A pilot study with flow mediated skin fluorescence: A novel device to assess microvascular endothelial function in coronary artery disease - Publikacja - MOST Wiedzy

Wyszukiwarka

A pilot study with flow mediated skin fluorescence: A novel device to assess microvascular endothelial function in coronary artery disease

Abstrakt

Background: Endothelial dysfunction is one of the earliest vascular manifestations in the pathogenesis of cardiovascular disease. Noninvasive, simple and inexpensive methods of endothelial function assessment are therefore needed. Methods: Microvascular endothelial function was assessed in coronary artery disease (CAD) patients by flow mediated skin fluorescence (FMSF), based on measurements of NADH fluorescence intensity during brachial artery occlusion (ischemic response [IRmax]) and immediately after occlusion (hyperemic response [HRmax]). Additionally, plasma levels of asymmetric dimethylarginine (ADMA) and endothelin-1 (ET-1) were measured to assess the association between biochemical markers and microvascular function evaluated in vivo by FMSF. Results: A significant inverse correlation was found between ADMA levels and hyperemic response (r = –0.534, p = 0.003), while ET-1 levels were inversely related to the ischemic response (r= –0.575, p = 0.001). Both IR and HR were found lowest in patients with advanced CAD and diabetes. When the repeatability of the method was tested, the intraclass correlation coefficient for IRmax and HRmax were 0.985 (p < 0.001) and 0.914 (p < 0.001), respectively. Moreover, in Bland and Altman analysis, both variables IRmax and HRmax showed good agreement in repeated measurements. Conclusions: In this pilot study, it was demonstrated that NADH fluorescence measured by FMSF device in CAD patients was associated with established plasma endothelial markers, and that both ischemic and hyperemic response were blunted in patients with advanced disease and diabetes. Furthermore, FMSF device showed excellent repeatability and good agreement for repeated measurements. However, further study is warranted to confirm these results in a larger patient cohort.

Cytowania

  • 1 8

    CrossRef

  • 0

    Web of Science

  • 2 3

    Scopus

Autorzy (5)

Cytuj jako

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuł w czasopiśmie wyróżnionym w JCR
Opublikowano w:
Cardiology Journal nr 25, strony 120 - 127,
ISSN: 1897-5593
Język:
angielski
Rok wydania:
2018
Opis bibliograficzny:
Tarnawska M., Dorniak K., Kaszubowski M. F., Dudziak M., Hellmann M.: A pilot study with flow mediated skin fluorescence: A novel device to assess microvascular endothelial function in coronary artery disease// Cardiology Journal. -Vol. 25, iss. 1 (2018), s.120-127
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.5603/cj.a2017.0096
Weryfikacja:
Politechnika Gdańska

wyświetlono 151 razy

Publikacje, które mogą cię zainteresować

Meta Tagi