dr hab. inż. Agnieszka Tomaszewska
Zatrudnienie
- Kierownik katedry w Katedra Mechaniki Budowli
- Profesor uczelni w Katedra Mechaniki Budowli
Publikacje
Filtry
wszystkich: 56
Katalog Publikacji
Rok 2023
-
Biomechanical causes for failure of the Physiomesh/Securestrap system
PublikacjaThis study investigates the mechanical behavior of the Physiomesh/Securestrap system, a hernia repair system used for IPOM procedures associated with high failure rates. The study involved conducting mechanical experiments and numerical simulations to investigate the mechanical behavior of the Physiomesh/Securestrap system under pressure load. Uniaxial tension tests were conducted to determine the elasticity modulus of the Physiomesh...
-
Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.
Publikacjarepairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of highquality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. Method The authors conducted...
-
W poszukiwaniu równowagi: aplikacja do nauki analizy statycznej układów prętowych
PublikacjaPraca dotyczy interaktywnej aplikacji mającej wesprzeć naukę analizy statycznej układów prętowych. Aplikacja jest tworzona z myślą o studentach I roku budownictwa i kierunków pokrewnych. Wyznaczenie wykresów sił wewnętrznych jest podstawą procesu projektowania konstrukcji. Chociaż współcześnie stosuje się programy do komputerowej analizy konstrukcji, to projektant nadal musi potrafić zinterpretować wynik i ocenić jego poprawność....
Rok 2022
-
A novel in vivo approach to assess strains of the human abdominal wall under known intraabdominal pressure
PublikacjaThe study concerns mechanical behaviour of a living human abdominal wall. A better mechanical understanding of a human abdominal wall and recognition of its material properties is required to find mechanically compatible surgical meshes to significantly improve the treatment of ventral hernias. A non-invasive methodology, based on in vivo optical measurements is proposed to determine strains of abdominal wall corresponding to...
-
BJS-03 DO WE NEED FIXATION OF THE MESH IN LAPAROENDOSCOPIC TECHNIQUES FOR M3 INGUINAL DEFECTS? AN EXPERIMENTAL STUDY
PublikacjaThe authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. The results showed that mesh fixation is not the only alternative to preventing recurrence in complex defects and that the type of implant seems to be a key factor from the point of view of mechanics and biophysics.
-
Combined numerical and experimental approach to determine numerical model of abdominal scaffold
PublikacjaA proper junction of the prosthesis and the abdominal wall is important in successful hernia repair. The number of tacks should be balanced to assure appropriate mesh fixation and not to induce post-operative pain. Numerical simulations help to find this balance. The study is aimed at creating a proper numerical model of a knitted surgical mesh subjected to boundary conditions and load occurring in the abdominal cavity. Continuous,...
-
Consideration of the safety of bungee jumping in relation to mechanical properties of the instalation based on a jump accident in Gdynia
PublikacjaThis paper considers a bungee jumping accident that took place in July 2019 in Gdynia, Poland. The authors conducted an investigation to determine the cause of the bungee rope failure. It was based on mechanical tests concerning the strength of the rope as well as the calculation of the force induced in the rope during the jump. Based on the theoretical and experimental results, the rope safety factor was estimated. It appeared...
-
Vibration-Based Investigation of a Historic Bell Tower to Understand the Occurrence of Damage
PublikacjaABSTRACT The paper presents a survey of the historic Arch-cathedral bell tower in Vilnius induced by the appearance of cracks in the structure after a new bell system installation. An attempt is undertaken to identify the reason for the crack occurrence and to check a possible crack influence on global structural behaviour. The research is based on dynamic measurements made in the tower during ambient vibrations and during vibrations...
Rok 2020
-
Constitutive Modelling of Knitted Abdominal Implants in Numerical Simulations of Repaired Hernia Mechanics
PublikacjaThe paper presents a numerical approach to describe mechanical behavior of anisotropic textile material, which is a selected abdominal prosthesis. Two constitutive nonlinear concepts are compared. In the first one the material is considered composed from two families of threads (dense net model) and in the second one the material is homogeneous but anisotropic (as proposed by Gassel, Ogden, Holzapfel). Parameters of both models...
