoing research is focused...
Rok 2017
-
DESIGN THINKING ORIENTED METHODOLOGY IN GROUP PROJECT AS A STEP IN THE CDIO APPROACH
PublikacjaRecently much scientific research and industrial work is conducted in multidisciplinary teams, where cooperation between specialists from different areas of expertise is required in order to successfully address the challenging goals. Moreover, in start-up small companies the lack of supporting departments calls for additional multidisciplinary, economic and networking skills known as T-shaped personality. Recognizing these shortcomings...
-
Investigation of tracking systems properties in CAVE-type virtual reality systems
PublikacjaIn recent years, many scientific and industrial centers in the world developed a virtual reality systems or laboratories. One of the most advanced solutions are Immersive 3D Visualization Lab (I3DVL), a CAVE-type (Cave Automatic Virtual Environment) laboratory. It contains two CAVE-type installations: six-screen installation arranged in a form of a cube, and four-screen installation, a simplified version of the previous one. The...
-
Lamp of adjustable spectrum for photographic usage
PublikacjaPhotography is a unique rapidly growing interdisciplinary field encompassing aspects of science, art and technology. Expectations of photographers are steadily increasing with the development of technology. One of the areas playing a crucial role in photography is lighting. Consequently, several types of light sources for photographic use have been developed. The ongoing research in this field concentrates on lamps with tunable...
-
Light box for investigation of characteristics of optoelectronics detectors
PublikacjaIn this paper, a light box for investigation of characteristics of optoelectronic detectors is described. The light box consists of an illumination device, an optical power sensor and a mechanical enclosure. The illumination device is based on four types of high-power light emitting diodes (LED): white light, red, green and blue. The illumination level can be varied for each LED independently by the driver and is measured by optical...
-
Measurement of luminance and color uniformity of displays using the large-format scanner
PublikacjaUniformity of display luminance and color is important for comfort and good perception of the information presented on the display. Although display technology has developed and improved a lot over the past years, different types of displays still present a challenge in selected applications, e.g. in medical use or in case of multi-screen installations. A simplified 9-point method of determining uniformity does not always produce...
-
Modeling of luminance distribution in CAVE-type virtual reality systems
PublikacjaAt present, one of the most advanced virtual reality systems are CAVE-type (Cave Automatic Virtual Environment) installations. Such systems are usually consisted of four, five or six projection screens and in case of six screens arranged in form of a cube. Providing the user with a high level of immersion feeling in such systems is largely dependent of optical properties of the system. The modeling of physical phenomena plays nowadays...
Rok 2015
-
ALD thin ZnO layer as an active medium in a fiber-optic Fabry-Perot interferometer
Publikacja.
-
DIFFRACTION PHASE MICROSCOPY FOR OBSERVATION ON RED BLOOD CELLS FLUCTUATION
PublikacjaNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – RBCs (Red Blood Cells). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations observation...
-
Luminance Distribution Measurements in CAVE-Type Virtual Reality Systems
PublikacjaIn this article, the immerse 3D visualization lab just opened at the Gdańsk University of Technology is presented. The effect of user “immersion,” it such virtual reality systems, is largely dependent on the optical properties of projected images. Luminance distribution of screens was measured and the luminance uniformity was determined and discussed.
-
Optoelectronic device for hematocrit measurements
PublikacjaAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Polarization interferometer using a Liquid Crystalline Polymer waveplate for wavelength measurement
PublikacjaA two-beam polarization interferometer for measuring wavelength changes of a tunable semiconductor laser was designed, built and tested. This interferometer uses a λ/8 waveplate made from Liquid Crystalline Polymer in order to generate two output signals in quadrature. The λ/8 waveplate can be manufactured either on a beamsplitter face or on the mirror surface, reducing the cost and complexity of the optomechnical assembly. Experiment...
Rok 2014
-
Image projection in Immersive 3D Visualization Laboratory
PublikacjaIn recent years, many centers in the world attempted to build a virtual reality laboratory. The main idea of such laboratory is to allow the user to “immerse” into and move in a computer-generated virtual world. In the paper, the underlying principles of the system of virtual reality (VR) are described. The selected implementations constructed by the research centers of the world are also presented. The cave automatic virtual environment...
-
Innovative Solutions for Immersive 3D Visualization Laboratory
PublikacjaThe paper presents results of the work concerning the technical specification of Immersive 3D Visualization Laboratory to be opened in late summer 2014 at the Faculty of Electronics, Telecommunications and Informatics at Gdańsk University of Technology in Poland. The person immersed in VR space will be placed in a transparent sphere with a diameter of over 10 feet, supported on rollers and equipped with a motion tracking system....
