Analysis of the effect of the seismic gap on the response of buildings experiencing pounding during earthquakes - Publikacja - MOST Wiedzy

Wyszukiwarka

Analysis of the effect of the seismic gap on the response of buildings experiencing pounding during earthquakes

Abstrakt

The aim of this paper is to investigate the effect of the seismic gap on the dynamic response of buildings experiencing earthquake-induced pounding. Three buildings have been analysed, which are 5-storey, 7-storey and 9-storey structures. Three possible pounding scenarios have been considered, which are pounding between 5-storey and 7-storey buildings, pounding between 5-storey and 9-storey buildings and pounding between 7-storey and 9-storey buildings. Three seismic gaps between these three buildings have been investigated, which are 1 mm (contact structures), 2 cm and 2 m (separated structures). The results of the study show that the acceleration and pounding force time histories are significantly affected by the seismic gap. Moreover, not necessarily smaller gaps lead to smaller accelerations and pounding forces. It has been observed that the response is larger for small gaps in certain cases, while the response is larger for large gaps in other cases. This means that increasing the gap will not reduce the response unless it is large enough to eliminate collisions.

Cytowania

  • 2

    CrossRef

  • 0

    Web of Science

  • 1

    Scopus

Cytuj jako

Pełna treść

pełna treść publikacji nie jest dostępna w portalu

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuły w czasopismach
Opublikowano w:
AIP Conference Proceedings nr 2848,
ISSN: 0094-243X
Język:
angielski
Rok wydania:
2023
Opis bibliograficzny:
Miari M., Jankowski R.: Analysis of the effect of the seismic gap on the response of buildings experiencing pounding during earthquakes// AIP Conference Proceedings -Vol. 2848,iss. 1 (2023), s.020021-
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1063/5.0145034
Źródła finansowania:
  • The amount reported is in EUR. The fee on the invoice is 130 EUR funded by the Department of Building Engineering, Faculty of Civil and Environemtnal Engineering.