-
In vivo performance of intraperitoneal onlay mesh after ventral hernia repair
PublikacjaBackground: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures...
-
Material Parameters Identification of Historic Lighthouse Based on Operational Modal Analysis
PublikacjaIn the present paper, the identification of the material parameters of a masonry lighthouse is discussed. A fully non-invasive method was selected, in which the material properties were determined via numerical model validation applied to the first pair of natural frequencies and their related mode shapes, determined experimentally. The exact structural model was built by means of the finite element method. To obtain experimental...
-
Study on applicability of two modal identification techniques in irrelevant cases
PublikacjaStudy on applicability of two modal identification techniques in irrelevant cases is made in this paper. The following techniques are considered: Peak Picking based on correlation analysis (PP-CA), dedicated for ambient vibrations and Eigensystem Realization Algorithm (ERA), formulated for free decay vibrations investigation. Irrelevant cases are found when analyzed signals are different than recommended to a given technique. The...
Rok 2019
-
Jaw biomechanics: Estimation of activity of muscles acting at the temporomandibular joint
PublikacjaThe aim of this study was to elaborate a method of estimation of activity of surface muscles acting at the temporomandibular joint of the healthy subjects by using a surface electromyography (EMG). The scope of this study involved testing chosen jaw motions (open, close, lateral deviation) and process of mastication occurring during eating food with different toughness (chewing gum, cereal and carrot) by using mixed sides, right...
-
Mechanics of mesh implanted into abdominal wall under repetitive load. Experimental and numerical study
PublikacjaThere are a number of papers discussing medical and mechanical aspects of ventral hernia management. Despite intensive work on the problem understanding, recurrences of the sickness still happen too often. For that reason new aspects of the problem must be considered. In this paper, a change in the abdominal implant’s stiffness is discussed, which is caused by cyclic loading. Such loading influence abdominal implant e.g. while...
-
Stiffness change of abdominal prosthesis Optomesh™ under cyclic loading
PublikacjaAbdominal prostheses are used in humans for abdominal wall strengthening or reconstruction. From the mechanical point of view they are membranes, so their basic mechanical property is tensile stiffness. This property is experimentally identified for a selected implant, OptomeshTM. The obtained results are described herein. Uni-axial simple and cyclic tension tests are a basis for the analysis. Both kinds of tests allowed to distinguish...
Rok 2018
-
Membrane model of human abdominal wall. Simulations vs. in vivo measurements
PublikacjaThe study presents a methodology of defining a numerical model of human abdominal wall based on the experimentally registered data of the abdomen geometry due to variations of the intraabdominal pressure. The abdominal wall is modelled here as a simple homogeneous membrane structure made of linear orthotropic material The displacements registered during the increase of pressure are compared with the re-sults of the model static...
-
Opracowanie dotyczące pomiarów odkształceń oraz analizy wytrzymałościowej systemu wsporczego WS007 przy obciążeniu statycznym
PublikacjaOpracowanie dotyczące pomiarów odkształceń oraz analizy wytrzymałościowej systemu wsporczego WS007 przy obciążeniu statycznym
-
Towards Understanding of Mechanics of Hernia Managed by Synthetic Mesh in Laparoscopic Operation: A Single Case Study
PublikacjaIn this paper a research towards understanding of mechanics of ventral hernia operated with the use of Physiomesh Open image in new window implant and SecureStrap Open image in new window staples is described. Experimental and numerical studies are conducted for that purpose. Experimental works cover uni-axial tension tests of the implant samples and of the implant-staples-tissue system. Also experiments on implant-staples-tissue...
Rok 2017
-
Two-criteria optimisation problem for ventral hernia repair
PublikacjaTwo-criteria optimisation problem related to laparoscopic ventral hernia repair is formulated in this paper. An optimal implant from a given set and its orientation is sought. The implant is subjected to kinematic extortions due to a patient’s body movement and intra-abdominal pressure. The first criterion of the optimisation problem deals with the reaction force in the implant fastener, while the deflection of the implant constitutes...
Rok 2016
-
A PRELIMINARY STUDY ON THE OPTIMAL CHOICE OF AN IMPLANT AND ITS ORIENTATION IN VENTRAL HERNIA REPAIR
PublikacjaThis paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic...
wyświetlono 2804 razy