Dew and hoarfrost frequency, formation efficiency and chemistry in Wroclaw, Poland - Publikacja - MOST Wiedzy

Wyszukiwarka

Dew and hoarfrost frequency, formation efficiency and chemistry in Wroclaw, Poland

Abstrakt

This article presents the results of a research study concerning a comparison of frequency, formation efficiency and basic physico-chemical properties of dew and hoarfrost in urban conditions. Longer than two-year series of measurements was carried out from 1 February 2008 to 10 March 2010 in Wroclaw, Poland. Sampling of atmospheric deposits was made by means of insulated plain passive radiative condensers, which allowed to collect 222 dew and 96 hoarfrost samples. The results indicate that the frequency of dew days was about threefold greater than hoarfrost days. The formation efficiency of both types of deposits was almost the same, and reached a mean value of about 100 mL·m−2 per day. The conducted analysis of several meteorological parameters showed that dew and hoarfrost, despite seasonal weather changes, were formed in very similar meteorological conditions. Only water vapor pressure values were in average twice higher in the case of dew and the impact of this parameter on dew and hoarfrost formation efficiency seems to be more complex than expected. The role of night duration in counterbalancing of smaller amount of available moisture in hoarfrost days is not clear. The investigation showed also, that there was an expected clear positive dependence of dew and hoarfrost formation efficiency on relative humidity, and not so evident in the case of temperature inversion, and wind velocity. The physico-chemical analysis indicated that the pH of dewwas only slightly lower than the hoarfrost ones, regardless of the deposit formation intensity. Simultaneously, the lower pH values were much more frequent in the case of dew, which resulted from more effective absorption of anthropogenic NO3 − and SO4 2− ions. For both types of deposits, the average pH was low (4.5–4.8) in relation to majority of studies reported in literature. In spite of seasonal changes of pollutant concentration, variousweather conditions and different mechanisms of pollutant absorption of dew and hoarfrost were characterized with almost identical, relatively lowcontamination—electric conductivity: 42 μS·cm−1. The dominant ions were: Ca2+, SO4 2−, NO3−, as well as Cl− (hoarfrost only), all of them predominantly of anthropogenic origin.

Cytowania

  • 1 6

    CrossRef

  • 0

    Web of Science

  • 2 3

    Scopus

Autorzy (6)

Cytuj jako

Pełna treść

pełna treść publikacji nie jest dostępna w portalu

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuł w czasopiśmie wyróżnionym w JCR
Opublikowano w:
ATMOSPHERIC RESEARCH nr 151, strony 120 - 129,
ISSN: 0169-8095
Język:
angielski
Rok wydania:
2015
Opis bibliograficzny:
Gałek G., Sobik M., Błaś M., Polkowska Ż., Cichała-Kamrowska K., Wałaszek k.: Dew and hoarfrost frequency, formation efficiency and chemistry in Wroclaw, Poland// ATMOSPHERIC RESEARCH. -Vol. 151, (2015), s.120-129
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1016/j.atmosres.2014.05.006
Weryfikacja:
Politechnika Gdańska

wyświetlono 148 razy

Publikacje, które mogą cię zainteresować

Urban dew formation efficiency and chemistry in Poland

  • G. Gałek,
  • M. Sobik,
  • M. Błaś
  • + 2 autorów
2016

Dew Formation and Chemistry Near a Motorway in Poland

  • G. Gałek,
  • M. Sobik,
  • M. Błaś
  • + 2 autorów
2012

Pollutant deposition via dew in urban and rural environment, Cracow, Poland

  • P. Muskała,
  • M. Sobik,
  • M. Błaś
  • + 2 autorów
2015
Meta Tagi