The aggregation of objects representing Gdańsk district buildings - scale 1:25000 - Open Research Data - MOST Wiedzy

Wyszukiwarka

The aggregation of objects representing Gdańsk district buildings - scale 1:25000

Opis

The process of automatic generalization is one of the elements of spatial data preparation for the purpose of creating digital cartographic studies. The presented data include a part of the process of generalization of building groups obtained from the national geodesy and cartography resource from BDOT10k (10k topographic database) [1].

The data include the spatial scope of Gdańsk district. In the city, there are buildings of each class according to the BDOT10k classification. Single-family residential buildings constitute 47% of all buildings, buildings with three or more apartments 18%, farm buildings 15%, each of the remaining classes contains less than 4%.

The provided data include original data downloaded from geoportal.gov.pl (on 6 November 2020) [2] as well as processed data. The aggregation process was performed taking into account the proximity of the neighborhood [3] based on the minimum size of the figure [4, 5]. The data are the basis for the subsequent steps in the process of sequential generalization of building groups.

Literature

[1] Regulation of the Ministry of Administration and Digitization, W sprawie bazy danych obiektów topograficznych oraz bazy danych obiektów ogólnogeograficznych,

a także standardowych opracowań kartograficznych [Regarding the database of topographic objects and the database of general geographic objects, as well as standard cartographic studies.]

[2] www.geoportal.gov.pl [access: 06.11.2020].

[3] Kozioł, Krystian, and Michał Lupa. "The use of merging and aggregation operators for MRDB data feeding." Geoinformatica Polonica 12 (2013): 17-24.

[4] Chrobak, Tadeusz. Badanie przydatności trójkąta elementarnego w komputerowej generalizacji kartograficznej. Uczelniane Wydawnictwa Naukowo-Dydaktyczne AGH, 1999.

[5] Chrobak, Tadeusz, et al. "A method for assessing generalized data accuracy with linear object resolution verification." Geocarto International 32.3 (2017): 238-256.

Plik z danymi badawczymi

GDA_k25_BuildingAggregation.zip
8.9 MB, S3 ETag 43d87186c185834b6b2102fd3f35c3ab-1, pobrań: 64
Hash pliku liczony jest ze wzoru
hexmd5(md5(part1)+md5(part2)+...)-{parts_count} gdzie pojedyncza część pliku jest wielkości 512 MB

Przykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5
pobierz plik GDA_k25_BuildingAggregation.zip

Informacje szczegółowe o pliku

Licencja:
Creative Commons: by 4.0 otwiera się w nowej karcie
CC BY
Uznanie autorstwa

Informacje szczegółowe

Rok publikacji:
2021
Data zatwierdzenia:
2021-04-27
Data wytworzenia:
2021
Język danych badawczych:
angielski
Dyscypliny:
  • Inżynieria lądowa i transport (Dziedzina nauk inżynieryjno-technicznych)
DOI:
Identyfikator DOI 10.34808/wnpf-p026 otwiera się w nowej karcie
Seria:
Weryfikacja:
Politechnika Gdańska

Słowa kluczowe

Powiązane zasoby

Cytuj jako

wyświetlono 109 razy