-
Launch of the Immersive 3D Visualization Laboratory
PublikacjaThe paper presents the concept of Immersive 3D Visualization Laboratory, formed at the Faculty of Electronics, Telecommunications and Informatics at Gdańsk University of Technology under the project Gdańsk University of Technology's Modern auditoriums. The basic unit of this laboratory will be cubic CAVE (Cave Automatic Virtual Environment) enriched with spherical walk simulator. This device will allow the user unlimited walking,...
-
Uruchomienie Laboratorium Zanurzonej Wizualizacji Przestrzennej
PublikacjaArtykuł przedstawia koncepcję Laboratorium Zanurzonej Wizualizacji Przestrzennej (ang. Immersive 3D Visualization Laboratory), powstającego właśnie przy Wydziale Elektroniki, Telekomunikacji i Informatyki (ang. Faculty of Electronics, Telecommunications and Informatics) Politechniki Gdańskiej (ang. Gdańsk University of Technology) w ramach grantu Nowoczesne Audytoria Politechniki Gdańskiej (ang. project Gdansk University of Technology’s...
Rok 2013
-
LZWP, czyli jak zbudować CAVE
PublikacjaReferat prezentuje wyniki prac autorów dotyczących specyfikacji technicznej instalacji typu CAVE tworzonej na Wydziale ETI Politechniki Gdańskiej. Przedstawiona analiza została dokonana na pod-stawie wiedzy autorów, studiów literaturowych, wizytacji wybranych instalacji w kraju i zagranicą oraz konsultacji z firmami będącymi wiodącymi producentami lub integratorami systemów 3D.
-
Measurements of Spectral Spatial Distribution of Scattering Materials for Rear Projection Screens used in Virtual Reality Systems
PublikacjaRapid development of computing and visualisation systems has resulted in an unprecedented capability to display, in real time, realistic computer-generated worlds. Advanced techniques, including three-dimensional (3D) projection, supplemented by multi-channel surround sound, create immersive environments whose applications range from entertainment to military to scientific. One of the most advanced virtual reality systems are CAVE-type...
Rok 2010
-
Immersive 3D visualization laboratory concept
PublikacjaArtykuł opisuje koncepcję realizowanego na Politechnice Gdańskiej urządzenia do marszu przez świat wirtualny. Będzie ono miało postać przezroczystej sfery obrotowej, którą użytkownik umieszczony w środku będzie obracał własnymi krokami (na wzór chomika biegnącego w kołowrotku). Sfera będzie umieszczona wewnątrz sześcianu zbudowanego z ekranów, na których będzie wyświetlany obraz stereoskopowy przedstawiający świat wirtualny z punktu...
-
Projekt laboratorium zanurzonej wizualizacji przestrzennej
PublikacjaArtykuł prezentuje koncepcję urządzenia pozwalającego na nieograniczony terytorialnie spacer po zadanym świecie wirtualnym, które ma zostać zrealizowane na Politechnice Gdańskiej do końca 2013 roku w specjalnie zbudowanym pawilonie. Urządzenie to będzie symulować autonomiczne przemieszczanie się wewnątrz sceny generowanej komputerowo. Wrażenie samodzielnego ruchu uzyskane zostanie poprzez zastosowanie mechanizmu pozwalającego na...
Rok 2009
-
Detection of thermal radiation using lanthanum-strontium-iron oxide (LSFO) bolometers
PublikacjaW artykule przedstawiono bolometr wykonany z tlenków lantanowo-strontowo-żelazowych zastosowany do detekcji promienowania podczerwonego. Parametry bolometru były badane za pomocą wzorcowego źródła poromieniowania o temperaturze 38°C (311 K) oddalonego od bolometru o 500 mm. W trakcie pomiarów uzyskano stosunek sygnał/szum wynoszący ok. 62 (tj. 35.9 dB). Na podstawie wyników pomiarów oszacowano dokładność pomiaru temperatury za...
Rok 2006
-
Eksperymentalna weryfikacja metody wielopasmowego pomiaru emisyjności
PublikacjaW pracy zaproponowano i opisano wielopasmową pasywną metodę pomiaru emisyjności obiektu. W oparciu o zrealizowane stanowisko pomiarowe dokonano pomiarów emisyjności wybranych obiektów. Uzyskano dobrą zgodność wyników pomiarów z wynikami wcześniejszej komputerowej analizy systemu. Potwierdziło to przydatność wielopasmowej metody do pomiaru emisyjności w warunkach roboczych.
-
Fluorescence Measurements for chemical optical sensor of cobalt
PublikacjaW pracy zaproponowano i opisano optoelektroniczny fluorescencyjny sensor do pomiaru stężenia kobaltu w wodzie.
-
Modeling of polarimetric sensors using LabVIEW environment
PublikacjaW artykule przedstawiono program do modelowania światłowodowych sensorów polarymetrycznych. Program ten, stworzony w środowisku LabVIEW, wyznacza odpowiedź nieidealnego światłowodowego sensora polarymetrycznego na siłę działającą na przetwornik pomiarowy. Omówiono problemy występujące w procesie tworzenia oprogramowania do modelowania zjawisk fizycznych w graficznym środowisku programistycznym. Przedstawiono wybrane wyniki modelowania.
