Abstrakt

In laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element Method. Two models are analysed: in the first one interaction between the mesh and a fascia is taken into account, in the second this interaction is not considered. Computations are conducted for two different material types of the implants: one with isotropic properties and second one with orthotropic properties. The models are validated by comparing dynamic numerical analysis with experimental outcomes, where load was simulating intraabdominal pressure during postoperative cough. Due to displacements of joints during activities like bending sideways or torsion of an abdomen, influence of kinematic extortions on forces in the joints is analysed. The outcome shows that position of the orthotropic implants is crucial and may strongly change the level of forces in the joints

Cytowania

  • 0

    CrossRef

  • 0

    Web of Science

  • 6

    Scopus

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuł w czasopiśmie wyróżnionym w JCR
Opublikowano w:
Acta of Bioengineering and Biomechanics nr 15, strony 89 - 96,
ISSN: 1509-409X
Język:
angielski
Rok wydania:
2013
Opis bibliograficzny:
Szepietowska K., Lubowiecka I.: Mechanical behaviour of the implant used in human hernia repair under physiological loads// Acta of Bioengineering and Biomechanics. -Vol. 15, nr. 3 (2013), s.89-96
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.5277/abb130311
Bibliografia: test
  1. DEEKEN C.R., ABDO M.S., FRISELLA M.M., MATHEWS B.D., Physicomechanical evaluation of absorbable and nonab- sorbable barrier composite meshes for laparoscopic ventral hernia repair, Surg. Endosc., 2011, Vol. 25, 1541-1522. otwiera się w nowej karcie
  2. SABERSKI E.R., ORENSTEIN S.B., NOVITSKY Y.W., Aniso- tropic evaluation of synthetic surgical meshes, Hernia, 2011, Vol. 15, 47-52. otwiera się w nowej karcie
  3. TWARDOWSKI Z.J., KSANNA R., NOSPS K.D., Intraabdominal pressures during natural activities in patients treated with CAPD, Nephron, 1986, Vol. 44, 129-135. otwiera się w nowej karcie
  4. SZYMCZAK C., LUBOWIECKA I., TOMASZEWSKA A., ŚMIETAŃSKI M., Modeling of the fascia-mesh system and sensitivity analysis of a junction force after a laparoscopic ventral hernia repair, Journal of Theoretical and Applied Mechanics, 2010, Vol. 48(4), 993-950.
  5. LUBOWIECKA I., WOŹNICA K., FEM modelling of membrane structure in human hernia repair, CMM 2011, 9-12 May 2011, Warsaw, Poland. otwiera się w nowej karcie
  6. SZEPIETOWSKA K, Numerical simulation of membrane struc- ture used in the treatment of abdominal hernia, Aktualne Problemy Biomechaniki, 2011, Vol. 5, 159-164, (in Polish).
  7. TOMASZEWSKA A., LUBOWIECKA I., SZYMCZAK CZ., ŚMIETAŃSKI M., KŁOSOWSKI P., MERONK B., BURY K., Experi- ments and simulations for laparoscopic ventral hernia repair improvement, Journal of Biomechanics, 2012, Vol. 45(Sup1), S346. otwiera się w nowej karcie
  8. LUBOWIECKA I., Dynamics of Mechanical Model of Implant- Tissue System in Ventral Hernia Repair, Vibrations in Physi- cal Systems, 2012, Vol. 25, 261-266.
  9. HERNÁNDEZ-GASCÓN B., ESPÉS N., PEÑA E., PASCUAL G., BELLÓN J.M., CALVO B., Computational framework to model and design surgical meshes for hernia, Computer Methods in Biomechanics and Biomedical Engineering, 2012, DOI: 0.10.80/10255842.2012.736967. otwiera się w nowej karcie
  10. WOJNICZ W., WITTBRODT E., Analysis of muscles behaviour. Part I. The computational model of muscle, Acta of Bioengi- neering and Biomechanics, 2009, Vol. 11(4), 15-21. otwiera się w nowej karcie
  11. WOJNICZ W., WITTBRODT E., Analysis of muscles' behaviour. Part II. The computational model of muscle's group acting on the elbow joint, Acta of Bioengineering and Biomechanics, 2010, Vol. 12(1), 3-10. otwiera się w nowej karcie
