Biotrickling filtration of air polluted with hexane and cyclohexane: effects of trickling liquid modification with DES solutions

Opis

Dataset presents selected parameters monitored during processes of biotrickling filtration of air polluted with hexane and cyclohexane.

Following results are presented:

a. Effects of trickling liquid composition on changes of optical density (OD) values;

b. Influence of trickling liquid composition on the changes of its pH value;

c. Effects of DES addition on the surface tension of trickling liquid;

d. Effects of DES addition on the zeta potential of particles from trickling liquid suspension;

e. Performance of biotrickling filtration of air polluted with hexane and cyclohexane with trickling liquid without DES modification - biotrickling filter A;

f. Performance of biotrickling filtration of air polluted with hexane and cyclohexane with trickling liquid with DES1 additive (3% v/v; DES1: choline chloride : ethylene glycol) - biotrickling filter B;

g. Performance of biotrickling filtration of air polluted with hexane and cyclohexane with trickling liquid with DES2 additive (3% v/v; DES2: L-carnitine : C-8 acid) - biotrickling filter C.

OD values were determined spectrophotometrically (Shimadzu UV-3600). pH values were measured using Voltcraft pH-100 ATC pH-meter. Surface tension was measured using Kruss K10 tensiometer. Zeta potential was determioned using Malvern ZetaSizer Nano ZS. 

Biotrickling filtration experiments were run in counter-current plexiglass biotrickling filters, packed with polyurethane foam discs, inoculated with Candida subhashii prior to starting the experiments. Biofilters were run at empty bed residence time of 60s. Biofilters were fed with a mixture of hexane and cyclohexane (1:1 v/v), the results are presented for hexane. Concentrations of hexane and cyclohexane at the inlet and outlet of biotrickling filters were determined using Varian CP-3800 gas chromatograph equipped with a flame ionization detector.

Plik z danymi badawczymi

Dataset 4.zip
250.7 kB, S3 ETag 91bf4da0c41d3c09714e9499d9f2b5cb-1, pobrań: 74
Hash pliku liczony jest ze wzoru
hexmd5(md5(part1)+md5(part2)+...)-{parts_count} gdzie pojedyncza część pliku jest wielkości 512 MB

Przykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5
pobierz plik Dataset 4.zip

Informacje szczegółowe o pliku

Licencja:
Creative Commons: by-nc 4.0 otwiera się w nowej karcie
CC BY-NC
Użycie niekomercyjne

Informacje szczegółowe

Rok publikacji:
2023
Data zatwierdzenia:
2023-01-13
Data wytworzenia:
2022
Język danych badawczych:
angielski
Dyscypliny:
  • inżynieria chemiczna (Dziedzina nauk inżynieryjno-technicznych)
  • nauki chemiczne (Dziedzina nauk ścisłych i przyrodniczych)
DOI:
Identyfikator DOI 10.34808/rpmy-tx79 otwiera się w nowej karcie
Finansowanie:
Weryfikacja:
Politechnika Gdańska

Słowa kluczowe

Cytuj jako

wyświetlono 150 razy