The SEM micrographs of the cavitation erosion-corrosion process of selected copper alloys degradation
Opis
The dataset contains Scanning Electron Micrographs of CuZn40Mn3Fe brass compared with Superston and Novoston bronze after cavitation erosion-corrosion exposure using a vibratory transducer (in accordance with ASTM G32). The micrographs compare the topography of samples subjected cavitation erosion in 3% NaCl at room temperature, leading to the surface deformation combined with intergranular corrosion. The micrographs were taken after various exposure duration between 10 and 240 min, labeled accordingly, with cyclic cavitation exposure in on/off cycles 60s:60s. The samples were mounted directly underneath the ultrasonic transducer. More details on the experiment are to be found in: 10.1016/j.electacta.2016.01.216
Plik z danymi badawczymi
SEM.Cu.zip
114.0 MB,
S3 ETag
e7793f8fc802a9d7d932ef936e0fc7aa-1,
pobrań: 71
Hash pliku liczony jest ze wzoru
Przykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
gdzie pojedyncza część pliku jest wielkości 512 MBPrzykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5
Informacje szczegółowe o pliku
- Licencja:
-
otwiera się w nowej karcieCC BYUznanie autorstwa
- Dane surowe:
- Dane zawarte w datasecie nie zostały w żaden sposób przetworzone.
Informacje szczegółowe
- Rok publikacji:
- 2016
- Data zatwierdzenia:
- 2021-04-28
- Język danych badawczych:
- angielski
- Dyscypliny:
-
- nauki chemiczne (Dziedzina nauk ścisłych i przyrodniczych)
- inżynieria mechaniczna (Dziedzina nauk inżynieryjno-technicznych)
- inżynieria materiałowa (Dziedzina nauk inżynieryjno-technicznych)
- DOI:
- Identyfikator DOI 10.34808/vncn-rk05 otwiera się w nowej karcie
- Weryfikacja:
- Politechnika Gdańska
Słowa kluczowe
Powiązane zasoby
Cytuj jako
Autorzy