  12. WOJNICZ W., WITTBRODT E., Application of muscle model to the musculoskeletal modeling, Acta of Bioengineering and Biomechanics, 2012, Vol. 14(3), 29-39.
  13. HERNÁNDEZ-GASCÓN B., MENA A., PEÑA E., PASCUAL G., BELLÓN J.M., CALVO B., Understanding the Passive Me- chanical Behavior of the Human Abdominal Wall, Annals of Biomedical Engineering, 2013, Vol. 41(2), 433-444. otwiera się w nowej karcie
  14. GRÄßEL D., PRESCHER A., FITZEK S., graf v. KEYSERLINGK D., AXER H., Anisotropy of Human Linea Alba: A Biomechanical Study, Journal of Surgical Research, 2005, Vol. 124, 118-125. otwiera się w nowej karcie
  15. JUNGE K., KLINGE U., PRESCHER A., GIBONI P., NIEWIERA M., SCHUMPELICK V., Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants, Hernia, 2001, Vol. 5, 113-118.
  16. PODWOJEWSKI F., OTTÉNIO M., BEILLAS P., GUÉRIN G., TURQUIER F., MITTON D., Mechanical response of animal abdominal wall in vitro: Evaluation of the influence of a hernia defect and a repair with a mesh implanted intra- peritoneally, Journal of Biomechanics, 2013, Vol. 46(3), 561-566. otwiera się w nowej karcie
  17. HERNÁNDEZ-GASCÓN B., PEÑA E., PASCUAL G., RODRÍGEZ M., CALVO B., DOBLARÉ M.P., BELLÓN J.M., Mechanical and histological characterization of the abdominal muscle. A previous step to modelling hernia surgery, Journal of the Mechanical Behaviour of Biomedical Materials, 2011, Vol. 4, 392-404.
  18. RUTKOWSKA-KUCHARSKA A., SZPALA A., PIECIUK E., Sym- metry of muscle activity during abdominal exercises, Acta of Bioengineering and Biomechanics, 2009, Vol. 11(1), 25-30. otwiera się w nowej karcie
  19. HERNÁNDEZ-GASCÓN B., PEÑA E., MELERO H., PASCUAL G., DOBLARÉ M., GINEBRA M.P., BELLÓN J.M., CALVO B., Me- chanical behaviour of synthetic surgical meshes: Finite ele- ment simulation of the herniated abdominal wall, Acta Bio- materialia, 2011, 3905-3913. otwiera się w nowej karcie
  20. ŻAK M., KUROPKA P., KOBIELARZ M., DUDEK A., KALETA- KURATEWICZ K., SZOTEK S., Determination of the mechani- cal properties of the skin of pig foetuses with respect to its structure, Acta of Bioengineering and Biomechanics, 2011, Vol. 13(2), 37-43.
  21. SZYMCZAK C., LUBOWIECKA I., TOMASZEWSKA A., ŚMIETAŃSKI M., Investigation of abdomen surface deforma- tion due to life excitation: Implications for implant selection and orientation in laparoscopic ventral hernia repair, Clinical Biomechanics, 2012, Vol. 27, 105-110. otwiera się w nowej karcie
  22. ŚMIETAŃSKI M., BURY K., TOMASZEWSKA A., LUBOWIECKA I., SZYMCZAK Cz., Biomechanics of the front abdominal wall as a potential factor leading to recurrence with laparoscopic ventral hernia repair, Surg. Endosc., 2012, Vol. 26, 1461- 1467. otwiera się w nowej karcie
  23. ANUROV M.V., TIKOVA S.M., OETTINGER A.P., Biomechani- cal compatibility of surgical mesh and fascia being rein- forced: dependence of experimental hernia defect repair re- sults on anisotropic surgical mesh positioning, Hernia, 2012, Vol. 16, 199-210. otwiera się w nowej karcie
  24. MSC.Marc ® Mentat ® Help Reference.
  25. SZYMCZAK C., ŚMIETAŃSKI M., Selected problems of laparo- scopic ventral hernia repair -modeling and simulation, Alfa-Medica Press, Gdańsk, 2012 otwiera się w nowej karcie
  26. KOŁAKOWSKI Z., Podstawy wytrzymałości i stateczności płytowych konstrukcji kompozytowych, Politechnika Łódzka, Łódź 2008.
  27. LUBOWIECKA I., Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair, TASK Quarterly, 2012, Vol. 16(1), 23-31.
  28. SZEPIETOWSKA K., Mechanical modelling of implant used in the treatment of abdominal hernias, Master's Thesis, Gdańsk University of Technology, 2012, Gdańsk, (in Polish).
  29. LUBOWIECKA I., Behaviour of orthotropic surgical im- plant in hernia repair due to material orientation and abdomen surface deformation, Computer Methods in Biomechanics and Biomedical Engineering, 2013, DOI: 10.1080/10255642.2013.789102. otwiera się w nowej karcie