-
Modelowanie światłowodowych sensorów polarymetrycznych za pomocą oprogramowania LabVIEW
PublikacjaW komunikacie opisano aplikację umożliwiającą modelowanie pracy polarymetrycznych sensorów światłowodowych. Aplikacja ta, napisana w oparciu o platformę LabVIEW, umożliwia wyznaczenie odpowiedzi rzeczywistego sensora polarymetrycznego wykorzystującego monochromatyczne źródło światła. Omówiono problemy występujące w tworzeniu aplikacji do modelowania w graficznym środowisku do tworzenia aplikacji i zaprezentowano wybrane wyniki...
-
Optoelektroniczne sensory fluorescencyjne dla monitoringu zanieczyszczeń środowiska
Publikacjaw pracy zaproponowano i opisano optoelektroniczny fluorescencyjny sensor do pomiaru stężenia kobaltu w wodzie. opisano zasadę działania tego typu sensorów. zaproponowano konfigurację laboratoryjnego stanowiska pomiarowego i przeprowadzono dobór niektórych jego komponentów. przedstawiono także etapy dalszych prac badawczych nad konstrukcją sensora.
-
Pomiary fluorescencji dla światłowodowych sensorów chemicznych
Publikacjaw pracy opisano zrealizowany układ do pomiaru fluorescencji materiałów sensorycznych. zaproponowano układ wykorzystujący rozdzielenie widma absorpcji i emisji promieniowania oraz detekcję fazoczułą. opisano sposób przygotowania badanych próbek, a także przeprowadzono pomiary wybranych związków chemicznych. uzyskane wyniki są podstawą do dalszych prac.
-
Verification of multiband system for non-contact emissivity measurements
PublikacjaW pracy przeprowadzono weryfikację wielopasmowej pasywnej metody pomiaru emisyjności obiektu na drodze eksperymentalnej. W oparciu o zrealizowane stanowisko pomiarowe dokonano pomiarów emisyjności wybranych obiektów. Uzyskano dobrą zgodność wyników pomiarów z wynikami wcześniejszej komputerowej analizy systemu. Potwierdziło to przydatność wielopasmowej metody do pomiaru emisyjności w warunkach roboczych.
Rok 2003
-
Experimental verification of multiband system of non coantact temperature measurements. IV Workshop on Atomic and Molecular Physics.
PublikacjaW pracy przedstawiono wielopasmowy optoelektroniczny system do bezkontaktowych pomiarów temperatury wykonane za jego pomocą w zakresie od 250 do 390 stopni Celsjusza. Przeprowadzono dyskusję błędów pomiarowych i porównano otrzymane rezultaty z wynikami modelowania komputerowego.
-
Metoda bezkontaktowego wielopasmowego pomiaru emisyjności.**2003, 100 s.30 rys. 6 tab. bibliogr. 86 poz. maszyn. Rozprawa doktorska /01.07.2003/ Wydz. ETI Promotor: prof. zw. dr hab. inż. K. Chrzanowski
PublikacjaW pracy omówiona została metoda bezkontaktowego wielopasmowego pomiaru emi-syjności. Przedstawiona została ogólna koncepcja systemu pomiarowego do bez-kontaktowych pomiarów emisyjności, a także opracowany został matematyczny o-pis elementów systemu. Dla wyznaczenia nieznanych wartości temperatury i e-misyjności obiektu na podstawie zgromadzonych danych pomiarowych wykorzysta-na została aproksymacja za pomocą liniowej metody najmniejszych...
-
Non contact multiband emissivity measurment. bibliogr.Optoelectronic and Electronic Sensors.
PublikacjaW pracy zaproponowano i opisano wielopasmowa pasywną metodę pomiaru emisyjności obiektu. W oparciu o opracowany model matematyczny przeprowadzona została analiza systemu pomiarowego. Wyniki modelowania umożliwiają ocenę dokładności projektowanego systemu.
-
Non contact multiband method for emissivity measurment.
PublikacjaW pracy omówiona została metoda bezkontaktowego wielopasmowgo pomiaru emisyjności. W oparciu o opracowany algorytm zbadany został wpływ poszczególnych elementów systemu i czynników zakłócających na dokładność wyznaczania emisyjności. Wyniki modelowania umożliwiają także ocenę dokładności całego systemu pomiarowego.
Rok 2002
-
Bezkontaktowe, wielopasmowe pomiary emisyjności
PublikacjaW pracy zaproponowano i opisano wielopasmową pasywną metodę do pomiaru emisyjności obiektu. Omówiono inne metody pomiaru emisyjności oraz przeprowadzono analizę systemu wielopasmowego. Wyniki modelowania umożliwiają ocenę dokładności projektowanego systemu.
wyświetlono 5274 razy