mgr inż. Bartłomiej Piotr Prowans
Zatrudnienie
Obszary badawcze
- Brak danych
-
FTIR (Fourier-transform infrared spectroscopy) spectra of titanium dioxide coated nickel foams.
Dane BadawczeThis dataset contains FTIR spectra recorded on a JASCO 4200 spectrometer of nickel foams coated with titanium dioxide after heating at 400, 500 and 600 C and after photocatalytic process with NOx.
-
XRD (X-ray Diffraction) of titanium dioxide coated nickel foams
Dane BadawczeThese data include XRD patterns of titanium dioxide coated nickel foams heated at 400, 500 and 600C in argon atmosphere.
-
UV/VIS Spectroscopy of titanium dioxide coated nickel foams
Dane BadawczeThe data includes UV-Vis spectra of titanium dioxide coated nickel foams heated at 400, 500 and 600 C in Ar. Jasco V-650 Spectrophotometer was used and Spectra Measurement software.
-
XPS (X-ray photoelectron spectroscopy) of titanium dioxide coated nickel foams and heated 400,500, 600C
Dane BadawczeThis data set contains XPS spectra recorded for nickel foams coated with titanium dioxide and heated at 400, 500 and 600 degrees celcius.
-
Phototcatalytic oxidation of NO on titanium dioxide coated nickel foams
Dane BadawczeThe results of photocatalytic NO oxidation were compiled in an Excel file. The measurement was carried out using a chemiluminescence NO analyzer.
-
BET (Brunauer-Emmett-Teller) surface area analysis of titanium dioxide coated nickel foams
Dane BadawczeThe data are presented for the BET surface results of nickel foams coated with titanium dioxide and heated 400, 500 and 600 degrees Celsius in an argon atmosphere. N2 sorption was performed at 77 K pore size distribution was determined by BJH and DFT methods.
-
SEM-EDS images of expanded polystyrene spheres coated with silicon dioxide (SiO2) and/or titanium dioxide (TiO2)
Dane BadawczeData contain SEM and SEM-EDS images of expanded polystyrene spheres coated with silicon dioxide (SiO2) and/or titanium dioxide (TiO2). The detailed equipment and measurement data was described in measurement info.txt file.
-
Light transmission measurement through the fluidized bed photoreactor
Dane BadawczeDataset contains light transmission measurements through the fluidized bed photoreactor. Two sources of light were used: UV-LEDs and UV fluorescent. Measurements were performed at different air flows: 0, 80, 160 and 240 ml/min. The detailed measurement and equipment data was described in measurment info.txt file.
-
Photocatalytic ethylene decomposition with the use of fluidized bed photoreactor
Dane BadawczeData contain exported raw data recorded during decomposition of ethylene during utilization of fluidized bed photoreactor equipped with either UV-LEDs or fluorescent UV lamps as well as in either humid or dry conditions. In separate folder, the photographs of the photocatalytic system were included. As photocatalytic material, polystyrene spheres coated...
wyświetlono 518 razy